510(k) Report

510(k) · Cleared

Cleared

Dcat Embolectomy Catheter System

K971314510(k) TraditionalCleared Mar 17, 1998342-day reviewClass II21 CFR 870.5150

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

AngioDynamics, Inc. · DXE Catheter, Embolectomy

Cleared on Mar 17, 1998 after a 342-day review. FDA’s file for it is a 510(k) statement, which names no predicate.

Decided
Mar 17, 1998
Review
342 days
Class
Class II
Product code
DXE
Recalls
None
Predicates
0

FDA’s file for it is a 510(k) statement, which names no predicate.

FIG. 1 — Lineage of K971314Source: FDA 510(k) database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DXE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DXE device

  1. #1 K240078 Fogarty Thru-Lumen Embolectomy Catheterscore 7.9 · 1 generation · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

How does its category compare?

All DXE devices

DXE Catheter, Embolectomy: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · DXE

5in 2024

2008: 12010: 22015: 12017: 22020: 12021: 12022: 12024: 5
2007high 5 (2024) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DXE

173in 2024

2024: 173 days median
2007high 173 (2024)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DXE

1in 2023

2007: 32009: 52010: 12011: 12015: 132021: 4, 4 Class I2022: 32023: 12026 (partial year): 2
2007high 13 (2015) · low 0 (2008)2026

Class I (4 since 2007) Class II/III not classified

Adverse event reports per year · DXE

306in 2025

2007: 1672008: 1342009: 1242010: 1362011: 1642012: 2002013: 1502014: 1922015: 2662016: 7962017: 7702018: 6152019: 5942020: 5472021: 3332022: 4632023: 4362024: 3772025: 306
2007high 796 (2016) · low 124 (2009)2025

MAUDE reports naming product code DXE, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—3167
20081—0134
20090—5124
20102—1136
20110—1164
20120—0200
20130—0150
20140—0192
20151—13266
20160—0796
20172—0770
20180—0615
20190—0594
20201—0547
20211—4 (4)333
20221—3463
20230—1436
202451730377
20250—0306
20260—2—

What is it indicated for?

The ANGIODYNAMICS, Inc. DCAT System is for the percutaneous isolation and aspiration of fresh thrombus from vessels in the vascular system. Additionally, it may also be used for temporary occlusion of blood vessels, isolated infusion of fluids, and blood sampling.

The ANGIODYNAMICS, Inc. Cohn Thrombectomy Catheter is intended to be used for temporary occlusion and removal of thromboemboli from native or synthetic vessels within the arterial circulation.

Indications for use read by OCR from a scanned FDA 510(k) statement, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K971314: Dcat Embolectomy Catheter System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K971314

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Page last updated Nov 3, 2026