510(k) · Cleared
ClearedMitraflex Pigmented Wound Dressing
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Polymedica Industries, Inc. · FRO Dressing, Wound, Drug
Cleared on Feb 7, 1997 after a 74-day review. The FDA summary names its predicate without a number.
- Decided
- Feb 7, 1997
- Review
- 74 days
- Class
- Class U
- Product code
- FRO
- Recalls
- None
- Predicates
- 0
The FDA summary names its predicate without a number.
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in FRO? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new FRO device
- #1 K261023 Microdacyn Wound Irrigation Solutionscore 15.5 · 14 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | — | MITRAFLEX Wound Dressings, Wet-Stick Named without a submission number | |
| * | — | MITRAFLEX Wound Dressings Named without a submission number |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All FRO devicesFRO Dressing, Wound, Drug: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · FRO
11in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · FRO
176in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · FRO
2in 2024
Class I (2 since 2007) Class II/III not classified
Adverse event reports per year · FRO
192in 2025
MAUDE reports naming product code FRO, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 29 | 187 | 4 | 55 |
| 2008 | 26 | 130 | 1 | 30 |
| 2009 | 31 | 136 | 1 | 45 |
| 2010 | 31 | 146 | 0 | 122 |
| 2011 | 27 | 177 | 4 | 42 |
| 2012 | 24 | 96 | 0 | 65 |
| 2013 | 19 | 194 | 1 | 139 |
| 2014 | 22 | 214 | 1 | 269 |
| 2015 | 28 | 249 | 2 | 297 |
| 2016 | 28 | 222 | 3 | 147 |
| 2017 | 23 | 147 | 1 | 149 |
| 2018 | 20 | 206 | 0 | 128 |
| 2019 | 16 | 270 | 1 | 136 |
| 2020 | 12 | 226 | 0 | 139 |
| 2021 | 8 | 275 | 6 | 183 |
| 2022 | 9 | 332 | 2 | 176 |
| 2023 | 18 | 283 | 2 (2) | 198 |
| 2024 | 24 | 263 | 2 | 232 |
| 2025 | 11 | 176 | 0 | 192 |
| 2026 | 17 | 254 | 2 | — |
What is it indicated for?
MITRAFLEX Pigmented Wound Dressings are intended for use in the management of:
Venous stasis ulcers
Diabetic ulcers
Pressure sores
Donor sites
Blisters
Skin tears
Incisions
Dermal lesions
Severe sunburn
Minor chemical burns
Poison Ivy
Thermal burns
Dermabrasions and other dermatologic procedurcs
Facelifts and other plastic surgery procedures (e.g. laser resurfacing)
Partial-thickness wounds
Superficial burns
Abrasions and lacerations
Full-thickness wounds
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K964701 · printed Nov 5, 2026
Cite this page
510(k) Report. “K964701: Mitraflex Pigmented Wound Dressing.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K964701
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026