Maersk Medical Pureline Comfort Subcutaneous Infusion Set

K972135510(k) TraditionalCleared Aug 26, 199781-day reviewClass II21 CFR 880.5440Recalls 16

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

P/L Biomedical · FPA Set, Administration, Intravascular

Cleared on Aug 26, 1997 after an 81-day review. The summary cites one number, which could not be confirmed as its predicate (see the table below). 1 of the 23 devices in its family, counting itself, has a Class I recall. 22 later devices descend from it. It has been recalled 16 times.

Decided
Aug 26, 1997
Review
81 days
Class
Class II
Product code
FPA
Recalls
16
Predicates
1

22 later devices descend from it, 8 citing it directly. 1 of the 23 devices in this family, counting this one, has a Class I recall.

Descendants, by year cleared 2006: 1 descendant cleared2002: 4 descendants cleared2005: 1 descendant cleared2004: 1 descendant cleared1999: 1 descendant cleared2003: 2 descendants cleared2017: 1 descendant cleared, 1 with a Class I recall12018: 1 descendant cleared2012: 2 descendants cleared2013: 1 descendant cleared2019: 1 descendant cleared2016: 1 descendant cleared2025: 3 descendants cleared2021: 1 descendant cleared2026: 1 descendant cleared1995200020052010201520202025
  1. This deviceK972135 Maersk Medical Pureline Comfort Subcutaneous Infusion SetP/L Biomedical · 1997
  2. Descendant · cites it directly · 14 of its ownK032854 Unomedical Monica Infusion SetUnomedical A/S · 2003 · Recalled
  3. Descendant · 2 generations on · 3 of its ownK173879 MiniMed Mio Advance infusion setUnomedical A/S · 2018
  4. Descendant · cites it directly · 3 of its ownK014062 Simplicity Easy Access Infusion SetSterling Medivations, Inc. · 2002
  5. Descendant · cites it directly · 2 of its ownK061374 Intuition Infusion SetsUnomedical A/S · 2006
  6. Descendant · cites it directly · 2 of its ownK041545 Contact DetachUnomedical A/S · 2004 · Recalled

Showing 5 of 22 descendants. See all descendants

Descendants cleared per year

1999: 12002: 42003: 22004: 12005: 12006: 12012: 22013: 12016: 12017: 12018: 12019: 12021: 12025: 32026: 1
1999high 4 (2002) · low 0 (2000)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 22 · See all
  • K032854Unomedical Monica Infusion SetUnomedical A/S · 2003 · cites it directly14descendants
  • K173879MiniMed Mio Advance infusion setUnomedical A/S · 2018 · 2 generations on3descendants
  • K014062Simplicity Easy Access Infusion SetSterling Medivations, Inc. · 2002 · cites it directly3descendants
  • K061374Intuition Infusion SetsUnomedical A/S · 2006 · cites it directly2descendants
  • K041545Contact DetachUnomedical A/S · 2004 · cites it directly2descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K972135Maersk Medical Pureline Comfort Subcutaneous Infusion SetP/L Biomedical1997—
+1K032854Unomedical Monica Infusion SetUnomedical A/S20031
+2K173879MiniMed Mio Advance infusion setUnomedical A/S2018—
+1K014062Simplicity Easy Access Infusion SetSterling Medivations, Inc.2002—
+1K061374Intuition Infusion SetsUnomedical A/S2006—
+1K041545Contact DetachUnomedical A/S20043

Descendants by year cleared

Year clearedDevicesWith a Class I recall
199910
200240
200320
200410
200510
200610
201220
201310
201610
201711
201810
201910
202110
202530
202610
FIG. 1 — Lineage of K972135, 1997–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FPA device

  1. #1 K243841 Sparta Infusion Set for Insulinscore 13.4 · 3 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary; numbers the summary cites that cannot be its predicate are marked – and kept off the family tree.

