510(k) · Cleared
ClearedLaparoscopic Bladder Neck Suspension Kit
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Louisville Laboratories, Inc. · HET Laparoscope, Gynecologic (And Accessories)
Cleared on Jul 22, 1997 as substantially equivalent to K963076 (Louisville Laboratories, Inc., 1997) and 1 other predicate after a 68-day review. Its family tree reaches back 1 generation to 1994. 5 later devices descend from it.
- Decided
- Jul 22, 1997
- Review
- 68 days
- Class
- Class II
- Product code
- HET
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 1 generation to K932553 (1994). 2 ancestors in all. 5 later devices descend from it, 2 citing it directly.
- Root · 1 generation backK932553 Disposable Suture Placement SystemLaurus Medical Corp. · 1994 · Recalled
- This deviceK971797 Laparoscopic Bladder Neck Suspension KitLouisville Laboratories, Inc. · 1997
- Descendant · cites it directly · 3 of its ownK011190 Surx Radiofrequency Electrosurgical Generator System and Accessories…Surx, Inc. · 2002
- Descendant · 2 generations on · 2 of its ownK020126 Modification to Surx Radiofrequency Electrosurgical Generator System…Surx, Inc. · 2002
- Descendant · 2 generations on · 1 of its ownK020952 Surx RF SystemSurx, Inc. · 2002
- Descendant · 3 generations on · 0 of its ownK042132 Novasys Transurethral RF SystemNovasys Medical, Inc. · 2004 · Recalled
- Descendant · cites it directly · 0 of its ownK982626 Urethropexy Suture Placement Kit Model Numbers UM-300, MW-100…Medworks Corp. · 1998
Most influential descendants
Showing 5 of 5 · See all- K011190Surx Radiofrequency Electrosurgical Generator System and Accessories (Surx LP System)Surx, Inc. · 2002 · cites it directly3descendants
- K020126Modification to Surx Radiofrequency Electrosurgical Generator System and Accessories…Surx, Inc. · 2002 · 2 generations on2descendants
- K020952Surx RF SystemSurx, Inc. · 2002 · 2 generations on1descendant
- K042132Novasys Transurethral RF SystemNovasys Medical, Inc. · 2004 · 3 generations on0descendants
- K982626Urethropexy Suture Placement Kit Model Numbers UM-300, MW-100, Mini-Laparotomy MMK Kit…Medworks Corp. · 1998 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K932553 | Disposable Suture Placement System | Laurus Medical Corp. | 1994 | 2 |
| 0 (this device) | K971797 | Laparoscopic Bladder Neck Suspension Kit | Louisville Laboratories, Inc. | 1997 | — |
| +1 | K011190 | Surx Radiofrequency Electrosurgical Generator System and Accessories (Surx LP… | Surx, Inc. | 2002 | — |
| +2 | K020126 | Modification to Surx Radiofrequency Electrosurgical Generator System and… | Surx, Inc. | 2002 | — |
| +2 | K020952 | Surx RF System | Surx, Inc. | 2002 | — |
| +3 | K042132 | Novasys Transurethral RF System | Novasys Medical, Inc. | 2004 | 1 |
| +1 | K982626 | Urethropexy Suture Placement Kit Model Numbers UM-300, MW-100, Mini-Laparotomy… | Medworks Corp. | 1998 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1997 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1998 | 1 | 0 |
| 2002 | 3 | 0 |
| 2004 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in HET? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new HET device
- #1 K250939 SIRIUS Endoscope System (PR-SI-1230)score 12.9 · 11 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (3)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K963076 | Laparoscopic Bone Anchored Urethropexy Instrument TraySummary page 2…k Suspension Kit is substantially equivalent to several devices on the market such as the Louisville laboratories Laparoscopic Bone Anchored Urethropexy Instrument Tray (K963076), the Laurus Medical Suturing System (K932553) and several surgical techniques that have been performed for over forty years. Lo… | 1997 |
| * | K932553 | Disposable Suture Placement SystemSummary page 2…o several devices on the market such as the Louisville laboratories Laparoscopic Bone Anchored Urethropexy Instrument Tray (K963076), the Laurus Medical Suturing System (K932553) and several surgical techniques that have been performed for over forty years. Louisville Laboratories, Inc. Laparoscopic Suspe… | 1994 |
| * | — | surgical techniques that have been performed for over forty years Named without a submission number |
What descends from it? (5)
2 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
How does its category compare?
All HET devicesHET Laparoscope, Gynecologic (And Accessories): FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · HET
2in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · HET
269in 2021
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · HET
4in 2023
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · HET
4,513in 2025
MAUDE reports naming product code HET, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 181 |
| 2008 | 3 | 176 | 4 | 359 |
| 2009 | 1 | — | 1 | 403 |
| 2010 | 1 | — | 0 | 214 |
| 2011 | 2 | — | 0 | 417 |
| 2012 | 2 | — | 0 | 1,118 |
| 2013 | 2 | — | 0 | 1,035 |
| 2014 | 0 | — | 0 | 175 |
| 2015 | 2 | — | 1 | 124 |
| 2016 | 0 | — | 0 | 205 |
| 2017 | 2 | — | 0 | 89 |
| 2018 | 1 | — | 0 | 53 |
| 2019 | 2 | — | 0 | 44 |
| 2020 | 2 | — | 0 | 49 |
| 2021 | 4 | 269 | 0 | 132 |
| 2022 | 1 | — | 1 | 216 |
| 2023 | 0 | — | 4 | 824 |
| 2024 | 0 | — | 0 | 3,496 |
| 2025 | 2 | — | 0 | 4,513 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
The Louisville Laboratories, Inc. Laparoscopic Bladder Neck Suspension Kit is indicated for
urethropexy procedures for bladder neck suspension to correct female stress incontinence due
to urethral hypermobility.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K971797 · printed Nov 4, 2026
Cite this page
510(k) Report. “K971797: Laparoscopic Bladder Neck Suspension Kit.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K971797
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026