510(k) · Cleared
ClearedTED 191
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Teledyne Brown Engineering · CCL Analyzer, Gas, Oxygen, Gaseous-Phase
Cleared on Nov 13, 1997 after a 456-day review. FDA’s file for it is a 510(k) statement, which names no predicate.
- Decided
- Nov 13, 1997
- Review
- 456 days
- Class
- Class II
- Product code
- CCL
- Recalls
- None
- Predicates
- 0
FDA’s file for it is a 510(k) statement, which names no predicate.
Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in CCL? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new CCL device
- #1 K261389 PRO2 Elite Plus Oxygen Analyzer (PRO2PLUS-1)score 12.7 · 4 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA’s file for it is a 510(k) statement, which names no predicate.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All CCL devicesCCL Analyzer, Gas, Oxygen, Gaseous-Phase: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · CCL
2in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · CCL
Too few CCL 510(k)s in any year since 2007 to give a median.
Recalls per year · CCL
1in 2009
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · CCL
2in 2025
MAUDE reports naming product code CCL, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 2 | — | 0 | 1 |
| 2008 | 2 | — | 0 | 2 |
| 2009 | 0 | — | 1 | 2 |
| 2010 | 0 | — | 0 | 5 |
| 2011 | 1 | — | 0 | 4 |
| 2012 | 0 | — | 0 | 5 |
| 2013 | 2 | — | 0 | 3 |
| 2014 | 0 | — | 0 | 8 |
| 2015 | 0 | — | 0 | 5 |
| 2016 | 1 | — | 0 | 1 |
| 2017 | 0 | — | 0 | 2 |
| 2018 | 1 | — | 0 | 1 |
| 2019 | 0 | — | 0 | 1 |
| 2020 | 0 | — | 0 | 1 |
| 2021 | 0 | — | 0 | 3 |
| 2022 | 2 | — | 0 | 0 |
| 2023 | 1 | — | 0 | 4 |
| 2024 | 0 | — | 0 | 4 |
| 2025 | 2 | — | 0 | 2 |
| 2026 | 1 | — | 0 | — |
What is it indicated for?
The Teledyne TED 191 oxygen monitor is designed to accurately measure, display, and monitor the actual oxygen concentration present in a defined gaseous environment, either static or dynamic (i.e. either a gas stream or an enclosed body of gas). The device is primarily intended for use in medical applications such as oxygen therapy and ventilatory monjtoring, although it may be used in ancillary applications such as checking the purity of compressed air and oxygen, or mixes thereof.
Indications for use read by OCR from a scanned FDA 510(k) statement, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K963177 · printed Nov 6, 2026