510(k) Report

510(k) · Cleared

Cleared

Opti-Plast XL 5.5 F Pta Catheter

K970725510(k) TraditionalCleared May 9, 199770-day reviewClass II21 CFR 870.1250

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Vas-Cath, Inc. · LIT Catheter, Angioplasty, Peripheral, Transluminal

Cleared on May 9, 1997 as substantially equivalent to K933483 (Vas-Cath, Inc., 1993) and 1 other predicate after a 70-day review. Its family tree reaches back 1 generation to 1993.

Decided
May 9, 1997
Review
70 days
Class
Class II
Product code
LIT
Recalls
None
Predicates
2

Its longest line of descent runs back 1 generation to K933483 (1993). 2 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 1995: 1 other ancestorK933483 · Opti-Plast 5F Pta Catheters · Vas-Cath, Inc. · 199319901992199419961998
Other ancestors, by generation 1 generation back: 1 other ancestor K933483 · Opti-Plast 5F Pta Catheters · Vas-Cath, Inc. · 19930
  1. Root · 1 generation backK933483 Opti-Plast 5F Pta CathetersVas-Cath, Inc. · 1993
  2. This deviceK970725 Opti-Plast XL 5.5 F Pta CatheterVas-Cath, Inc. · 1997
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K933483Opti-Plast 5F Pta CathetersVas-Cath, Inc.1993—
0 (this device)K970725Opti-Plast XL 5.5 F Pta CatheterVas-Cath, Inc.1997—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199510
FIG. 1 — Lineage of K970725, 1993–1997Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LIT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LIT device

  1. #1 K241040 Amethyst HP PTA OTW 0.035 Catheterscore 13.9 · 9 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K933483Opti-Plast 5F Pta Catheters
Summary page 1
…Catheter XL (Xtra-Large) Common/Usual Name: Peripheral Angioplasty Catheter Classification Name: Surgical Vessel Dilator C. Predicate Device : Opti-Plast® PTA Catheter (K933483) Trade Name: Opti-Plast Predicate Device for the Indications for Use: Medi-tech® XXL™ Balloon Dilatation Catheter (K952063) D.- D…
Vas-Cath, Inc.1993—
*K952063XXL Ballon Dilatation Catheter
Summary page 1
…. Predicate Device : Opti-Plast® PTA Catheter (K933483) Trade Name: Opti-Plast Predicate Device for the Indications for Use: Medi-tech® XXL™ Balloon Dilatation Catheter (K952063) D.- Device Description: The Vas-Cath Opti-Plast® XL 5.5 F PTA Catheter is a dual lumen catheter with a balloon mounted on its d…
Boston Scientific Corp1995—

Also cleared against K933483: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • None of the 2 ancestors has a recall.
  • 1 other device also cites its predicate K933483.

How does its category compare?

All LIT devices

LIT Catheter, Angioplasty, Peripheral, Transluminal: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · LIT

3in 2025

2007: 62008: 82009: 72010: 132011: 102012: 192013: 142014: 122015: 192016: 112017: 92018: 62019: 42020: 92021: 42022: 82023: 62024: 62025: 32026 (partial year): 4
2007high 19 (2012) · low 3 (2025)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LIT

90in 2025

2007: 64 days median2008: 53 days median2009: 29 days median2010: 78 days median2011: 82 days median2012: 29 days median2013: 79 days median2014: 90 days median2015: 112 days median2016: 116 days median2017: 57 days median2018: 118 days median2019: 40 days median2020: 125 days median2021: 61 days median2022: 122 days median2023: 167 days median2024: 43 days median2025: 90 days median2026 (partial year): 205 days median
2007high 205 (2026) · low 29 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LIT

1in 2025

2009: 22010: 12013: 2, 2 Class I2014: 32016: 12018: 22019: 32021: 12024: 22025: 1
2007high 3 (2014) · low 0 (2007)2026

Class I (2 since 2007) Class II/III not classified

Adverse event reports per year · LIT

2,073in 2025

2007: 5772008: 5132009: 6232010: 8092011: 8572012: 1,2772013: 1,2422014: 1,1782015: 1,2792016: 1,5292017: 2,0812018: 2,1882019: 2,4052020: 2,4432021: 2,4922022: 2,1552023: 1,8072024: 1,9132025: 2,073
2007high 2,492 (2021) · low 513 (2008)2025

MAUDE reports naming product code LIT, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20076640577
20088530513
20097292623
201013781809
201110820857
2012192901,277
201314792 (2)1,242
2014129031,178
20151911201,279
20161111611,529
201795702,081
2018611822,188
201944032,405
2020912502,443
202146112,492
2022812202,155
2023616701,807
202464321,913
202539012,073
202642050—

What is it indicated for?

The Opti-Plast® XL 5.5 F PTA Catheter is reccommended for use in the Percutaneous Transluminal Angioplasty of the Iliac and Femoral vessels. This catheter is not for use in coronary arteries. The device is indicated for single use only and indicated not to be resterilized nor reused.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K970725: Opti-Plast XL 5.5 F Pta Catheter.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K970725

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026