510(k) Report

510(k) · Cleared

Cleared

TZ

K964777510(k) TraditionalCleared Jan 3, 199737-day reviewClass II21 CFR 876.1075

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Gallini Intl., Inc. · KNW Instrument, Biopsy

Cleared on Jan 3, 1997 as substantially equivalent to K951598 (Promedical, Ltd., 1995) after a 37-day review. Its family tree reaches back 1 generation to 1995.

Decided
Jan 3, 1997
Review
37 days
Class
Class II
Product code
KNW
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K951598 (1995). No later device cites it as a predicate yet.

K951598 · Pro-B Biopsy Needle · Promedical, Ltd. · 199519961998
K951598 · Pro-B Biopsy Needle · Promedical, Ltd. · 19950
  1. Root · 1 generation backK951598 Pro-B Biopsy NeedlePromedical, Ltd. · 1995
  2. This deviceK964777 TZGallini Intl., Inc. · 1997
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K951598Pro-B Biopsy NeedlePromedical, Ltd.1995—
0 (this device)K964777TZGallini Intl., Inc.1997—
FIG. 1 — Lineage of K964777, 1995–1997Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KNW? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KNW device

  1. #1 K260572 Marrow Marxmanscore 14.5 · 10 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K951598Pro-B Biopsy Needle
Summary page 1
…L. Hawthorne U.S. Representative SUBMISSION DATE: November 22, 1996 DEVICE NAME: “TZ®" Biopsy Needle PREDICATE DEVICE: ProMedical Lid. - PRO-B Biopsy Needie 510(K)# - K951598 DESCRIPTION OF The device is a spring loaded, disposable biopsy DEVICE FUNCTION: needle. INTENDED USE: This device is intended…
Promedical, Ltd.1995—

Also cleared against K951598: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • 2 other devices also cite its predicate K951598.

How does its category compare?

All KNW devices

KNW Instrument, Biopsy: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · KNW

12in 2025

2007: 62008: 42009: 62010: 32011: 102012: 72013: 32014: 82015: 102016: 92017: 82018: 72019: 52020: 82021: 92022: 82023: 72024: 52025: 122026 (partial year): 7
2007high 12 (2025) · low 3 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KNW

178in 2025

2007: 94 days median2008: 53 days median2009: 35 days median2010: 57 days median2011: 64 days median2012: 94 days median2013: 100 days median2014: 95 days median2015: 106 days median2016: 127 days median2017: 90 days median2018: 71 days median2019: 94 days median2020: 92 days median2021: 54 days median2022: 203 days median2023: 164 days median2024: 114 days median2025: 178 days median2026 (partial year): 29 days median
2007high 203 (2022) · low 35 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KNW

1in 2024

2007: 12008: 72009: 32010: 22011: 52012: 12013: 1, 1 Class I2014: 32016: 52017: 12019: 42021: 32022: 32023: 22024: 12026 (partial year): 4, 3 Class I
2007high 7 (2008) · low 0 (2015)2026

Class I (4 since 2007) Class II/III not classified

Adverse event reports per year · KNW

1,667in 2025

2007: 7662008: 3632009: 3512010: 1622011: 672012: 932013: 982014: 1932015: 5912016: 2972017: 7602018: 1,0122019: 4,1952020: 5,1202021: 1,0202022: 5352023: 9312024: 1,2832025: 1,667
2007high 5,120 (2020) · low 67 (2011)2025

MAUDE reports naming product code KNW, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20076941766
20084537363
20096353351
20103572162
20111064567
2012794193
201331001 (1)98
20148953193
2015101060591
201691275297
20178901760
201877101,012
201959444,195
202089205,120
202195431,020
202282033535
202371642931
2024511411,283
20251217801,667
20267294 (3)—

What is it indicated for?

This device is intended to be used to take high quality histological core samples from soft tissue, including (but not limited to) liver, kidney, prostate.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K964777: TZ.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K964777

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026