510(k) Report

510(k) · Cleared

Cleared

The Visualized Endotracheal Tube System or Vett System

K973191510(k) TraditionalCleared Feb 13, 1998172-day reviewClass II21 CFR 868.5730

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Pulmonx · BTR Tube, Tracheal (W/Wo Connector)

Cleared on Feb 13, 1998 after a 172-day review. The FDA summary names its predicate without a number. 1 of the 18 devices in its family, counting itself, has a Class I recall. 17 later devices descend from it.

Decided
Feb 13, 1998
Review
172 days
Class
Class II
Product code
BTR
Recalls
None
Predicates
0

17 later devices descend from it, 1 citing it directly. 1 of the 18 devices in this family, counting this one, has a Class I recall.

Descendants, by year cleared 2005: 1 descendant cleared2010: 2 descendants cleared2008: 1 descendant cleared2009: 2 descendants cleared2012: 2 descendants cleared2016: 2 descendants cleared2013: 1 descendant cleared2018: 2 descendants cleared2020: 1 descendant cleared, 1 with a Class I recall12025: 1 descendant cleared2021: 1 descendant cleared2024: 1 descendant cleared1995200020052010201520202025
  1. This deviceK973191 The Visualized Endotracheal Tube System or Vett SystemPulmonx · 1998
  2. Descendant · cites it directly · 16 of its ownK052233 Tracheoscopic Ventilation Tube (TVT) SystemEtview, Ltd. · 2005
  3. Descendant · 2 generations on · 14 of its ownK082420 Tracheoscopic Ventilation Tube (TVT)Etview · 2008
  4. Descendant · 3 generations on · 4 of its ownK113576 Double Lumen Video Tracheosdope (DLVT) SystemEtview, Ltd. · 2012
  5. Descendant · 4 generations on · 3 of its ownK123853 Vivasight-DL SystemEtview, Ltd. · 2013
  6. Descendant · 3 generations on · 3 of its ownK121028 Etview Tracheoscopic Ventilation Tube (TVT (TM))Etview, Ltd. · 2012

Showing 5 of 17 descendants. See all descendants

Descendants cleared per year

2005: 12008: 12009: 22010: 22012: 22013: 12016: 22018: 22020: 12021: 12024: 12025: 1
2005high 2 (2009) · low 0 (2006)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 17 · See all
  • K052233Tracheoscopic Ventilation Tube (TVT) SystemEtview, Ltd. · 2005 · cites it directly16descendants
  • K082420Tracheoscopic Ventilation Tube (TVT)Etview · 2008 · 2 generations on14descendants
  • K113576Double Lumen Video Tracheosdope (DLVT) SystemEtview, Ltd. · 2012 · 3 generations on4descendants
  • K123853Vivasight-DL SystemEtview, Ltd. · 2013 · 4 generations on3descendants
  • K121028Etview Tracheoscopic Ventilation Tube (TVT (TM))Etview, Ltd. · 2012 · 3 generations on3descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K973191The Visualized Endotracheal Tube System or Vett SystemPulmonx1998—
+1K052233Tracheoscopic Ventilation Tube (TVT) SystemEtview, Ltd.2005—
+2K082420Tracheoscopic Ventilation Tube (TVT)Etview2008—
+3K113576Double Lumen Video Tracheosdope (DLVT) SystemEtview, Ltd.2012—
+4K123853Vivasight-DL SystemEtview, Ltd.2013—
+3K121028Etview Tracheoscopic Ventilation Tube (TVT (TM))Etview, Ltd.2012—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200510
200810
200920
201020
201220
201310
201620
201820
202011
202110
202410
202510
FIG. 1 — Lineage of K973191, 1998–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new BTR device

  1. #1 K251794 Tenax® Laser Resistant Endotracheal Tubescore 12.6 · 3 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (5)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—Mallinckrodt Hi-Lo Tracheal Tube with Cuff
Named without a submission number
—
*—Olympus LF1/LF2 Tracheal Intubation Fiberscope
Named without a submission number
—
*—A.O. LS6A/LS7 Fiberoptic Laryngoscope
Named without a submission number
—
*—Welch Allyn Hi-Lux HLS-24W Illuminator
Named without a submission number
—
*—UroHealth Integrated Visualization System, END-101
Named without a submission number
—

What descends from it? (17)

See all 17

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K052233Tracheoscopic Ventilation Tube (TVT) SystemEtview, Ltd.200516

Has anything in its family been recalled? (1 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K193058SonarMed AirWave Airway Monitoring SystemSonarmed, Inc. · 2020 · 5 generations on · ◆ in the 2020 descendants bar of FIG. 14 Class I recalls

What does this lineage say?

  • Of its descendants, K052233 (Etview, Ltd., 2005) has gone furthest, with 16 descendants of its own.

How does its category compare?

All BTR devices

BTR Tube, Tracheal (W/Wo Connector): FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · BTR

7in 2025

2007: 12008: 72009: 72010: 32011: 22012: 52013: 12014: 32015: 32016: 12017: 22018: 52019: 52020: 32021: 12022: 12023: 12024: 12025: 72026 (partial year): 2
2007high 7 (2008) · low 1 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · BTR

258in 2025

2008: 61 days median2009: 135 days median2010: 179 days median2012: 261 days median2014: 308 days median2015: 262 days median2018: 242 days median2019: 211 days median2020: 246 days median2025: 258 days median
2007high 308 (2014) · low 61 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · BTR

3in 2022

2007: 22009: 212014: 20, 19 Class I2016: 12020: 1, 1 Class I2021: 22022: 32026 (partial year): 1
2007high 21 (2009) · low 0 (2008)2026

Class I (20 since 2007) Class II/III not classified

Adverse event reports per year · BTR

1,799in 2025

2007: 1362008: 1692009: 1552010: 3352011: 4222012: 5112013: 8072014: 9852015: 1,0162016: 8362017: 8122018: 9772019: 1,3792020: 1,0702021: 1,3292022: 1,1322023: 1,3302024: 1,6782025: 1,799
2007high 1,799 (2025) · low 136 (2007)2025

MAUDE reports naming product code BTR, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—2136
20087610169
2009713521155
201031790335
20112—0422
201252610511
20131—0807
2014330820 (19)985
2015326201,016
20161—1836
20172—0812
201852420977
2019521101,379
202032461 (1)1,070
20211—21,329
20221—31,132
20231—01,330
20241—01,678
2025725801,799
20262—1—

What is it indicated for?

The Pulmonx Visualized Endotracheal Tube (VETT) is indicated for use as a temporary artificial airway in adults requiring mechanical ventilation, for oral and nasal intubations.

The VETT System is indicated for viewing during difficult intubation procedures, for verifying tube placement and repositioning, for viewing during suctioning and for general inspection of the airway.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K973191: The Visualized Endotracheal Tube System or Vett System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K973191

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026