510(k) Report

510(k) · Cleared

Cleared

Endosoft Soft Tip Needle (20 GA. and 19 GA.)

K970873510(k) TraditionalCleared May 20, 199771-day reviewClass I21 CFR 886.4350

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

American Medical Devices, Inc. · HMX Cannula, Ophthalmic

Cleared on May 20, 1997 after a 71-day review. The FDA summary names its predicate without a number.

Decided
May 20, 1997
Review
71 days
Class
Class I
Product code
HMX
Recalls
None
Predicates
0

The FDA summary names its predicate without a number.

FIG. 1 — Lineage of K970873Source: FDA 510(k) database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HMX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—Visitec
Named without a submission number
—
*—Grieshaber
Named without a submission number
—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

How does its category compare?

All HMX devices

HMX Cannula, Ophthalmic: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · HMX

FDA has decided no HMX device since 2007.

Median 510(k) review, days · HMX

Too few HMX 510(k)s in any year since 2007 to give a median.

Recalls per year · HMX

1in 2025

2007: 12008: 12010: 62012: 1, 1 Class I2013: 12018: 22019: 62025: 1
2007high 6 (2010) · low 0 (2009)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · HMX

101in 2025

2007: 42008: 92009: 122010: 142011: 112012: 142013: 82014: 182015: 182016: 362017: 272018: 382019: 272020: 272021: 412022: 462023: 932024: 1002025: 101
2007high 101 (2025) · low 4 (2007)2025

MAUDE reports naming product code HMX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—14
20080—19
20090—012
20100—614
20110—011
20120—1 (1)14
20130—18
20140—018
20150—018
20160—036
20170—027
20180—238
20190—627
20200—027
20210—041
20220—046
20230—093
20240—0100
20250—1101
20260—0—

What is it indicated for?

For irrigation/aspiration during eye surgery

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K970873: Endosoft Soft Tip Needle (20 GA. and 19 GA.).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K970873

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Page last updated Nov 3, 2026