Percu Surge, Inc. · MJN Catheter, Intravascular Occluding, Temporary

Cleared on Mar 11, 1998 after a 229-day review. FDA’s file for it is a 510(k) statement, which names no predicate. 3 later devices descend from it.

Decided
Mar 11, 1998
Review
229 days
Class
Class II
Product code
MJN
Recalls
None
Predicates
0

3 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 2004: 1 descendant cleared2006: 1 descendant cleared2008: 1 descendant cleared1995200020052010201520202025
  1. This deviceK972777 Temporary Occlusion Balloon SystemPercu Surge, Inc. · 1998
  2. Descendant · cites it directly · 2 of its ownK031357 Guarddog Occlusion System, Occlusion Guidewire, 300 CM, Guarddog…Possis Medical, Inc. · 2004
  3. Descendant · 2 generations on · 1 of its ownK062220 Modification to Guarddog Occlusion SystemPossis Medical, Inc. · 2006
  4. Descendant · 3 generations on · 0 of its ownK081454 Guarddog Occlusion Guidewire, Inflation DevicePossis Medical, Inc. · 2008

Most influential descendants

Showing 3 of 3 · See all
  • K031357Guarddog Occlusion System, Occlusion Guidewire, 300 CM, Guarddog Occlusion System…Possis Medical, Inc. · 2004 · cites it directly2descendants
  • K062220Modification to Guarddog Occlusion SystemPossis Medical, Inc. · 2006 · 2 generations on1descendant
  • K081454Guarddog Occlusion Guidewire, Inflation DevicePossis Medical, Inc. · 2008 · 3 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K972777Temporary Occlusion Balloon SystemPercu Surge, Inc.1998—
+1K031357Guarddog Occlusion System, Occlusion Guidewire, 300 CM, Guarddog Occlusion…Possis Medical, Inc.2004—
+2K062220Modification to Guarddog Occlusion SystemPossis Medical, Inc.2006—
+3K081454Guarddog Occlusion Guidewire, Inflation DevicePossis Medical, Inc.2008—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200410
200610
200810
FIG. 1 — Lineage of K972777, 1998–2008Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MJN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MJN device

  1. #1 K243795 pREBOA-PRO Catheterscore 12.1 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it? (3)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K031357Guarddog Occlusion System, Occlusion Guidewire, 300 CM, Guarddog Occlusion System…Possis Medical, Inc.20042

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K031357 (Possis Medical, Inc., 2004) has gone furthest, with 2 descendants of its own.

How does its category compare?

All MJN devices

MJN Catheter, Intravascular Occluding, Temporary: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · MJN

2in 2025

2007: 22008: 32009: 52010: 52011: 42012: 22013: 42014: 22015: 42016: 32017: 32018: 32019: 32020: 42021: 42022: 22023: 12025: 2
2007high 5 (2009) · low 0 (2024)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MJN

116in 2021

2008: 153 days median2009: 39 days median2010: 30 days median2011: 69 days median2013: 87 days median2015: 245 days median2016: 110 days median2017: 54 days median2018: 63 days median2019: 117 days median2020: 64 days median2021: 116 days median
2007high 245 (2015) · low 30 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MJN

1in 2020

2008: 22010: 12011: 12013: 82015: 12016: 22018: 12020: 1
2007high 8 (2013) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MJN

194in 2025

2007: 252008: 262009: 252010: 352011: 922012: 532013: 762014: 1002015: 902016: 712017: 1572018: 1072019: 1392020: 1572021: 1582022: 1482023: 1812024: 2242025: 194
2007high 224 (2024) · low 25 (2007)2025

MAUDE reports naming product code MJN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—025
20083153226
2009539025
2010530135
2011469192
20122—053
2013487876
20142—0100
20154245190
20163110271
20173540157
20183631107
201931170139
20204641157
202141160158
20222—0148
20231—0181
20240—0224
20252—0194
20260—0—

What is it indicated for?

The PercuSurge Temporary Occlusion Balloon (TOB) System is indicated for use in the peripheral vasculature to facilitate the localized infusion of therapeutic or diagnostic fluids with or without vessel occlusion.

The safety and effectiveness of this device have not been established in the coronary, cerebral, or carotid vasculature (see WARNINGS).

Indications for use read by OCR from a scanned FDA 510(k) statement, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K972777: Temporary Occlusion Balloon System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K972777

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026