510(k) Report

510(k) · Cleared

Cleared

Endolumina II Transillumination System 56FR E-5630, 50FR E-5030 and 40FR E-4020, Endolumina II Detachable Tips, 56FR, TA

K964561510(k) TraditionalCleared Feb 11, 199790-day reviewClass I21 CFR 876.4530

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Bioenterics Corp. · FDG Retractor, Fiberoptic

Cleared on Feb 11, 1997 after a 90-day review. The FDA summary names its predicate without a number. 3 later devices descend from it.

Decided
Feb 11, 1997
Review
90 days
Class
Class I
Product code
FDG
Recalls
None
Predicates
0

3 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 1999: 1 descendant cleared2003: 1 descendant cleared2022: 1 descendant cleared1995200020052010201520202025
  1. This deviceK964561 Endolumina II Transillumination System 56FR E-5630, 50FR E-5030 and…Bioenterics Corp. · 1997
  2. Descendant · cites it directly · 2 of its ownK991323 Smith & Nephew Subcutaneous IlluminatorSmith & Nephew, Inc. · 1999
  3. Descendant · 2 generations on · 1 of its ownK032387 Trivex SystemSmith & Nephew, Inc. · 2003 · Recalled
  4. Descendant · 3 generations on · 0 of its ownK212894 PhasTIPPLeMaitre Vascular, Inc. · 2022

Most influential descendants

Showing 3 of 3 · See all
  • K991323Smith & Nephew Subcutaneous IlluminatorSmith & Nephew, Inc. · 1999 · cites it directly2descendants
  • K032387Trivex SystemSmith & Nephew, Inc. · 2003 · 2 generations on1descendant
  • K212894PhasTIPPLeMaitre Vascular, Inc. · 2022 · 3 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K964561Endolumina II Transillumination System 56FR E-5630, 50FR E-5030 and 40FR…Bioenterics Corp.1997—
+1K991323Smith & Nephew Subcutaneous IlluminatorSmith & Nephew, Inc.1999—
+2K032387Trivex SystemSmith & Nephew, Inc.20031
+3K212894PhasTIPPLeMaitre Vascular, Inc.2022—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
199910
200310
202210
FIG. 1 — Lineage of K964561, 1997–2022Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FDG? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—ENDOLUMINA® I Illuminated Bougie
Named without a submission number
—

What descends from it? (3)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K991323Smith & Nephew Subcutaneous IlluminatorSmith & Nephew, Inc.19992

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K991323 (Smith & Nephew, Inc., 1999) has gone furthest, with 2 descendants of its own.

How does its category compare?

All FDG devices

FDG Retractor, Fiberoptic: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · FDG

FDA has decided no FDG device since 2007.

Median 510(k) review, days · FDG

Too few FDG 510(k)s in any year since 2007 to give a median.

Recalls per year · FDG

1in 2009

2008: 12009: 1
2007high 1 (2008) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FDG

2in 2025

2007: 42008: 12009: 12010: 12011: 52012: 82013: 132014: 72015: 52016: 72017: 52018: 32019: 32020: 32022: 42023: 22024: 32025: 2
2007high 13 (2013) · low 0 (2021)2025

MAUDE reports naming product code FDG, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—04
20080—11
20090—11
20100—01
20110—05
20120—08
20130—013
20140—07
20150—05
20160—07
20170—05
20180—03
20190—03
20200—03
20210—00
20220—04
20230—02
20240—03
20250—02
20260—0—

What is it indicated for?

The ENDOLUMINA II Transillumination System (EIB II) is a medical device designed to aid in the identification of the esophagus, rectum, and other structures by transillumination during laparoscopy, thoracoscopy, or open procedures.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K964561: Endolumina II Transillumination System 56FR E-5630, 50FR E-5030 and 40FR E-4020, Endolumina II Detachable Tips, 56FR, TA.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K964561

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026