510(k) · Cleared
ClearedVacuette Multi-Sample Needle
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Greiner Meditech, Inc. · FMI Needle, Hypodermic, Single Lumen
Cleared on Dec 17, 1997 as substantially equivalent to K950159 (Gainor Medical U.S.A., Inc., 1995) after an 85-day review. Its family tree reaches back 1 generation to 1995. 7 later devices descend from it.
- Decided
- Dec 17, 1997
- Review
- 85 days
- Class
- Class II
- Product code
- FMI
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 1 generation to K950159 (1995). 7 later devices descend from it, 3 citing it directly.
- Root · 1 generation backK950159 SuresharpGainor Medical U.S.A., Inc. · 1995
- This deviceK973620 Vacuette Multi-Sample NeedleGreiner Meditech, Inc. · 1997
- Descendant · cites it directly · 5 of its ownK061483 Vacuette Visio Plus Blood Collection NeedlesGreiner Bio-One North America, Inc. · 2006
- Descendant · 2 generations on · 1 of its ownK073127 Blood Collection Needle, Model 20G 21G 22GShandong Weigao Group Medical Polymer Co., Ltd. · 2007
- Descendant · cites it directly · 1 of its ownK072320 Greiner Vacuette Quickshield CompleteGreiner Bio-One North America, Inc. · 2007 · Recalled
- Descendant · 2 generations on · 0 of its ownK233979 VACUETTE® QUICKSHIELD Complete (Plus)Greiner Bio-One North America, Inc. · 2024
- Descendant · 2 generations on · 0 of its ownK110656 Imc Blood Collection NeedleInternational Medsurg Connection · 2011
Showing 5 of 7 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 7 · See all- K061483Vacuette Visio Plus Blood Collection NeedlesGreiner Bio-One North America, Inc. · 2006 · cites it directly5descendants
- K073127Blood Collection Needle, Model 20G 21G 22GShandong Weigao Group Medical Polymer Co., Ltd. · 2007 · 2 generations on1descendant
- K072320Greiner Vacuette Quickshield CompleteGreiner Bio-One North America, Inc. · 2007 · cites it directly1descendant
- K233979VACUETTE® QUICKSHIELD Complete (Plus)Greiner Bio-One North America, Inc. · 2024 · 2 generations on0descendants
- K110656Imc Blood Collection NeedleInternational Medsurg Connection · 2011 · 2 generations on0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K950159 | Suresharp | Gainor Medical U.S.A., Inc. | 1995 | — |
| 0 (this device) | K973620 | Vacuette Multi-Sample Needle | Greiner Meditech, Inc. | 1997 | — |
| +1 | K061483 | Vacuette Visio Plus Blood Collection Needles | Greiner Bio-One North America, Inc. | 2006 | — |
| +2 | K073127 | Blood Collection Needle, Model 20G 21G 22G | Shandong Weigao Group Medical Polymer Co., Ltd. | 2007 | — |
| +1 | K072320 | Greiner Vacuette Quickshield Complete | Greiner Bio-One North America, Inc. | 2007 | 1 |
| +2 | K233979 | VACUETTE® QUICKSHIELD Complete (Plus) | Greiner Bio-One North America, Inc. | 2024 | — |
| +2 | K110656 | Imc Blood Collection Needle | International Medsurg Connection | 2011 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2006 | 1 | 0 |
| 2007 | 3 | 0 |
| 2011 | 2 | 0 |
| 2024 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in FMI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new FMI device
- #1 K252886 Pen Needlescore 14.5 · 4 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K950159 | SuresharpSummary page 1…holder which is used to guide the needle into an evacuated blood collection tube.. Greiner is claiming substantial equivalence to Gainor Medical’s Suresharp” needles (K950159). Both multi-sample needles have the same intended use and contain the same material. The material of the Greiner needle is stain… | 1995 |
What descends from it? (7)
3 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
How does its category compare?
All FMI devicesFMI Needle, Hypodermic, Single Lumen: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · FMI
11in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · FMI
141in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · FMI
1in 2024
Class I (1 since 2007) Class II/III not classified
Adverse event reports per year · FMI
2,424in 2025
MAUDE reports naming product code FMI, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 15 | 71 | 2 | 208 |
| 2008 | 10 | 85 | 4 | 177 |
| 2009 | 7 | 177 | 3 | 263 |
| 2010 | 15 | 119 | 79 | 249 |
| 2011 | 12 | 113 | 5 | 240 |
| 2012 | 17 | 107 | 1 | 215 |
| 2013 | 11 | 87 | 1 | 255 |
| 2014 | 14 | 155 | 3 | 287 |
| 2015 | 10 | 89 | 1 | 567 |
| 2016 | 20 | 217 | 0 | 941 |
| 2017 | 9 | 253 | 16 | 1,547 |
| 2018 | 20 | 176 | 0 | 2,398 |
| 2019 | 12 | 186 | 5 | 4,896 |
| 2020 | 11 | 263 | 3 | 4,245 |
| 2021 | 18 | 143 | 7 | 4,532 |
| 2022 | 23 | 189 | 0 | 4,885 |
| 2023 | 18 | 112 | 2 | 4,986 |
| 2024 | 3 | 90 | 1 | 4,053 |
| 2025 | 11 | 141 | 0 | 2,424 |
| 2026 | 12 | 119 | 1 (1) | — |
What is it indicated for?
For use in venous blood collection
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K973620 · printed Nov 4, 2026
Cite this page
510(k) Report. “K973620: Vacuette Multi-Sample Needle.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K973620
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026