TypeNumberDeviceApplicantDecidedRecalls
Kept off the family treeK950018FDA’s K950018 is Cambridge Heart CH 2000 Stress Test System
Not matched in our reading of the summary (scans can blur digits), so it is kept off the family tree
Cambridge Heart, Inc.1996—

What descends from it? (22)

See all 22

8 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K032854Unomedical Monica Infusion SetUnomedical A/S200314
K014062Simplicity Easy Access Infusion SetSterling Medivations, Inc.20023
K061374Intuition Infusion SetsUnomedical A/S20062
K041545Contact DetachUnomedical A/S20042
K051264Comfort and Inset Subcutaneous Infusion Sets for Use with Abbott Infusion PumpsUnomedical A/S20051
K162812Unomedical Comfort Subcutaneous Infusion Set, Unomedical Comfort Short Subcutaneous… Class IUnomedical A/S20170
K032485Medtronic Minimed Countach Infusion Set, Model 313Medtronic Minimed20030
K984561Subcutaneous Infusion Sets, MSR Model a & BMsr, Inc.19990

Has anything in its family been recalled? (1 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Nov 20, 2014Class IIZ-0885-2015Device DesignRoche Diabetes Care was informed by UnoMedical, the Manufacturer of ACCU-CHEK Tender I and ACCU-CHEK Tender II infusion sets, about potential for the the tubing of the infusion set to become detached at the connect/disconnect location on…
Nov 20, 2014Class IIZ-0887-2015Device DesignRoche Diabetes Care was informed by UnoMedical, the Manufacturer of ACCU-CHEK Tender I and ACCU-CHEK Tender II infusion sets, about potential for the the tubing of the infusion set to become detached at the connect/disconnect location on…
Nov 20, 2014Class IIZ-0884-2015Device DesignRoche Diabetes Care was informed by UnoMedical, the Manufacturer of ACCU-CHEK Tender I and ACCU-CHEK Tender II infusion sets, about potential for the the tubing of the infusion set to become detached at the connect/disconnect location on…
Nov 20, 2014Class IIZ-0888-2015Device DesignRoche Diabetes Care was informed by UnoMedical, the Manufacturer of ACCU-CHEK Tender I and ACCU-CHEK Tender II infusion sets, about potential for the the tubing of the infusion set to become detached at the connect/disconnect location on…
Nov 20, 2014Class IIZ-0891-2015Device DesignRoche Diabetes Care was informed by UnoMedical, the Manufacturer of ACCU-CHEK Tender I and ACCU-CHEK Tender II infusion sets, about potential for the the tubing of the infusion set to become detached at the connect/disconnect location on…
Nov 20, 2014Class IIZ-0883-2015Device DesignRoche Diabetes Care was informed by UnoMedical, the Manufacturer of ACCU-CHEK Tender I and ACCU-CHEK Tender II infusion sets, about potential for the the tubing of the infusion set to become detached at the connect/disconnect location on…
Nov 20, 2014Class IIZ-0886-2015Device DesignRoche Diabetes Care was informed by UnoMedical, the Manufacturer of ACCU-CHEK Tender I and ACCU-CHEK Tender II infusion sets, about potential for the the tubing of the infusion set to become detached at the connect/disconnect location on…
Nov 20, 2014Class IIZ-0889-2015Device DesignRoche Diabetes Care was informed by UnoMedical, the Manufacturer of ACCU-CHEK Tender I and ACCU-CHEK Tender II infusion sets, about potential for the the tubing of the infusion set to become detached at the connect/disconnect location on…
Nov 20, 2014Class IIZ-0890-2015Device DesignRoche Diabetes Care was informed by UnoMedical, the Manufacturer of ACCU-CHEK Tender I and ACCU-CHEK Tender II infusion sets, about potential for the the tubing of the infusion set to become detached at the connect/disconnect location on…
Nov 20, 2014Class IIZ-0892-2015Device DesignRoche Diabetes Care was informed by UnoMedical, the Manufacturer of ACCU-CHEK Tender I and ACCU-CHEK Tender II infusion sets, about potential for the the tubing of the infusion set to become detached at the connect/disconnect location on…
Nov 20, 2014Class IIZ-0893-2015Device DesignRoche Diabetes Care was informed by UnoMedical, the Manufacturer of ACCU-CHEK Tender I and ACCU-CHEK Tender II infusion sets, about potential for the the tubing of the infusion set to become detached at the connect/disconnect location on…
Nov 20, 2014Class IIZ-0894-2015Device DesignRoche Diabetes Care was informed by UnoMedical, the Manufacturer of ACCU-CHEK Tender I and ACCU-CHEK Tender II infusion sets, about potential for the the tubing of the infusion set to become detached at the connect/disconnect location on…
Nov 7, 2014Class IIZ-0359-2017Device DesignTubing detachment
Nov 7, 2014Class IIZ-0357-2017Device DesignTubing detachment
Nov 7, 2014Class IIZ-0358-2017Device DesignTubing detachment
Nov 7, 2014Class IIZ-0355-2017Device DesignTubing detachment

