Sims Hyperinflation Bag System

K970785510(k) TraditionalCleared Jun 13, 1997101-day reviewClass II21 CFR 868.5905

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Sims · NHK Resuscitator, Manual, Non Self-Inflating

Cleared on Jun 13, 1997 after a 101-day review. FDA’s file for it is a 510(k) statement, which names no predicate. 2 later devices descend from it.

Decided
Jun 13, 1997
Review
101 days
Class
Class II
Product code
NHK
Recalls
None
Predicates
0

2 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 2009: 1 descendant cleared2010: 1 descendant cleared1995200020052010201520202025
  1. This deviceK970785 Sims Hyperinflation Bag SystemSims · 1997
  2. Descendant · cites it directly · 1 of its ownK092687 Venti.Plus Hyperinflation Bag System with Pressure ManometerA Plus Medical · 2009
  3. Descendant · 2 generations on · 0 of its ownK102377 Ventiplus Disposable Manometer 0-60 CM H2O; Ventiplus Disposable…A Plus Medical · 2010

Most influential descendants

Showing 2 of 2 · See all
  • K092687Venti.Plus Hyperinflation Bag System with Pressure ManometerA Plus Medical · 2009 · cites it directly1descendant
  • K102377Ventiplus Disposable Manometer 0-60 CM H2O; Ventiplus Disposable Manometer 0-20 CM H2O…A Plus Medical · 2010 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K970785Sims Hyperinflation Bag SystemSims1997—
+1K092687Venti.Plus Hyperinflation Bag System with Pressure ManometerA Plus Medical2009—
+2K102377Ventiplus Disposable Manometer 0-60 CM H2O; Ventiplus Disposable Manometer…A Plus Medical2010—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200910
201010
FIG. 1 — Lineage of K970785, 1997–2010Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in NHK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K092687Venti.Plus Hyperinflation Bag System with Pressure ManometerA Plus Medical20091

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K092687 (A Plus Medical, 2009) has gone furthest, with 1 descendant of its own.

How does its category compare?

All NHK devices

NHK Resuscitator, Manual, Non Self-Inflating: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · NHK

1in 2009

2009: 1
2007high 1 (2009) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · NHK

Too few NHK 510(k)s in any year since 2007 to give a median.

Recalls per year · NHK

No recall names NHK since 2007.

Adverse event reports per year · NHK

2in 2025

2008: 22009: 12010: 22011: 22012: 32013: 42014: 152015: 322016: 72017: 52018: 32019: 62020: 12021: 72022: 72023: 82024: 62025: 2
2007high 32 (2015) · low 0 (2007)2025

MAUDE reports naming product code NHK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—02
20091—01
20100—02
20110—02
20120—03
20130—04
20140—015
20150—032
20160—07
20170—05
20180—03
20190—06
20200—01
20210—07
20220—07
20230—08
20240—06
20250—02
20260—0—

What is it indicated for?

The SIMS Hyperinflation Bag System is a pulmonary-assist device intended to hyper-ventilate a patient by forcing a volume of fresh gas into the patient via compression of the ventilator bag to prevent atelectasis. It is designed for patients suffeging from respiratory insufficiency. Typical treatment consists of hyperinflating the patient’s lung over several respiration cycles, each terminating in a preset PEEP (positive end expiratory pressure). Peak…

Read the full statement (166 words)

The SIMS Hyperinflation Bag System is a pulmonary-assist device intended to hyper-ventilate a patient by forcing a volume of fresh gas into the patient via compression of the ventilator bag to prevent atelectasis. It is designed for patients suffeging from respiratory insufficiency. Typical treatment consists of hyperinflating the patient’s lung over several respiration cycles, each terminating in a preset PEEP (positive end expiratory pressure). Peak pressure is controlled by the user and monitored by means of a user-supplied manometer or optional disposable manometer.

The SIMS Hyperinflation Bag System is a pulmonary-assist device intended to hyper-ventilate a patient by forcing a volume of fresh gas into the patient via compression of the ventilator bag to prevent atelectasis. It is designed for patients suffeging from respiratory insufficiency. Typical treatment consists of hyperinflating the patient’s lung over several respiration cycles, each terminating in a preset PEEP (positive end expiratory pressure). Peak pressure is controlled by the user and monitored by means of a user-supplied manometer or optional disposable manometer.

Indications for use read by OCR from a scanned FDA 510(k) statement, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K970785: Sims Hyperinflation Bag System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K970785

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026