510(k) Report

510(k) · Cleared

Cleared

Sharps Container Model# SC001

K963830510(k) TraditionalCleared Feb 10, 1997139-day reviewClass II21 CFR 880.5570

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Image Medical, Inc. · FMI Needle, Hypodermic, Single Lumen

Cleared on Feb 10, 1997 as substantially equivalent to K943575 (Bd Becton Dickinson Vacutainer Systems Preanalytic, 1994) after a 139-day review. Its family tree reaches back 1 generation to 1994.

Decided
Feb 10, 1997
Review
139 days
Class
Class II
Product code
FMI
Recalls
None
Predicates
2

Its longest line of descent runs back 1 generation to K943575 (1994). No later device cites it as a predicate yet.

  1. Root · 1 generation backK943575 B-D Guardian Nestable Sharps CollectorsBd Becton Dickinson Vacutainer Systems Preanalytic · 1994
  2. This deviceK963830 Sharps Container Model# SC001Image Medical, Inc. · 1997
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K943575B-D Guardian Nestable Sharps CollectorsBd Becton Dickinson Vacutainer Systems Preanalytic1994—
0 (this device)K963830Sharps Container Model# SC001Image Medical, Inc.1997—
FIG. 1 — Lineage of K963830, 1994–1997Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FMI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FMI device

  1. #1 K252886 Pen Needlescore 14.5 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary; numbers the summary cites that cannot be its predicate are marked – and kept off the family tree.

TypeNumberDeviceApplicantDecidedRecalls
*K943575B-D Guardian Nestable Sharps Collectors
Summary page 1
…fitting plestic lids end are disposal. Our preduct has & aluminum screw on lid which is tight fiting and prevents lsakage of the contents. 1. B.D. Home Sharps Container K943575 2, Sage Sharps Disposal Systsm NB43860 Tosting: 60681 aluminum has & shear rate of 20000 PS| with a wall thickness of .007 and…
Bd Becton Dickinson Vacutainer Systems Preanalytic1994—
Kept off the family treeK843860FDA’s K843860 is Oxyscreen
Our OCR of the scanned summary read K843860, FDA’s number for Oxyscreen (Erich Jaeger, Inc.). Its FDA name has none of the distinctive words the summary uses for the device it names, “Sage Sharps Disposal System”. Kept off the family tree.
Erich Jaeger, Inc.1984—

Also cleared against K943575: 4 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • 4 other devices also cite its predicate K943575.

How does its category compare?

All FMI devices

FMI Needle, Hypodermic, Single Lumen: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · FMI

11in 2025

2007: 152008: 102009: 72010: 152011: 122012: 172013: 112014: 142015: 102016: 202017: 92018: 202019: 122020: 112021: 182022: 232023: 182024: 32025: 112026 (partial year): 12
2007high 23 (2022) · low 3 (2024)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FMI

141in 2025

2007: 71 days median2008: 85 days median2009: 177 days median2010: 119 days median2011: 113 days median2012: 107 days median2013: 87 days median2014: 155 days median2015: 89 days median2016: 217 days median2017: 253 days median2018: 176 days median2019: 186 days median2020: 263 days median2021: 143 days median2022: 189 days median2023: 112 days median2024: 90 days median2025: 141 days median2026 (partial year): 119 days median
2007high 263 (2020) · low 71 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FMI

1in 2024

2007: 22008: 42009: 32010: 792011: 52012: 12013: 12014: 32015: 12017: 162019: 52020: 32021: 72023: 22024: 12026 (partial year): 1, 1 Class I
2007high 79 (2010) · low 0 (2016)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · FMI

2,424in 2025

2007: 2082008: 1772009: 2632010: 2492011: 2402012: 2152013: 2552014: 2872015: 5672016: 9412017: 1,5472018: 2,3982019: 4,8962020: 4,2452021: 4,5322022: 4,8852023: 4,9862024: 4,0532025: 2,424
2007high 4,986 (2023) · low 177 (2008)2025

MAUDE reports naming product code FMI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200715712208
200810854177
200971773263
20101511979249
2011121135240
2012171071215
201311871255
2014141553287
201510891567
2016202170941
20179253161,547
20182017602,398
20191218654,896
20201126334,245
20211814374,532
20222318904,885
20231811224,986
202439014,053
20251114102,424
2026121191 (1)—

What is it indicated for?

This container is for use by Law Enforcement Agencies. Law Enforcement Officials who frequently encounter syringes and other sharps during searches of suspects, vehicles, property or location.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K963830: Sharps Container Model# SC001.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K963830

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026