510(k) · Cleared
Recalled · Class II · 2013MMB Calibrator
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Dade Chemistry Systems, Inc. · JIT Calibrator, Secondary
Cleared on Mar 3, 1997 after a 33-day review. The FDA summary names its predicate without a number. 6 later devices descend from it. It has been recalled once.
- Decided
- Mar 3, 1997
- Review
- 33 days
- Class
- Class II
- Product code
- JIT
- Recalls
- 1
- Predicates
- 0
6 later devices descend from it, 1 citing it directly.
- This deviceK970336 MMB CalibratorDade Chemistry Systems, Inc. · 1997
- Descendant · cites it directly · 5 of its ownK051087 Dimension Vista Integrated SystemDade Behring, Inc. · 2005 · Recalled
- Descendant · 2 generations on · 1 of its ownK073561 Dimension Vista System Immunoglobulin G Flex Reagent Cartridge…Dade Behring, Inc. · 2008
- Descendant · 2 generations on · 1 of its ownK061838 Dimension Vista Chemistry 1 Calibrator, Model KC110Dade Behring, Inc. · 2006 · Recalled
- Descendant · 2 generations on · 0 of its ownK143720 Dimension Vista MMB AssaySiemens Healthcare Diagnostics · 2015 · Recalled
- Descendant · 3 generations on · 0 of its ownK140790 Dimension Vista Chemistry 1 Calibrator (CHEM 1 CAL), Dimension Vista…Siemens Healthcare Diagnostics · 2015 · Recalled
Showing 5 of 6 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 6 · See all- K051087Dimension Vista Integrated SystemDade Behring, Inc. · 2005 · cites it directly5descendants
- K073561Dimension Vista System Immunoglobulin G Flex Reagent Cartridge, Dimension Vista System…Dade Behring, Inc. · 2008 · 2 generations on1descendant
- K061838Dimension Vista Chemistry 1 Calibrator, Model KC110Dade Behring, Inc. · 2006 · 2 generations on1descendant
- K143720Dimension Vista MMB AssaySiemens Healthcare Diagnostics · 2015 · 2 generations on0descendants
- K140790Dimension Vista Chemistry 1 Calibrator (CHEM 1 CAL), Dimension Vista Magnesium Flex…Siemens Healthcare Diagnostics · 2015 · 3 generations on0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K970336 | MMB Calibrator | Dade Chemistry Systems, Inc. | 1997 | — |
| +1 | K051087 | Dimension Vista Integrated System | Dade Behring, Inc. | 2005 | 32 |
| +2 | K073561 | Dimension Vista System Immunoglobulin G Flex Reagent Cartridge, Dimension… | Dade Behring, Inc. | 2008 | — |
| +2 | K061838 | Dimension Vista Chemistry 1 Calibrator, Model KC110 | Dade Behring, Inc. | 2006 | 3 |
| +2 | K143720 | Dimension Vista MMB Assay | Siemens Healthcare Diagnostics | 2015 | 5 |
| +3 | K140790 | Dimension Vista Chemistry 1 Calibrator (CHEM 1 CAL), Dimension Vista Magnesium… | Siemens Healthcare Diagnostics | 2015 | 2 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2005 | 1 | 0 |
| 2006 | 1 | 0 |
| 2008 | 2 | 0 |
| 2015 | 2 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JIT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | — | Abbott Laboratories IMx® Stat CK-MB Calibrator Named without a submission number |
What descends from it? (6)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K051087 | Dimension Vista Integrated System | 2005 | 5 |
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Jun 5, 2013 | Class II | Z-1925-2013 | Material/Component Contamination | Siemens Healthcare Diagnostics has received complaints that the lyophilized cake is not fully dissolved after the stated time in the MMB calibrator Instructions For Use (IFU). The frequency of this occurrence is low but if it occurs… |
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K051087 (Dade Behring, Inc., 2005) has gone furthest, with 5 descendants of its own.
How does its category compare?
All JIT devicesJIT Calibrator, Secondary: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · JIT
7in 2017
2026 to Oct 25, outlined.
Median 510(k) review, days · JIT
28in 2017
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · JIT
1in 2023
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · JIT
7in 2025
MAUDE reports naming product code JIT, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 5 | 78 | 1 | 0 |
| 2008 | 6 | 46 | 0 | 0 |
| 2009 | 2 | — | 2 | 0 |
| 2010 | 6 | 65 | 0 | 3 |
| 2011 | 7 | 48 | 3 | 2 |
| 2012 | 2 | — | 3 | 10 |
| 2013 | 5 | 140 | 0 | 43 |
| 2014 | 10 | 33 | 2 | 9 |
| 2015 | 4 | 30 | 1 | 6 |
| 2016 | 4 | 33 | 0 | 3 |
| 2017 | 7 | 28 | 0 | 7 |
| 2018 | 0 | — | 5 | 8 |
| 2019 | 0 | — | 0 | 215 |
| 2020 | 0 | — | 2 | 12 |
| 2021 | 0 | — | 0 | 3 |
| 2022 | 0 | — | 0 | 4 |
| 2023 | 0 | — | 1 | 6 |
| 2024 | 0 | — | 0 | 17 |
| 2025 | 0 | — | 0 | 7 |
| 2026 | 0 | — | 1 | — |
What is it indicated for?
The MMB Calibrator is intended to be used to calibrate the MMB method for the Dimension® RxL clinical chemistry system with the heterogeneous immunoassay module.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K970336 · printed Nov 4, 2026
Cite this page
510(k) Report. “K970336: MMB Calibrator.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K970336
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026