# K971414: Zirconia Prozyr Ceramic 12/14 Global Taper (GT) Femoral Heads

- Pathway: 510(k) (Traditional)
- Applicant: Smith & Nephew, Inc., Orthopaedic Div.
- Decided: Jul 16, 1997 after 91 days
- Product code: LZO (Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented)
- Device class: 2
- Regulation: 21 CFR 888.3353
- Recalls of this device: none
- Data: FDA decisions to Oct 25, 2026; recalls to Oct 12, 2026

## Lineage
No predicates in its family tree.
4 later devices descend from it; 1 cites it directly.
0 of 5 devices in its family (counting itself) have a Class I recall.

## Predicates on the family tree (from the FDA summary)
- None. The FDA summary names no predicate by number.

## Most influential descendants
- K211176: Smith & Nephew Hip Systems (2022), 3 descendants of its own
- K240783: Anthology Hip Stems; CPCS Hip Stems; Femoral Heads; R3 Acetabular Liners; Spectron Hip Stems; Synergy Hip Stems (2024), 0 descendants of its own
- K242375: OR3O Dual Mobility System (2024), 0 descendants of its own
- K231448: TANDEM Hip System (2023), 0 descendants of its own

## Indications for use
The Zirconia femoral head components are to be used with other total hip components as part of a total hip arthroplasty. The components are indicated for cemented and uncemented use for individuals undergoing primary and revision surgery where other treatments or devices have failed for rehabilitating hips damaged as a result of trauma, or non-inflammatory degenerative joint disease (NIDJD) or any of its composite diagnoses of osteoarthritis, avascular necrosis, traumatic arthritis, slipped capital epiphysis, fused hip, fracture of the pelvis, and diastrophic variant. Indications also include inflammatory degenerative joint disease including rheumatoid arthritis, arthritis secondary to a variety of diseases and anomalies, and congenital dysplasia; old, remote osteomyelitis with an extended drainage-free period, in which case, the patient should be warned of an above normal danger of infection postoperatively; treatments of nonunion, femoral neck fracture and trochanteric fractures of the proximal femur with heads involvement that are unmanageable using other techniques; endoprosthesis, femoral osteotomy, or Girdlestone resection; fracture-dislocation of the hip; and correction of deformity. The devices are for single use. These head devices may be used with stems that are available with cementless or cement fixation. These heads have not been submitted to the FDA for identical or different intended uses.