510(k) Report

510(k) · Cleared

Cleared

Incstar Toxoplasma Igg Fast Elisa Assay (Cat.#7560)

K963297510(k) TraditionalCleared Dec 16, 1996117-day reviewClass II21 CFR 866.3780

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Incstar Corp. · LGD Enzyme Linked Immunoabsorbent Assay, Toxoplasma Gondii

Cleared on Dec 16, 1996 after a 117-day review. The summary cites one number, which could not be confirmed as its predicate (see the table below).

Decided
Dec 16, 1996
Review
117 days
Class
Class II
Product code
LGD
Recalls
None
Predicates
1

The summary cites one number, which could not be confirmed as its predicate (see the table below).

FIG. 1 — Lineage of K963297Source: FDA 510(k) database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LGD? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LGD device

  1. #1 K242022 Access Toxo IgGscore 9.7 · 3 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary; numbers the summary cites that cannot be its predicate are marked – and kept off the family tree.

TypeNumberDeviceApplicantDecidedRecalls
Kept off the family treeK915839Gull Toxoplasma IgG ELISA test
Not in FDA’s 510(k), De Novo or PMA lists as we hold them (a misreading, a typo, or a number FDA does not list), so it is kept off the family tree
Summary page 2
…e solid phase. SAFETY AND EFFECTIVENESS: The INCSTAR Toxoplasma IgG “fast” ELISA Kit is substantially equivalent (SE) to the Gull Toxoplasma IgG ELISA test, 510(k) No. K9158391, which has been cleared by the FDA and is currently in U.S. commercial distribution. In clinical performance studies, 294 serum…

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

How does its category compare?

All LGD devices

LGD Enzyme Linked Immunoabsorbent Assay, Toxoplasma Gondii: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · LGD

1in 2025

2008: 22009: 12011: 22013: 22015: 12017: 12022: 12024: 22025: 1
2007high 2 (2008) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LGD

Too few LGD 510(k)s in any year since 2007 to give a median.

Recalls per year · LGD

1in 2021

2007: 22008: 12010: 12021: 1
2007high 2 (2007) · low 0 (2009)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LGD

89in 2025

2007: 42008: 142009: 912010: 712011: 1152012: 752013: 352014: 222015: 1212016: 1402017: 1732018: 1002019: 592020: 872021: 382022: 732023: 1182024: 812025: 89
2007high 173 (2017) · low 4 (2007)2025

MAUDE reports naming product code LGD, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—24
20082—114
20091—091
20100—171
20112—0115
20120—075
20132—035
20140—022
20151—0121
20160—0140
20171—0173
20180—0100
20190—059
20200—087
20210—138
20221—073
20230—0118
20242—081
20251—089
20260—0—

What is it indicated for?

The INCSTAR Toxoplasma IgG “fast” ELISA kit contains instructions and materials for the qualitative and/or semi-quantitative detection of IgG antibodies to Toxoplasma gondii in human serum by indirect enzyme-linked immunosorbent assay (ELISA) technique. When performed according to instructions, the Toxoplasma IgG “fast” ELISA test is of value in the determination immunological response to infection with Toxoplasma gondii. The evaluation of paired sera…

Read the full statement (103 words)

The INCSTAR Toxoplasma IgG “fast” ELISA kit contains instructions and materials for the qualitative and/or semi-quantitative detection of IgG antibodies to Toxoplasma gondii in human serum by indirect enzyme-linked immunosorbent assay (ELISA) technique. When performed according to instructions, the Toxoplasma IgG “fast” ELISA test is of value in the determination immunological response to infection with Toxoplasma gondii. The evaluation of paired sera, acute and convalescent, by demonstrating seroconversion or a significant rise in antibody can aid in the diagnosis of primary or reactivated infection with Toxoplasma gondii. This product is not FDA cleared for use in testing (i.e., screening) blood or plasma donors.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K963297: Incstar Toxoplasma Igg Fast Elisa Assay (Cat.#7560).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K963297

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)