Espe GmbH & Co. Kg. · EBF Material, Tooth Shade, Resin
Cleared on Oct 2, 1997 as substantially equivalent to K934978 (Ivoclar North America, Inc., 1993) and 1 other predicate after a 58-day review. Its family tree reaches back 1 generation to 1993. 1 later device descends from it.
- Decided
- Oct 2, 1997
- Review
- 58 days
- Class
- Class II
- Product code
- EBF
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 1 generation to K926418 (1993). 2 ancestors in all. 1 later device descends from it, 1 citing it directly.
Most influential descendants
Showing 1 of 1 · See all- K990982Cavit LCEspe Dental AG · 1999 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K926418 | CLIP | Voco GmbH | 1993 | — |
| 0 (this device) | K972892 | Cavit-LC | Espe GmbH & Co. Kg. | 1997 | — |
| +1 | K990982 | Cavit LC | Espe Dental AG | 1999 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1993 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1999 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in EBF? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new EBF device
- #1 K202846 Tera Harzscore 18.5 · 7 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K934978 | Fermit N Light-Curing Temporary Filling MaterialSummary page 1…ry crowns and bridges. ESPE is claiming substantial equivalence to the previously cleared temporary filling materials Fermit-N Light-Curing Temporary Filling Material (K934978) and Clip® (K926418). Cavit*LC, Fermit-N, and Clip® have similar intended uses and Cavit®-LC and Fermit-N have similar principal… | 1993 |
| * | K926418 | CLIPSummary page 1…es. ESPE is claiming substantial equivalence to the previously cleared temporary filling materials Fermit-N Light-Curing Temporary Filling Material (K934978) and Clip® (K926418). Cavit*LC, Fermit-N, and Clip® have similar intended uses and Cavit®-LC and Fermit-N have similar principal ingredient compositi… | 1993 |
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K990982 | Cavit LC | 1999 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
How does its category compare?
All EBF devicesEBF Material, Tooth Shade, Resin: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · EBF
15in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · EBF
43in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · EBF
1in 2020
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · EBF
1in 2025
MAUDE reports naming product code EBF, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 19 | 49 | 1 | 6 |
| 2008 | 14 | 79 | 42 | 10 |
| 2009 | 20 | 84 | 1 | 8 |
| 2010 | 19 | 75 | 6 | 31 |
| 2011 | 19 | 81 | 7 | 31 |
| 2012 | 11 | 86 | 0 | 62 |
| 2013 | 13 | 153 | 0 | 246 |
| 2014 | 10 | 112 | 0 | 195 |
| 2015 | 17 | 123 | 0 | 119 |
| 2016 | 20 | 205 | 0 | 143 |
| 2017 | 15 | 108 | 4 | 42 |
| 2018 | 15 | 115 | 0 | 8 |
| 2019 | 17 | 159 | 2 | 11 |
| 2020 | 15 | 190 | 1 | 2 |
| 2021 | 13 | 178 | 0 | 2 |
| 2022 | 17 | 63 | 0 | 2 |
| 2023 | 9 | 87 | 0 | 8 |
| 2024 | 18 | 120 | 0 | 5 |
| 2025 | 15 | 43 | 0 | 1 |
| 2026 | 16 | 59 | 2 | — |
What is it indicated for?
Temporary fillings for inlay and onlay preparations
Temporary fillings of cavities
Temporary filling of implant sites
Relining of prefabricated temporary crowns and bridges
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K972892 · printed Nov 4, 2026
Cite this page
510(k) Report. “K972892: Cavit-LC.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K972892
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026