510(k) Report

510(k) · Cleared

Cleared

Tritest Reagent CD3 Fitc/CD8 PE/CD45 Percp;with Trucount Absolute Count Tubes

K970326510(k) TraditionalCleared Nov 21, 1997297-day reviewClass II21 CFR 864.5220

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Becton Dickinson Immunocytometry Systems · GKZ Counter, Differential Cell

Cleared on Nov 21, 1997 as substantially equivalent to K913192 (Bd Becton Dickinson Vacutainer Systems Preanalytic, 1992) and 1 other predicate after a 297-day review. Its family tree reaches back 1 generation to 1992. 11 later devices descend from it.

Decided
Nov 21, 1997
Review
297 days
Class
Class II
Product code
GKZ
Recalls
None
Predicates
2

Its longest line of descent runs back 1 generation to K913192 (1992). 2 ancestors in all. 11 later devices descend from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1994: 1 other ancestor1998: 2 descendants cleared2002: 1 descendant cleared2017: 1 descendant cleared2006: 3 descendants cleared2015: 1 descendant cleared2010: 1 descendant cleared2020: 1 descendant cleared2009: 1 descendant clearedK913192 · Simultest (TM) Imk-Lymphocyte · Bd Becton Dickinson Vacutainer Systems Preanalytic · 19921990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor 1 generation forward: 1 descendant2 generations forward: 7 descendants3 generations forward: 2 descendants4 generations forward: 1 descendant K913192 · Simultest (TM) Imk-Lymphocyte · Bd Becton Dickinson Vacutainer Systems Preanalytic · 19920
  1. Root · 1 generation backK913192 Simultest (TM) Imk-LymphocyteBd Becton Dickinson Vacutainer Systems Preanalytic · 1992
  2. This deviceK970326 Tritest Reagent CD3 Fitc/CD8 PE/CD45 Percp;with Trucount Absolute…Becton Dickinson Immunocytometry Systems · 1997
  3. Descendant · cites it directly · 10 of its ownK974360 Multitest CD3/CD8/CD45/CD4Becton Dickinson Immunocytometry Systems · 1998
  4. Descendant · 2 generations on · 5 of its ownK980858 Multitest CD3/CD16+56/CD45/CD19 Reagent and Multitest Imk Kit Lysing…Becton Dickinson Immunocytometry Systems · 1998 · Recalled
  5. Descendant · 3 generations on · 3 of its ownK060375 BD Multitest 6-Color TBNK Reagent with BD Trucount Tubes with Models…Bd Biosciences · 2006
  6. Descendant · 4 generations on · 2 of its ownK090967 BD Multitest 6-Color TBNK Reagent, Model 644611Bd Biosciences · 2009 · Recalled
  7. Descendant · 2 generations on · 1 of its ownK170974 BD FACSLyric Flow Cytometer (3-1, 4-2, 4-2-2 and 4-3-3 optical…Becton, Dickinson and Company · 2017 · Recalled

Showing 5 of 11 descendants. See all descendants

Descendants cleared per year

1998: 22002: 12006: 32009: 12010: 12015: 12017: 12020: 1
1998high 3 (2006) · low 0 (1999)2026

Most influential descendants

Showing 5 of 11 · See all
  • K974360Multitest CD3/CD8/CD45/CD4Becton Dickinson Immunocytometry Systems · 1998 · cites it directly10descendants
  • K980858Multitest CD3/CD16+56/CD45/CD19 Reagent and Multitest Imk Kit Lysing SolutionBecton Dickinson Immunocytometry Systems · 1998 · 2 generations on5descendants
  • K060375BD Multitest 6-Color TBNK Reagent with BD Trucount Tubes with Models 337 and 166Bd Biosciences · 2006 · 3 generations on3descendants
  • K090967BD Multitest 6-Color TBNK Reagent, Model 644611Bd Biosciences · 2009 · 4 generations on2descendants
  • K170974BD FACSLyric Flow Cytometer (3-1, 4-2, 4-2-2 and 4-3-3 optical configurations), BD…Becton, Dickinson and Company · 2017 · 2 generations on1descendant
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K913192Simultest (TM) Imk-LymphocyteBd Becton Dickinson Vacutainer Systems Preanalytic1992—
0 (this device)K970326Tritest Reagent CD3 Fitc/CD8 PE/CD45 Percp;with Trucount Absolute Count TubesBecton Dickinson Immunocytometry Systems1997—
+1K974360Multitest CD3/CD8/CD45/CD4Becton Dickinson Immunocytometry Systems1998—
+2K980858Multitest CD3/CD16+56/CD45/CD19 Reagent and Multitest Imk Kit Lysing SolutionBecton Dickinson Immunocytometry Systems19981
+3K060375BD Multitest 6-Color TBNK Reagent with BD Trucount Tubes with Models 337 and 166Bd Biosciences2006—
+4K090967BD Multitest 6-Color TBNK Reagent, Model 644611Bd Biosciences20093
+2K170974BD FACSLyric Flow Cytometer (3-1, 4-2, 4-2-2 and 4-3-3 optical…Becton, Dickinson and Company201717

