510(k) · Cleared
ClearedBridge Long Stem Femoral Component
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Wrightmedicaltechnologyinc · LZO Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented
Cleared on Jan 14, 1997 after an 82-day review. The FDA summary names its predicate without a number.
- Decided
- Jan 14, 1997
- Review
- 82 days
- Class
- Class II
- Product code
- LZO
- Recalls
- None
- Predicates
- 0
The FDA summary names its predicate without a number.
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LZO? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LZO device
- #1 K192827 Quadra-Pscore 19.3 · 10 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | — | BRIDGE™ Hip System Named without a submission number |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All LZO devicesLZO Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · LZO
14in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · LZO
119in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LZO
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · LZO
3,244in 2025
MAUDE reports naming product code LZO, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 9 | 87 | 2 | 138 |
| 2008 | 11 | 63 | 13 | 125 |
| 2009 | 7 | 83 | 42 | 189 |
| 2010 | 15 | 78 | 0 | 394 |
| 2011 | 13 | 87 | 10 | 544 |
| 2012 | 14 | 98 | 14 | 963 |
| 2013 | 26 | 100 | 0 | 1,370 |
| 2014 | 13 | 85 | 1 | 1,477 |
| 2015 | 12 | 115 | 1 | 1,348 |
| 2016 | 10 | 177 | 9 | 1,728 |
| 2017 | 16 | 257 | 5 | 2,165 |
| 2018 | 18 | 163 | 2 | 3,133 |
| 2019 | 28 | 109 | 4 | 3,066 |
| 2020 | 18 | 112 | 3 | 1,963 |
| 2021 | 12 | 170 | 0 | 2,199 |
| 2022 | 11 | 279 | 4 | 1,985 |
| 2023 | 10 | 122 | 2 | 2,066 |
| 2024 | 11 | 111 | 1 | 2,586 |
| 2025 | 14 | 119 | 1 | 3,244 |
| 2026 | 9 | 102 | 0 | — |
What is it indicated for?
The BRIDGE™ Long Stem Femoral Component is indicated for use in total hip arthroplasty for reduction or relief of pain and/or improved hip function in skeletally mature patients with the following conditions: D) non-inflammatory degenerative joint discase such as osteoarthritis, avascular necrosis, ankylosis, protrusio acetabuli, and painful hip dysplasia; 2) inflammatory degenerative joint disease such as rheumatoid arthritis; 3) correction of…
Read the full statement (96 words)
The BRIDGE™ Long Stem Femoral Component is indicated for use in total hip arthroplasty for reduction or relief of pain and/or improved hip function in skeletally mature patients with the following conditions:
D) non-inflammatory degenerative joint discase such as osteoarthritis, avascular necrosis, ankylosis, protrusio acetabuli, and painful hip dysplasia;
2) inflammatory degenerative joint disease such as rheumatoid arthritis;
3) correction of functional deformity;
4) revision procedures where other treatments or devices have failed; and,
5) treatment of nonunion, femoral neck and trochanteric fractures of the proximal femur with head involvement that are unmanageable using other techniques.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K964249 · printed Nov 6, 2026
Cite this page
510(k) Report. “K964249: Bridge Long Stem Femoral Component.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K964249
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026