510(k) Report

510(k) · Cleared

Cleared

Bard NO-Rinse Hemoconcentrator and Accessory Kit

K971180510(k) TraditionalCleared Jul 24, 1997115-day reviewClass II21 CFR 876.5860

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

C.R. Bard, Inc. · KDI Dialyzer, High Permeability With Or Without Sealed Dialysate System

Cleared on Jul 24, 1997 after a 115-day review. The FDA summary names its predicate without a number. 2 later devices descend from it.

Decided
Jul 24, 1997
Review
115 days
Class
Class II
Product code
KDI
Recalls
None
Predicates
0

2 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 1998: 1 descendant cleared1999: 1 descendant cleared1995200020052010201520202025
  1. This deviceK971180 Bard NO-Rinse Hemoconcentrator and Accessory KitC.R. Bard, Inc. · 1997
  2. Descendant · cites it directly · 1 of its ownK974584 Fresenius F Series Hemoconcentrators…Fresenius USA, Inc. · 1998
  3. Descendant · 2 generations on · 0 of its ownK992275 Fresenius Modified F400 Low Volume Hemoconcentrator F3000 & Modified…Fresenius USA, Inc. · 1999

Most influential descendants

Showing 2 of 2 · See all
  • K974584Fresenius F Series Hemoconcentrators F400,F500,F700,F800,F400TS,F500TS,F700S,F800TSFresenius USA, Inc. · 1998 · cites it directly1descendant
  • K992275Fresenius Modified F400 Low Volume Hemoconcentrator F3000 & Modified F400 Low Vol…Fresenius USA, Inc. · 1999 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K971180Bard NO-Rinse Hemoconcentrator and Accessory KitC.R. Bard, Inc.1997—
+1K974584Fresenius F Series Hemoconcentrators…Fresenius USA, Inc.1998—
+2K992275Fresenius Modified F400 Low Volume Hemoconcentrator F3000 & Modified F400 Low…Fresenius USA, Inc.1999—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
199810
199910
FIG. 1 — Lineage of K971180, 1997–1999Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KDI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KDI device

  1. #1 K243874 FX CorAL 60 (F00012969); FX CorAL 80…score 18.2 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—Fresenius Hemoflow F40 Capillary Dialyzer
Named without a submission number
—
*—Bard Hemoconcentrator with Tubing Set, HC70TS
Named without a submission number
—
*—Research Medical Hemoconcentrator, Biofilter 140
Named without a submission number
—

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K974584Fresenius F Series Hemoconcentrators F400,F500,F700,F800,F400TS,F500TS,F700S,F800TSFresenius USA, Inc.19981

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K974584 (Fresenius USA, Inc., 1998) has gone furthest, with 1 descendant of its own.

How does its category compare?

All KDI devices

KDI Dialyzer, High Permeability With Or Without Sealed Dialysate System: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · KDI

9in 2025

2007: 112008: 62009: 42010: 92011: 52012: 62013: 112014: 82015: 52016: 52017: 82018: 22019: 42020: 92021: 22022: 72023: 72024: 72025: 92026 (partial year): 6
2007high 11 (2007) · low 2 (2018)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KDI

199in 2025

2007: 91 days median2008: 148 days median2009: 236 days median2010: 186 days median2011: 85 days median2012: 153 days median2013: 247 days median2014: 164 days median2015: 69 days median2016: 230 days median2017: 188 days median2019: 263 days median2020: 266 days median2022: 259 days median2023: 157 days median2024: 235 days median2025: 199 days median2026 (partial year): 154 days median
2007high 266 (2020) · low 69 (2015)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KDI

2in 2025

2007: 42009: 32010: 12011: 42012: 12013: 22014: 32015: 52016: 42017: 12018: 12019: 62021: 22022: 172023: 8, 8 Class I2024: 4, 2 Class I2025: 22026 (partial year): 2
2007high 17 (2022) · low 0 (2008)2026

Class I (10 since 2007) Class II/III not classified

Adverse event reports per year · KDI

2,786in 2025

2007: 9162008: 1,0422009: 5222010: 8232011: 2,2702012: 1,7652013: 2,3602014: 6,1542015: 4,1822016: 7662017: 9632018: 1,7162019: 1,5872020: 1,6332021: 1,9442022: 2,1802023: 2,6922024: 2,4412025: 2,786
2007high 6,154 (2014) · low 522 (2009)2025

MAUDE reports naming product code KDI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200711914916
2008614801,042
200942363522
201091861823
201158542,270
2012615311,765
20131124722,360
2014816436,154
201556954,182
201652304766
201781881963
20182—11,716
2019426361,587
2020926601,633
20212—21,944
20227259172,180
202371578 (8)2,692
202472354 (2)2,441
2025919922,786
202661542—

What is it indicated for?

The Bard® No-rinse Hemoconcentrator is intended for the relief

or mitigation of overhydration in patients undergoing

cardiopulmonary procedures and to increase the concentration of

cells and proteins in the blood.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K971180: Bard NO-Rinse Hemoconcentrator and Accessory Kit.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K971180

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026