510(k) Report

510(k) · Cleared

Cleared

Bme Bone Drill Bits

K964073510(k) TraditionalCleared Nov 14, 199634-day reviewClass I21 CFR 878.4820

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Biomedical Ent., Inc. · GEY Motor, Surgical Instrument, Ac-Powered

Cleared on Nov 14, 1996 after a 34-day review. FDA lists a 510(k) statement for it but has not posted the file, so its predicates are not known. 5 later devices descend from it.

Decided
Nov 14, 1996
Review
34 days
Class
Class I
Product code
GEY
Recalls
None
Predicates
0

5 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 2007: 1 descendant cleared2015: 1 descendant cleared2017: 1 descendant cleared2021: 1 descendant cleared2025: 1 descendant cleared1995200020052010201520202025
  1. This deviceK964073 Bme Bone Drill BitsBiomedical Ent., Inc. · 1996
  2. Descendant · cites it directly · 4 of its ownK071732 MarrowminerStemcor Systems, Inc. · 2007
  3. Descendant · 2 generations on · 3 of its ownK152474 Avitus Bone HarvesterAvitus Orthopaedics, Inc. · 2015 · Recalled
  4. Descendant · 3 generations on · 2 of its ownK170539 Avitus Bone Harvester with Filter Insert - 5mm, Avitus Bone…Avitus Orthopaedics, Inc. · 2017 · Recalled
  5. Descendant · 4 generations on · 1 of its ownK210631 Avitus (r) Bone HarvesterAvitus Orthopaedics, Inc. · 2021
  6. Descendant · 5 generations on · 0 of its ownK243407 Forcyte Autograft Harvest KitForcyte Medical, LLC · 2025

Most influential descendants

Showing 5 of 5 · See all
  • K071732MarrowminerStemcor Systems, Inc. · 2007 · cites it directly4descendants
  • K152474Avitus Bone HarvesterAvitus Orthopaedics, Inc. · 2015 · 2 generations on3descendants
  • K170539Avitus Bone Harvester with Filter Insert - 5mm, Avitus Bone Harvester - 5mm, Avitus Bone…Avitus Orthopaedics, Inc. · 2017 · 3 generations on2descendants
  • K210631Avitus (r) Bone HarvesterAvitus Orthopaedics, Inc. · 2021 · 4 generations on1descendant
  • K243407Forcyte Autograft Harvest KitForcyte Medical, LLC · 2025 · 5 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K964073Bme Bone Drill BitsBiomedical Ent., Inc.1996—
+1K071732MarrowminerStemcor Systems, Inc.2007—
+2K152474Avitus Bone HarvesterAvitus Orthopaedics, Inc.20151
+3K170539Avitus Bone Harvester with Filter Insert - 5mm, Avitus Bone Harvester - 5mm…Avitus Orthopaedics, Inc.20171
+4K210631Avitus (r) Bone HarvesterAvitus Orthopaedics, Inc.2021—
+5K243407Forcyte Autograft Harvest KitForcyte Medical, LLC2025—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200710
201510
201710
202110
202510
FIG. 1 — Lineage of K964073, 1996–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GEY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against?

FDA lists a 510(k) statement for it but has not posted the file, so its predicates are not known.

What descends from it? (5)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K071732MarrowminerStemcor Systems, Inc.20074

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K071732 (Stemcor Systems, Inc., 2007) has gone furthest, with 4 descendants of its own.

How does its category compare?

All GEY devices

GEY Motor, Surgical Instrument, Ac-Powered: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · GEY

FDA has decided no GEY device since 2007.

Median 510(k) review, days · GEY

Too few GEY 510(k)s in any year since 2007 to give a median.

Recalls per year · GEY

2in 2013

2008: 12009: 12012: 12013: 2
2007high 2 (2013) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · GEY

965in 2025

2007: 192008: 92009: 42010: 42011: 112012: 142013: 9012014: 7382015: 2,0132016: 1,9432017: 2,1192018: 1,2882019: 1,1312020: 9522021: 1,1452022: 1,3602023: 1,4442024: 1,4472025: 965
2007high 2,119 (2017) · low 4 (2009)2025

MAUDE reports naming product code GEY, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—019
20080—19
20090—14
20100—04
20110—011
20120—114
20130—2901
20140—0738
20150—02,013
20160—01,943
20170—02,119
20180—01,288
20190—01,131
20200—0952
20210—01,145
20220—01,360
20230—01,444
20240—01,447
20250—0965
20260—0—
Cite this page

510(k) Report. “K964073: Bme Bone Drill Bits.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K964073

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026