510(k) · Cleared
ClearedDigi-Injector
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Medical Instrument Development Laboratories, Inc. · MRH Pump, Infusion, Ophthalmic
Cleared on Sep 19, 1997 after a 179-day review. FDA’s file for it is a 510(k) statement, which names no predicate.
- Decided
- Sep 19, 1997
- Review
- 179 days
- Class
- Class II
- Product code
- MRH
- Recalls
- None
- Predicates
- 0
FDA’s file for it is a 510(k) statement, which names no predicate.
Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in MRH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new MRH device
- #1 K253760 OMNI Ultra Surgical System (1-110)score 14.5 · 10 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA’s file for it is a 510(k) statement, which names no predicate.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All MRH devicesMRH Pump, Infusion, Ophthalmic: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · MRH
1in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · MRH
Too few MRH 510(k)s in any year since 2007 to give a median.
Recalls per year · MRH
No recall names MRH since 2007.
Adverse event reports per year · MRH
14in 2025
MAUDE reports naming product code MRH, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 0 | — | 0 | 0 |
| 2009 | 0 | — | 0 | 0 |
| 2010 | 0 | — | 0 | 0 |
| 2011 | 0 | — | 0 | 0 |
| 2012 | 0 | — | 0 | 0 |
| 2013 | 1 | — | 0 | 0 |
| 2014 | 1 | — | 0 | 0 |
| 2015 | 0 | — | 0 | 0 |
| 2016 | 0 | — | 0 | 0 |
| 2017 | 2 | — | 0 | 28 |
| 2018 | 0 | — | 0 | 1 |
| 2019 | 0 | — | 0 | 2 |
| 2020 | 1 | — | 0 | 6 |
| 2021 | 2 | — | 0 | 2 |
| 2022 | 2 | — | 0 | 16 |
| 2023 | 1 | — | 0 | 31 |
| 2024 | 0 | — | 0 | 20 |
| 2025 | 1 | — | 0 | 14 |
| 2026 | 1 | — | 0 | — |
What is it indicated for?
The Digi-Injector is indicated for use as a general purpose injector of fluids It is to be used with single-use, disposable needles of any gauge size. It is to be used wherever precise control of injection rate or volume is required. The Digi-Injector is also indicated for use for injection of fluids (high or low viscosity) during ophthalmic surgery.
Indications for use read by OCR from a scanned FDA 510(k) statement, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K971067 · printed Nov 4, 2026
Cite this page
510(k) Report. “K971067: Digi-Injector.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K971067
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026