510(k) Report

510(k) · Cleared

Cleared

Interlogics W-Tracker and Wrist Works Software

K971079510(k) TraditionalCleared Jul 9, 1997106-day reviewClass I21 CFR 888.1500

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Interlogics, Inc. · KQX Goniometer, Ac-Powered

Cleared on Jul 9, 1997 after a 106-day review. FDA’s file for it is a 510(k) statement, which names no predicate.

Decided
Jul 9, 1997
Review
106 days
Class
Class I
Product code
KQX
Recalls
None
Predicates
0

FDA’s file for it is a 510(k) statement, which names no predicate.

FIG. 1 — Lineage of K971079Source: FDA 510(k) database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KQX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

How does its category compare?

All KQX devices

KQX Goniometer, Ac-Powered: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · KQX

FDA has decided no KQX device since 2007.

Median 510(k) review, days · KQX

Too few KQX 510(k)s in any year since 2007 to give a median.

Recalls per year · KQX

No recall names KQX since 2007.

Adverse event reports per year · KQX

No MAUDE report names KQX since 2007.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20180—00
20190—00
20200—00
20210—00
20220—00
20230—00
20240—00
20250—00
20260—0—

What is it indicated for?

The W-Tracker is a bi-axial wrist-joint movement assessment device mounted on a forearm and hand. Specifically, it measures angular range of motion and velocity in two planes. The Clinical Analysis protocol requires the subject to perform a series of wrist movements, including wrist flexion/extension and ulnar/radial deviation, each to be performed by the subject at his/her preferred speed. The data obtained during the Clinical Analysis protocol is…

Read the full statement (188 words)

The W-Tracker is a bi-axial wrist-joint movement assessment device mounted on a forearm and hand. Specifically, it measures angular range of motion and velocity in two planes. The Clinical Analysis protocol requires the subject to perform a series of wrist movements, including wrist flexion/extension and ulnar/radial deviation, each to be performed by the subject at his/her preferred speed. The data obtained during the Clinical Analysis protocol is real-time data, and is immediately transferred from the W-Tracker to the computer via an A/D conversion device to a serial port.

The goals of the device when performing the Clinical Analysis protocol is to compile information related to tests devised by the AMA to measure impairment of wrist joints, and to compare performance profiles of normal and injured populations.

The W-Tracker does not initiate or control any movement during a test and it does not induce any forces on the subject. It is, therefore, a passive device. The only forces acting on the subject are the negligible inertial forces of the W-Tracker generated by the subject’s wrist movements. The device is fail-safe in design to obviate safety concerns for the subject.

Indications for use read by OCR from a scanned FDA 510(k) statement, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K971079: Interlogics W-Tracker and Wrist Works Software.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K971079

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Page last updated Nov 3, 2026