# K971452: Multix Top/Pro Radiographic X-Ray Table

- Pathway: 510(k) (Traditional)
- Applicant: Siemens Medical Solutions USA, Inc.
- Decided: May 14, 1997 after 23 days
- Product code: IZZ (Table, Radiographic, Non-Tilting, Powered)
- Device class: 2
- Regulation: 21 CFR 892.1980
- Recalls of this device: 8 (0 Class I)
- Data: FDA decisions to Oct 25, 2026; recalls to Oct 12, 2026

## Lineage
Longest line of descent: 1 generation back to K803130 (1981). 2 ancestors in all.
197 later devices descend from it; 3 cite it directly.
0 of 200 devices in its family (counting itself) have a Class I recall.

## Predicates on the family tree (from the FDA summary)
- K803130: Multix U. Bucky Table X-Ray Unit, Siemens Corp. (1981) Summary page 2.
- K884930: Compax Model 40, 400, 400T, General Electric Co. (1988) Summary page 2.

## Most influential descendants
- K983732: Thorax FD and Multix FD (1999), 187 descendants of its own
- K992794: Stingray DR, Model 1 (1999), 103 descendants of its own
- K013826: Axiom Aristos FX (Multi Purpose Radiography System) (2002), 81 descendants of its own
- K061054: Axiom Aristos FX Plus (2006), 80 descendants of its own
- K062623: Axiom Luminos DRF (2007), 78 descendants of its own

## Recalls of this device
- May 31, 2024 · Class II · Z-2180-2024: Short circuit in the power supply unit (PSU) of the Touch Display may lead to overheating and fire
- May 31, 2024 · Class II · Z-2186-2024: Short circuit in the power supply unit (PSU) of the Touch Display may lead to overheating and fire
- May 31, 2024 · Class II · Z-2183-2024: Short circuit in the power supply unit (PSU) of the Touch Display may lead to overheating and fire
- May 31, 2024 · Class II · Z-2187-2024: Short circuit in the power supply unit (PSU) of the Touch Display may lead to overheating and fire
- May 31, 2024 · Class II · Z-2182-2024: Short circuit in the power supply unit (PSU) of the Touch Display may lead to overheating and fire
- May 31, 2024 · Class II · Z-2181-2024: Short circuit in the power supply unit (PSU) of the Touch Display may lead to overheating and fire
- Aug 6, 2018 · Class II · Z-0298-2019: In rare cases of high clinical workload, the steel cables inside the lifting column of the overhead tube, which are designed to take the load, may rapture without triggering the safety lock. This coul
- Mar 5, 2014 · Class II · Z-1460-2014: There is a potential issue and possible hazard to patients when using the AXIOM Vertix MD Trauma systems. In rare cases, steel ropes inside the lift column of the system can be defective without trigg

## Indications for use
The Multix TOP/ PRO Radiographic X-ray Table is a patient table used in conjunction with the Siemens Multix PRO - and TOP Systems radiographic devices. The table allows for radiographic exposures of the entire body, specifically the skull, spinal column, chest and abdomen, as well as the extremities. Applications can be performed with sitting, standing or prone patient positioning.