510(k) Report

510(k) · Cleared

Cleared

Vascutek Gelweave Vascular Graft (Bifurcated Configuration)

K964665510(k) TraditionalCleared Feb 19, 199790-day reviewClass II21 CFR 870.3450

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Carbomedics, Inc. · DSY Prosthesis, Vascular Graft, Of 6mm And Greater Diameter

Cleared on Feb 19, 1997 as substantially equivalent to K952293 (Vascutek, Ltd., 1995) after a 90-day review. Its family tree reaches back 1 generation to 1995. 2 later devices descend from it.

Decided
Feb 19, 1997
Review
90 days
Class
Class II
Product code
DSY
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K952293 (1995). 2 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 2017: 1 descendant cleared2025: 1 descendant clearedReference device: P890045 · Gelseal TM Triaxial Vascular Graft · Carbomedics, Inc. · 1993 · recalledK952293 · Vascutek Gelweave Vascular Graft · Vascutek, Ltd. · 19951995200020052010201520202025
Descendants, by generation 1 generation forward: 1 descendant2 generations forward: 1 descendant K952293 · Vascutek Gelweave Vascular Graft · Vascutek, Ltd. · 19950
  1. Root · 1 generation backK952293 Vascutek Gelweave Vascular GraftVascutek, Ltd. · 1995
  2. This deviceK964665 Vascutek Gelweave Vascular Graft (Bifurcated Configuration)Carbomedics, Inc. · 1997
  3. Descendant · cites it directly · 1 of its ownK162794 Gelweave Vascular GraftsVascutek, Ltd. · 2017
  4. Descendant · 2 generations on · 0 of its ownK241550 Gelweave™ Vascular ProsthesesVascutek, Ltd. · 2025 · Recalled

Most influential descendants

Showing 2 of 2 · See all
  • K162794Gelweave Vascular GraftsVascutek, Ltd. · 2017 · cites it directly1descendant
  • K241550Gelweave™ Vascular ProsthesesVascutek, Ltd. · 2025 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K952293Vascutek Gelweave Vascular GraftVascutek, Ltd.1995—
0 (this device)K964665Vascutek Gelweave Vascular Graft (Bifurcated Configuration)Carbomedics, Inc.1997—
+1K162794Gelweave Vascular GraftsVascutek, Ltd.2017—
+2K241550Gelweave™ Vascular ProsthesesVascutek, Ltd.20251

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201710
202510
FIG. 1 — Lineage of K964665, 1995–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DSY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DSY device

  1. #1 K252445 Fusion Bioline Vascular Graftscore 12.4 · 5 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K952293Vascutek Gelweave Vascular Graft
Summary page 1
…and substantially equivalent in intended use, composition, and function to the straight configuration which received marketing clearance on December 19, 1995 510(k) via K952293. Common name of the device: Prosthesis, Vascular Graft Trade or Proprietary name: Vascutek Gelweave™ vascular graft (bifurcated…
Vascutek, Ltd.1995—
†P890045Gelseal TM Triaxial Vascular GraftCarbomedics, Inc.19932

Also cleared against K952293: 3 other devices →

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K162794Gelweave Vascular GraftsVascutek, Ltd.20171

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • Of its descendants, K162794 (Vascutek, Ltd., 2017) has gone furthest, with 1 descendant of its own.
  • 3 other devices also cite its predicate K952293.

How does its category compare?

All DSY devices

DSY Prosthesis, Vascular Graft, Of 6mm And Greater Diameter: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · DSY

2in 2025

2007: 12008: 12009: 52010: 42011: 12012: 42013: 52014: 22015: 12016: 12017: 32018: 12019: 12020: 12021: 22022: 22023: 22024: 52025: 22026 (partial year): 1
2007high 5 (2009) · low 1 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DSY

160in 2024

2009: 73 days median2010: 55 days median2012: 30 days median2013: 69 days median2017: 269 days median2024: 160 days median
2007high 269 (2017) · low 30 (2012)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DSY

1in 2025

2009: 22010: 52013: 12016: 22025: 12026 (partial year): 1
2007high 5 (2010) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DSY

151in 2025

2007: 1202008: 1642009: 1932010: 1872011: 1652012: 1772013: 2072014: 3522015: 4602016: 2172017: 1932018: 2002019: 2322020: 1692021: 1682022: 1552023: 1492024: 1532025: 151
2007high 460 (2015) · low 120 (2007)2025

MAUDE reports naming product code DSY, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—0120
20081—0164
20095732193
20104555187
20111—0165
20124300177
20135691207
20142—0352
20151—0460
20161—2217
201732690193
20181—0200
20191—0232
20201—0169
20212—0168
20222—0155
20232—0149
202451600153
20252—1151
20261—1—

What is it indicated for?

The Gelweave™ vascular graft (bifurcated configuration) is indicated for repair or replacement of damaged and diseased vessels of the abdomen in cases of aneurysmal or occlusive disease.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K964665: Vascutek Gelweave Vascular Graft (Bifurcated Configuration).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K964665

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026