Immulite Cea

K970877510(k) TraditionalCleared Sep 22, 1997196-day reviewClass II21 CFR 866.6010Recalls 3

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Diagnostic Products Corp. · DHX System, Test, Carcinoembryonic Antigen

Cleared on Sep 22, 1997 after a 196-day review. The FDA summary names its predicate without a number. It has been recalled 3 times.

Decided
Sep 22, 1997
Review
196 days
Class
Class II
Product code
DHX
Recalls
3
Predicates
0

The FDA summary names its predicate without a number.

FIG. 1 — Lineage of K970877Source: FDA 510(k) database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DHX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DHX device

  1. #1 K223921 Access CEAscore 6.6 · 3 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—Abbott Laboratories' IMx® CEA
Named without a submission number
—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jan 2, 2018Class IIZ-1678-2018Error in labelingConcentrations for the level of biotin that does not interfere is not currently listed in the instruction for use for the Dimension Vista CTNI, Dimension Vista MMB, Dimension Sirolimus, ADVIA Centaur FOL, ADVIA Centaur aHBcM and the…
May 26, 2005Not classifiedZ-1015-05OtherAdverse trend in stability, controls biased or out of range.
May 3, 2004Not classifiedZ-0972-04OtherInstabililty

No ancestor or descendant has a Class I recall.

How does its category compare?

All DHX devices

DHX System, Test, Carcinoembryonic Antigen: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · DHX

2in 2023

2008: 22009: 12020: 12023: 2
2007high 2 (2008) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DHX

Too few DHX 510(k)s in any year since 2007 to give a median.

Recalls per year · DHX

1in 2015

2010: 12015: 1
2007high 1 (2010) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DHX

19in 2025

2007: 22008: 112009: 202010: 82011: 142012: 142013: 262014: 152015: 332016: 222017: 72018: 202019: 122020: 142021: 112022: 122023: 152024: 152025: 19
2007high 33 (2015) · low 2 (2007)2025

MAUDE reports naming product code DHX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—02
20082—011
20091—020
20100—18
20110—014
20120—014
20130—026
20140—015
20150—133
20160—022
20170—07
20180—020
20190—012
20201—014
20210—011
20220—012
20232—015
20240—015
20250—019
20260—0—

What is it indicated for?

DPC's IMMULITE CEA is intended for use with the IMMULITE Automated Immunoassay Analyzer. The IMMULITE CEA is a solid-phase, chemiluminescent enzyme immunoassay designed for the quantitative detection of carcinoembryonic antigen in human serum. It is intended strictly for in vitro diagnostic use as an aid in the management of cancer patients and in the assessment of prognosis.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K970877: Immulite Cea.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K970877

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Page last updated Nov 3, 2026