510(k) Report

510(k) · Cleared

Recalled · Class II · 2024

Clearview Blower/Mister

K973485510(k) TraditionalCleared Dec 8, 199784-day reviewClass II21 CFR 880.5475Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Dlp, Inc. · FQH Lavage, Jet

Cleared on Dec 8, 1997 as substantially equivalent to K922083 (Research Medical, Inc., 1993) after an 84-day review. Its family tree reaches back 1 generation to 1993. It has been recalled once.

Decided
Dec 8, 1997
Review
84 days
Class
Class II
Product code
FQH
Recalls
1
Predicates
1

Its longest line of descent runs back 1 generation to K922083 (1993). No later device cites it as a predicate yet.

K922083 · Rmi Surgiccal Site Visualization Wand · Research Medical, Inc. · 199319901992199419961998
  1. Root · 1 generation backK922083 Rmi Surgiccal Site Visualization WandResearch Medical, Inc. · 1993
  2. This deviceK973485 Clearview Blower/MisterDlp, Inc. · 1997
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K922083Rmi Surgiccal Site Visualization WandResearch Medical, Inc.1993—
0 (this device)K973485Clearview Blower/MisterDlp, Inc.1997—
FIG. 1 — Lineage of K973485, 1993–1997Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FQH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FQH device

  1. #1 K253996 BD Surgiphor™ Antimicrobial Irrigation System…score 14.8 · 14 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K922083Rmi Surgiccal Site Visualization Wand
Summary page 1
…475 LEGALLY MARKETED PREDICATE DEVICE The claim of substantial equivalence of the ClearView Blower/Mister is made to the RMI VisuFlow Surgical Site Visualization Wand, K922083. DEVICE DESCRIPTION The ClearView Blower/Mister includes a hand grip with a 3 1/4” or 6 1/2” malleable stainless steel shaft fo…
Research Medical, Inc.1993—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Mar 19, 2024Class IIZ-1794-2024Process controlPotential for unsealed sterile packing.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.

How does its category compare?

All FQH devices

FQH Lavage, Jet: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · FQH

3in 2023

2007: 12009: 32011: 22012: 12015: 12016: 12020: 32021: 12022: 42023: 32026 (partial year): 2
2007high 4 (2022) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FQH

410in 2023

2009: 240 days median2020: 130 days median2022: 136 days median2023: 410 days median
2007high 410 (2023) · low 130 (2020)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FQH

2in 2019

2007: 132009: 12010: 72017: 12019: 2
2007high 13 (2007) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FQH

835in 2025

2007: 102008: 272009: 702010: 1352011: 832012: 1332013: 1342014: 1942015: 1162016: 1502017: 2432018: 3172019: 3282020: 3932021: 3982022: 1712023: 3332024: 4252025: 835
2007high 835 (2025) · low 10 (2007)2025

MAUDE reports naming product code FQH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—1310
20080—027
20093240170
20100—7135
20112—083
20121—0133
20130—0134
20140—0194
20151—0116
20161—0150
20170—1243
20180—0317
20190—2328
202031300393
20211—0398
202241360171
202334100333
20240—0425
20250—0835
20262—0—

What is it indicated for?

This device is intended for use during procedures when a wound or surgical site must be cleared by non-contact means for improved visibility at the site.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K973485: Clearview Blower/Mister.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K973485

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026