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K162812Unomedical Comfort Subcutaneous Infusion Set, Unomedical Comfort Short Subcutaneous Infusion Set, Unomedical…Unomedical A/S · 2017 · Cites it directly · ◆ in the 2017 descendants bar of FIG. 13 Class I recalls

What does this lineage say?

  • Of its descendants, K032854 (Unomedical A/S, 2003) has gone furthest, with 14 descendants of its own.

How does its category compare?

All FPA devices

FPA Set, Administration, Intravascular: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · FPA

11in 2025

2007: 162008: 182009: 102010: 232011: 122012: 212013: 132014: 222015: 172016: 122017: 172018: 42019: 72020: 102021: 132022: 142023: 142024: 72025: 112026 (partial year): 5
2007high 23 (2010) · low 4 (2018)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FPA

225in 2025

2007: 75 days median2008: 89 days median2009: 166 days median2010: 120 days median2011: 87 days median2012: 96 days median2013: 90 days median2014: 89 days median2015: 123 days median2016: 195 days median2017: 240 days median2018: 177 days median2019: 161 days median2020: 327 days median2021: 186 days median2022: 213 days median2023: 340 days median2024: 244 days median2025: 225 days median2026 (partial year): 266 days median
2007high 340 (2023) · low 75 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FPA

98in 2025

2007: 172008: 152009: 1662010: 582011: 282012: 16, 4 Class I2013: 642014: 242015: 62016: 102017: 132018: 42019: 132020: 1072021: 12022: 9, 5 Class I2023: 12, 4 Class I2024: 13, 1 Class I2025: 98, 1 Class I2026 (partial year): 10, 2 Class I
2007high 166 (2009) · low 1 (2021)2026

Class I (17 since 2007) Class II/III not classified

Adverse event reports per year · FPA

34,506in 2025

2007: 1,4992008: 1,9412009: 2,5122010: 2,5372011: 4,4072012: 4,9302013: 4,6512014: 4,6952015: 6,6252016: 8,4702017: 6,4622018: 6,5742019: 11,2272020: 9,5632021: 10,4142022: 13,3932023: 10,9162024: 47,2102025: 34,506
2007high 47,210 (2024) · low 1,499 (2007)2025

MAUDE reports naming product code FPA, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071675171,499
20081889151,941
2009101661662,512
201023120582,537
20111287284,407
2012219616 (4)4,930
20131390644,651
20142289244,695
20151712366,625
201612195108,470
201717240136,462
2018417746,574
201971611311,227
2020103271079,563
202113186110,414
2022142139 (5)13,393
20231434012 (4)10,916
2024724413 (1)47,210
20251122598 (1)34,506
2026526610 (2)—

What is it indicated for?

The Subcutaneous Infusion Sets with indwelling Catheters are indicated for the infusion and/or injection of fluids into the body below the surface of the skin.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K972135: Maersk Medical Pureline Comfort Subcutaneous Infusion Set.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K972135

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026