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199410

Descendants by year cleared

Year clearedDevicesWith a Class I recall
199820
200210
200630
200910
201010
201510
201710
202010
FIG. 1 — Lineage of K970326, 1992–2020Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GKZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GKZ device

  1. #1 K250943 Sysmex XR-Series (XR-10) Automated Hematology…score 13.2 · 3 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K913192Simultest (TM) Imk-Lymphocyte
Summary page 1
…/CD8 PE/CD45 PerCPreagent, when used to enumerate percentages of lymphogrtes is substantially equivalent to IMK-Lymphocyte Tube E that was cleared to marker under 510(k) K913192. When the TriTEST reagent is used with TRUCOUNT Absolute Count Tubes, it is substantially equivalent to the BDIS FACSCount system…
Bd Becton Dickinson Vacutainer Systems Preanalytic1992—
*K933486Fascount Systme
Summary page 1
…der 510(k) K913192. When the TriTEST reagent is used with TRUCOUNT Absolute Count Tubes, it is substantially equivalent to the BDIS FACSCount system cleared under 510(k) K933486. Description of the Device (21 CFR 807.92(2)(4)) The BDIS TrTEST CD3 flucrescein isothiocyanate (FITC)/CD8 phycoerythrin (PE)/CD…
Becton Dickinson Immunocytometry Systems19941

Also cleared against K913192: 4 other devices →

What descends from it? (11)

See all 11

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K974360Multitest CD3/CD8/CD45/CD4Becton Dickinson Immunocytometry Systems199810

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • 1 of the 2 ancestors has a recall of any class.
  • Of its descendants, K974360 (Becton Dickinson Immunocytometry Systems, 1998) has gone furthest, with 10 descendants of its own.
  • 4 other devices also cite its predicate K913192.

How does its category compare?

All GKZ devices

GKZ Counter, Differential Cell: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · GKZ

4in 2025

2007: 62008: 62009: 62010: 42011: 32012: 32013: 12014: 32015: 32016: 32017: 42018: 32019: 52020: 12022: 32023: 42024: 32025: 42026 (partial year): 4
2007high 6 (2007) · low 0 (2021)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GKZ

108in 2025

2007: 117 days median2008: 99 days median2009: 147 days median2010: 290 days median2011: 315 days median2012: 408 days median2014: 165 days median2015: 273 days median2016: 198 days median2017: 280 days median2018: 270 days median2019: 210 days median2022: 638 days median2023: 329 days median2024: 157 days median2025: 108 days median2026 (partial year): 254 days median
2007high 638 (2022) · low 99 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GKZ

1in 2025

2007: 372008: 52009: 132010: 272011: 282012: 72013: 62015: 32016: 32017: 32018: 2, 2 Class I2019: 22020: 12022: 42023: 12025: 1
2007high 37 (2007) · low 0 (2014)2026

Class I (2 since 2007) Class II/III not classified

Adverse event reports per year · GKZ

77in 2025

2007: 2682008: 9252009: 5592010: 8962011: 2,9052012: 2,9592013: 3,0702014: 3,1122015: 1,9722016: 3,3382017: 2292018: 4972019: 9082020: 3422021: 3912022: 1982023: 1552024: 1152025: 77
2007high 3,338 (2016) · low 77 (2025)2025

MAUDE reports naming product code GKZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007611737268
20086995925
2009614713559
2010429027896
20113315282,905
2012340872,959
20131—63,070
2014316503,112
2015327331,972
2016319833,338
201742803229
201832702 (2)497
201952102908
20201—1342
20210—0391
202236384198
202343291155
202431570115
20254108177
202642540—

What is it indicated for?

For use with any flow cytometer equipped with a 488 nm laser and capable of detection in the ranges: 515-545 nm, 562-607 nm, and > 650 nm

For use with erythrocyte lysed whole blood

For use with or without an isotype control

To characterize and monitor forms of autoimmune diseases, such as lupus

To characterize and monitor congenital or acquired immunodeficiencies, such as SCID or AIDS

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K970326: Tritest Reagent CD3 Fitc/CD8 PE/CD45 Percp;with Trucount Absolute Count Tubes.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K970326

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026