510(k) · Cleared
ClearedLifecore O-Ring Abutment;Lifecore Dalla Bona Abutment
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Lifecore Biomedical, Inc. · DZE Implant, Endosseous, Root-Form
Cleared on May 27, 1997 as substantially equivalent to K921764 (Implant Support Systems, Inc., 1992) and 1 other predicate after an 84-day review. Its family tree reaches back 1 generation to 1992.
- Decided
- May 27, 1997
- Review
- 84 days
- Class
- Class II
- Product code
- DZE
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 1 generation to K921764 (1992). 2 ancestors in all. No later device cites it as a predicate yet.
- Root · 1 generation backK921764 Dalla Bona Ball & Sockey Attach. Snap Type PrecisImplant Support Systems, Inc. · 1992
- This deviceK970776 Lifecore O-Ring Abutment;Lifecore Dalla Bona AbutmentLifecore Biomedical, Inc. · 1997
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K921764 | Dalla Bona Ball & Sockey Attach. Snap Type Precis | Implant Support Systems, Inc. | 1992 | — |
| 0 (this device) | K970776 | Lifecore O-Ring Abutment;Lifecore Dalla Bona Abutment | Lifecore Biomedical, Inc. | 1997 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1993 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DZE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DZE device
- #1 K211090 ZENEX Implant Systemscore 25.4 · 15 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K921764 | Dalla Bona Ball & Sockey Attach. Snap Type PrecisSummary page 1…r 21 CFR 872.3165). 3. ’équivalent Device: The device is substantially equivalent to the commercially marketed products known as Lifecore Overdenture Abutments Systems (K921764, K924190). 4. Device Description: The abutment is designed for use with an endosseous implant which is implanted in the lower or… | 1992 |
| * | K924190 | Iss O-Ring AttachmentSummary page 1…872.3165). 3. ’équivalent Device: The device is substantially equivalent to the commercially marketed products known as Lifecore Overdenture Abutments Systems (K921764, K924190). 4. Device Description: The abutment is designed for use with an endosseous implant which is implanted in the lower or upper ja… | 1993 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- None of the 2 ancestors has a recall.
How does its category compare?
All DZE devicesDZE Implant, Endosseous, Root-Form: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · DZE
31in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DZE
184in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DZE
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · DZE
465,788in 2025
MAUDE reports naming product code DZE, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 43 | 107 | 11 | 225 |
| 2008 | 61 | 118 | 4 | 393 |
| 2009 | 41 | 110 | 3 | 164 |
| 2010 | 34 | 162 | 3 | 360 |
| 2011 | 26 | 194 | 0 | 362 |
| 2012 | 39 | 174 | 11 | 358 |
| 2013 | 42 | 195 | 1 | 391 |
| 2014 | 36 | 265 | 7 | 1,124 |
| 2015 | 36 | 215 | 3 | 2,894 |
| 2016 | 40 | 219 | 15 | 1,116 |
| 2017 | 48 | 223 | 4 | 9,719 |
| 2018 | 41 | 200 | 4 | 12,892 |
| 2019 | 31 | 231 | 8 | 167,016 |
| 2020 | 41 | 230 | 0 | 255,524 |
| 2021 | 34 | 182 | 6 | 479,618 |
| 2022 | 34 | 243 | 0 | 483,224 |
| 2023 | 35 | 248 | 0 | 537,585 |
| 2024 | 40 | 222 | 1 | 473,629 |
| 2025 | 31 | 184 | 1 | 465,788 |
| 2026 | 15 | 194 | 2 | — |
What is it indicated for?
The Lifecore Sustain and Restore Dental Implant Systems are intended for use in either partially or fully edentulous mandibles or maxillae in the following areas:
Support of fixed (cemented) restorations utilizing multiple abutments;
Support of fixed detachable (screw retained) prosthetics utilizing multiple abutments;
Overdenture retention by means of a ball overdenture attachment, o-ring attachment, dalla bona or hader bar;
Terminal or intermediate abutment support for fixed bridgework;
Free standing restorations without involvement of adjacent dentition.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K970776 · printed Nov 6, 2026
Cite this page
510(k) Report. “K970776: Lifecore O-Ring Abutment;Lifecore Dalla Bona Abutment.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K970776
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026