510(k) · Cleared
ClearedPrisma
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Siemens Hearing Instruments, Inc. · ESD Hearing Aid, Air-Conduction, Prescription
Cleared on Sep 5, 1997 after a 24-day review. The FDA summary names no predicate by number.
- Decided
- Sep 5, 1997
- Review
- 24 days
- Class
- Class I
- Product code
- ESD
- Recalls
- None
- Predicates
- 0
The FDA summary names no predicate by number.
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in ESD? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new ESD device
- #1 K232999 Lyric4 Hearing Aidscore 8.4 · 5 generations · no Class I recall
What was it cleared against?
The FDA summary names no predicate by number.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All ESD devicesESD Hearing Aid, Air-Conduction, Prescription: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · ESD
1in 2024
2026 to Oct 25, outlined.
Median 510(k) review, days · ESD
Too few ESD 510(k)s in any year since 2007 to give a median.
Recalls per year · ESD
2in 2019
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · ESD
53in 2025
MAUDE reports naming product code ESD, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 13 |
| 2008 | 1 | — | 0 | 13 |
| 2009 | 0 | — | 0 | 3 |
| 2010 | 0 | — | 1 | 1 |
| 2011 | 0 | — | 0 | 3 |
| 2012 | 0 | — | 0 | 6 |
| 2013 | 1 | — | 0 | 37 |
| 2014 | 0 | — | 0 | 4 |
| 2015 | 0 | — | 0 | 6 |
| 2016 | 0 | — | 0 | 7 |
| 2017 | 0 | — | 0 | 4 |
| 2018 | 0 | — | 1 | 12 |
| 2019 | 0 | — | 2 | 9 |
| 2020 | 0 | — | 0 | 5 |
| 2021 | 0 | — | 0 | 4 |
| 2022 | 0 | — | 0 | 4 |
| 2023 | 0 | — | 0 | 8 |
| 2024 | 1 | — | 0 | 16 |
| 2025 | 0 | — | 0 | 53 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
A wearable sound-amplifying device that is intended to help cmpensate for impaired hearing. Sounds are electronically amplified and transmitted to the ear.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K972998 · printed Nov 4, 2026
Cite this page
510(k) Report. “K972998: Prisma.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K972998
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026