510(k) · Cleared
ClearedUltra-Fine Diathermy Loop and Coagulation Balls
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Rocket Medical Plc · KNF Coagulator-Cutter, Endoscopic, Unipolar (And Accessories)
Cleared on Feb 11, 1998 after a 194-day review. The FDA summary names no predicate by number.
- Decided
- Feb 11, 1998
- Review
- 194 days
- Class
- Class II
- Product code
- KNF
- Recalls
- None
- Predicates
- 0
The FDA summary names no predicate by number.
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in KNF? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new KNF device
- #1 K240503 Sonata Transcervical Fibroid Ablation System 2.2score 13.7 · 11 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
The FDA summary names no predicate by number.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All KNF devicesKNF Coagulator-Cutter, Endoscopic, Unipolar (And Accessories): FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · KNF
1in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · KNF
Too few KNF 510(k)s in any year since 2007 to give a median.
Recalls per year · KNF
1in 2013
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · KNF
93in 2025
MAUDE reports naming product code KNF, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 1 | — | 0 | 0 |
| 2008 | 0 | — | 0 | 2 |
| 2009 | 0 | — | 3 | 1 |
| 2010 | 1 | — | 0 | 14 |
| 2011 | 0 | — | 0 | 15 |
| 2012 | 1 | — | 0 | 4 |
| 2013 | 1 | — | 1 | 24 |
| 2014 | 1 | — | 0 | 8 |
| 2015 | 0 | — | 0 | 7 |
| 2016 | 0 | — | 0 | 9 |
| 2017 | 0 | — | 0 | 22 |
| 2018 | 1 | — | 0 | 13 |
| 2019 | 0 | — | 0 | 18 |
| 2020 | 1 | — | 0 | 19 |
| 2021 | 1 | — | 0 | 9 |
| 2022 | 1 | — | 0 | 16 |
| 2023 | 1 | — | 0 | 33 |
| 2024 | 1 | — | 0 | 13 |
| 2025 | 1 | — | 0 | 93 |
| 2026 | 1 | — | 0 | — |
What is it indicated for?
Large Loop Excision of the Transformation zone in the Diagnosis and treatment of some Cervical Intraepithelial Neoplasias (CIN I, IL, III) and Cervical Dysplasia
Extrenal Anogenital Lesions.
Cervical Conizations.
Large Vaginal Intraepithelial Neoplastic (VAIN) Lesions.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K972856 · printed Nov 6, 2026
Cite this page
510(k) Report. “K972856: Ultra-Fine Diathermy Loop and Coagulation Balls.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K972856
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026