510(k) · Cleared
ClearedMTM Bioscanner 1000 Test System Consisting of MTM Bioscanner 1000 Meter, MTM Bioscanner G Test Strip, Norman Glucose Con
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Polymer Technology Systems, Inc. · CGA Glucose Oxidase, Glucose
Cleared on Jan 22, 1998 after a 190-day review. FDA’s file for it is a 510(k) statement, which names no predicate. 12 later devices descend from it.
- Decided
- Jan 22, 1998
- Review
- 190 days
- Class
- Class II
- Product code
- CGA
- Recalls
- None
- Predicates
- 0
12 later devices descend from it, 3 citing it directly.
- This deviceK972669 MTM Bioscanner 1000 Test System Consisting of MTM Bioscanner 1000…Polymer Technology Systems, Inc. · 1998
- Descendant · cites it directly · 9 of its ownK013173 Bioscanner Plus; Lipid Panel Test StripsPolymer Technology Systems, Inc. · 2001 · Recalled
- Descendant · 2 generations on · 7 of its ownK022898 PTS Panels Lipid Panel Test StripsPolymer Technology Systems, Inc. · 2002 · Recalled
- Descendant · cites it directly · 7 of its ownK014099 Bioscanner PlusPolymer Technology Systems, Inc. · 2001
- Descendant · 2 generations on · 6 of its ownK140068 Cardiochek Plus Test System, Cardiochek Home Test SystemPolymer Technology Systems, Inc. · 2015 · Recalled
- Descendant · 3 generations on · 1 of its ownK163406 Mission Cholesterol Monitoring System, Mission Cholesterol Pro…ACON Laboratories, Inc. · 2017
Showing 5 of 12 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 12 · See all- K013173Bioscanner Plus; Lipid Panel Test StripsPolymer Technology Systems, Inc. · 2001 · cites it directly9descendants
- K022898PTS Panels Lipid Panel Test StripsPolymer Technology Systems, Inc. · 2002 · 2 generations on7descendants
- K014099Bioscanner PlusPolymer Technology Systems, Inc. · 2001 · cites it directly7descendants
- K140068Cardiochek Plus Test System, Cardiochek Home Test SystemPolymer Technology Systems, Inc. · 2015 · 2 generations on6descendants
- K163406Mission Cholesterol Monitoring System, Mission Cholesterol Pro Monitoring SystemACON Laboratories, Inc. · 2017 · 3 generations on1descendant
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K972669 | MTM Bioscanner 1000 Test System Consisting of MTM Bioscanner 1000 Meter, MTM… | Polymer Technology Systems, Inc. | 1998 | — |
| +1 | K013173 | Bioscanner Plus; Lipid Panel Test Strips | Polymer Technology Systems, Inc. | 2001 | 1 |
| +2 | K022898 | PTS Panels Lipid Panel Test Strips | Polymer Technology Systems, Inc. | 2002 | 1 |
| +1 | K014099 | Bioscanner Plus | Polymer Technology Systems, Inc. | 2001 | — |
| +2 | K140068 | Cardiochek Plus Test System, Cardiochek Home Test System | Polymer Technology Systems, Inc. | 2015 | 4 |
| +3 | K163406 | Mission Cholesterol Monitoring System, Mission Cholesterol Pro Monitoring System | ACON Laboratories, Inc. | 2017 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2001 | 2 | 0 |
| 2002 | 1 | 0 |
| 2004 | 1 | 0 |
| 2015 | 2 | 0 |
| 2016 | 2 | 0 |
| 2017 | 1 | 0 |
| 2018 | 1 | 0 |
| 2022 | 2 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in CGA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new CGA device
- #1 K252488 ABL90 FLEX PLUS Systemscore 12.8 · 6 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA’s file for it is a 510(k) statement, which names no predicate.
What descends from it? (12)
See all 123 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K013173 (Polymer Technology Systems, Inc., 2001) has gone furthest, with 9 descendants of its own.
How does its category compare?
All CGA devicesCGA Glucose Oxidase, Glucose: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · CGA
2in 2024
2026 to Oct 25, outlined.
Median 510(k) review, days · CGA
249in 2023
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · CGA
3in 2023
Class I (2 since 2007) Class II/III not classified
Adverse event reports per year · CGA
59in 2025
MAUDE reports naming product code CGA, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 7 | 122 | 2 | 29 |
| 2008 | 6 | 56 | 2 | 37 |
| 2009 | 10 | 155 | 4 | 75 |
| 2010 | 8 | 122 | 6 | 172 |
| 2011 | 9 | 217 | 3 | 423 |
| 2012 | 10 | 123 | 0 | 233 |
| 2013 | 3 | 441 | 3 | 172 |
| 2014 | 5 | 265 | 2 | 122 |
| 2015 | 4 | 150 | 6 (2) | 155 |
| 2016 | 4 | 157 | 2 | 36 |
| 2017 | 2 | — | 0 | 92 |
| 2018 | 2 | — | 0 | 69 |
| 2019 | 2 | — | 1 | 116 |
| 2020 | 2 | — | 0 | 68 |
| 2021 | 1 | — | 0 | 48 |
| 2022 | 1 | — | 0 | 272 |
| 2023 | 4 | 249 | 3 | 1,141 |
| 2024 | 2 | — | 0 | 266 |
| 2025 | 0 | — | 0 | 59 |
| 2026 | 1 | — | 0 | — |
What is it indicated for?
Polymer Technology Systems, Inc. intends to introduce into commercial distribution the
MTM BioScanner 1000 Test System for the quantitative determination of glucose in human whole blood when used with the MTM BioScanner G Test Strip. This Monitoring System is intended to be used to assist the patient and healthcare professional in the management of diabetes.
Indications for use read by OCR from a scanned FDA 510(k) statement, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K972669 · printed Nov 4, 2026
Cite this page
510(k) Report. “K972669: MTM Bioscanner 1000 Test System Consisting of MTM Bioscanner 1000 Meter, MTM Bioscanner G Test Strip, Norman Glucose Con.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K972669
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026