510(k) · Cleared
ClearedFuji Computed Radiography FCR/Dicom Gateway Unit CR-DM666
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Fujifilm Medical System U.S.A., Inc. · LMD System, Digital Image Communications, Radiological
Cleared on Mar 21, 1997 as substantially equivalent to K960326 (Fujifilm Medical System U.S.A., Inc., 1996) after a 56-day review. Its family tree reaches back 2 generations to 1993.
- Decided
- Mar 21, 1997
- Review
- 56 days
- Class
- Class I
- Product code
- LMD
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 2 generations to K921112 (1993). No later device cites it as a predicate yet.
- Root · 2 generations backK921112 Fuji Computed Radiography OD-F623 Optical-DiskFujifilm Medical System U.S.A., Inc. · 1993
- 1 generation backK960326 FCR DMS Optical Disk Image Filing Unit OD-F614, ODF614L &…Fujifilm Medical System U.S.A., Inc. · 1996
- This deviceK970293 Fuji Computed Radiography FCR/Dicom Gateway Unit CR-DM666Fujifilm Medical System U.S.A., Inc. · 1997
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −2 | K921112 | Fuji Computed Radiography OD-F623 Optical-Disk | Fujifilm Medical System U.S.A., Inc. | 1993 | — |
| −1 | K960326 | FCR DMS Optical Disk Image Filing Unit OD-F614, ODF614L & Multimodality System | Fujifilm Medical System U.S.A., Inc. | 1996 | — |
| 0 (this device) | K970293 | Fuji Computed Radiography FCR/Dicom Gateway Unit CR-DM666 | Fujifilm Medical System U.S.A., Inc. | 1997 | — |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LMD? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K960326 | FCR DMS Optical Disk Image Filing Unit OD-F614, ODF614L & Multimodality SystemSummary page 1…4/L Series. FDA assigned the predicate to regulatory class II citing 21 CFR § 892.1750. FDA’s accession number for the premarket notification for the predicate device is K960326. FDA cleared the marketing of the predicate device in a letter dated March 7, 1996. Description of the Device [21 CFR 807.92(a)(… | 1996 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 4 years and passes through 1 company; a new generation was cleared every 2.9 years on median.
- None of the 2 ancestors has a recall.
- 1 other device also cites its predicate K960326.
How does its category compare?
All LMD devicesLMD System, Digital Image Communications, Radiological: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · LMD
FDA has decided no LMD device since 2007.
Median 510(k) review, days · LMD
Too few LMD 510(k)s in any year since 2007 to give a median.
Recalls per year · LMD
2in 2020
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · LMD
16in 2025
MAUDE reports naming product code LMD, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 2 | 1 |
| 2008 | 0 | — | 1 | 2 |
| 2009 | 0 | — | 1 | 3 |
| 2010 | 0 | — | 0 | 9 |
| 2011 | 0 | — | 0 | 1 |
| 2012 | 0 | — | 1 | 2 |
| 2013 | 0 | — | 0 | 4 |
| 2014 | 0 | — | 0 | 12 |
| 2015 | 0 | — | 1 | 9 |
| 2016 | 0 | — | 0 | 3 |
| 2017 | 0 | — | 0 | 2 |
| 2018 | 0 | — | 0 | 4 |
| 2019 | 0 | — | 0 | 2 |
| 2020 | 0 | — | 2 | 2 |
| 2021 | 0 | — | 0 | 2 |
| 2022 | 0 | — | 0 | 6 |
| 2023 | 0 | — | 0 | 7 |
| 2024 | 0 | — | 0 | 8 |
| 2025 | 0 | — | 0 | 16 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
The indications for use of the FCR/DICOM Gateway Unit CR-DM666 is to serve as a gateway between a proprietary FCR DMS network and a standard ACR/NEMA Digital Imaging and Communications (DICOM) network.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K970293 · printed Nov 6, 2026
Cite this page
510(k) Report. “K970293: Fuji Computed Radiography FCR/Dicom Gateway Unit CR-DM666.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K970293
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026