510(k) Report

510(k) · Cleared

Cleared

Bioscrew Absorbable Interference Srew

K973758510(k) TraditionalCleared Feb 27, 1998148-day reviewClass II21 CFR 888.3040

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Linvatec Corp. · HWC Screw, Fixation, Bone

Cleared on Feb 27, 1998 after a 148-day review. The FDA summary names its predicate without a number. 416 later devices descend from it.

Decided
Feb 27, 1998
Review
148 days
Class
Class II
Product code
HWC
Recalls
None
Predicates
0

416 later devices descend from it, 10 citing it directly.

Descendants, by year cleared 2002: 3 descendants cleared2005: 6 descendants cleared1999: 2 descendants cleared2000: 1 descendant cleared2007: 4 descendants cleared2004: 3 descendants cleared2009: 13 descendants cleared2006: 3 descendants cleared2010: 5 descendants cleared2008: 7 descendants cleared2003: 1 descendant cleared2022: 28 descendants cleared2012: 8 descendants cleared2011: 10 descendants cleared2013: 12 descendants cleared2014: 21 descendants cleared2018: 19 descendants cleared2019: 32 descendants cleared2017: 23 descendants cleared2020: 27 descendants cleared2024: 37 descendants cleared2025: 38 descendants cleared2015: 11 descendants cleared2021: 24 descendants cleared2026: 36 descendants cleared2016: 8 descendants cleared2023: 34 descendants cleared1995200020052010201520202025
  1. This deviceK973758 Bioscrew Absorbable Interference SrewLinvatec Corp. · 1998
  2. Descendant · cites it directly · 310 of its ownK990194 BiobuttonLinvatec Corp. · 1999
  3. Descendant · 2 generations on · 309 of its ownK033717 Transet Fracture Fixation SystemBonutti Research, Inc. · 2004
  4. Descendant · 3 generations on · 306 of its ownK043248 Tightrope Syndesmosis Repair Kit, Titanium, Model AR-8920DS…Arthrex, Inc. · 2005
  5. Descendant · 4 generations on · 217 of its ownK052776 Tightrope Acromioclavicular (AC) Device, Titanium, Stainless Steel…Arthrex, Inc. · 2005
  6. Descendant · 4 generations on · 94 of its ownK083070 Toggleloc SystemBiomet Sports Medicine · 2008 · Recalled

Showing 5 of 416 descendants. See all descendants

Descendants cleared per year

1999: 22000: 12002: 32003: 12004: 32005: 62006: 32007: 42008: 72009: 132010: 52011: 102012: 82013: 122014: 212015: 112016: 82017: 232018: 192019: 322020: 272021: 242022: 282023: 342024: 372025: 382026: 36
1999high 38 (2025) · low 0 (2001)2026

Most influential descendants

Showing 5 of 416 · See all
  • K990194BiobuttonLinvatec Corp. · 1999 · cites it directly310descendants
  • K033717Transet Fracture Fixation SystemBonutti Research, Inc. · 2004 · 2 generations on309descendants
  • K043248Tightrope Syndesmosis Repair Kit, Titanium, Model AR-8920DS; Stainless Steel. Model…Arthrex, Inc. · 2005 · 3 generations on306descendants
  • K052776Tightrope Acromioclavicular (AC) Device, Titanium, Stainless Steel , Models AR-2257…Arthrex, Inc. · 2005 · 4 generations on217descendants
  • K083070Toggleloc SystemBiomet Sports Medicine · 2008 · 4 generations on94descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K973758Bioscrew Absorbable Interference SrewLinvatec Corp.1998—
+1K990194BiobuttonLinvatec Corp.1999—
+2K033717Transet Fracture Fixation SystemBonutti Research, Inc.2004—
+3K043248Tightrope Syndesmosis Repair Kit, Titanium, Model AR-8920DS; Stainless Steel.…Arthrex, Inc.2005—
+4K052776Tightrope Acromioclavicular (AC) Device, Titanium, Stainless Steel , Models…Arthrex, Inc.2005—
+4K083070Toggleloc SystemBiomet Sports Medicine20086

Descendants by year cleared

Year clearedDevicesWith a Class I recall
199920
200010
200230
200310
200430
200560
200630
200740
200870
2009130
201050
2011100
201280
2013120
2014210
2015110
201680
2017230
2018190
2019320
2020270
2021240
2022280
2023340
2024370
2025380
2026360
FIG. 1 — Lineage of K973758, 1998–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HWC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new HWC device

  1. #1 K203011 Monster Screw Systemscore 22.2 · 14 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—Linvatec BioScrew Absorbable Interference Screw
Named without a submission number
—
*—Arthrex Interference Screws
Named without a submission number
—
*—Arthrotek Interference Screw
Named without a submission number
—

What descends from it? (416)

See all 416

10 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K990194BiobuttonLinvatec Corp.1999310
K013131Bioscrew XtralokLinvatec Corp.200277
K993073Smart Screw Acl Models 237020, 237025, 237030, 238020, 238025, 238030, 239020, 239025…Bionx Implants, Ltd.199916
K032894Osteo Acl Screw Model;237020T, 237025T, 237030T, 238020T, 238025T, 238030T, 239020T…Linvatec Biomaterials, Inc.200415
K051611Mbaresorb ImplantKinetikos Medical, Inc.200510
K063588Matryx Interference Screw, 239038T5,231025T5,231033T5,231038T5,231125T5,231133T5,231138T5Conmed Linvatec Biomaterials20073
K013781Rididfix 2.7MM BTB Cross Pin KitMitek Products20023
K021280Inion Hexalon Biodegradable Acl/PCL ScrewInion, Ltd.20021
K993166Stryker Bioabsorbable Interference Screw SystemStryker Endoscopy20001
K031939Bio-Eurolig Interference ScrewFournitures Hospitalieres Industrie20040

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K990194 (Linvatec Corp., 1999) has gone furthest, with 310 descendants of its own.

How does its category compare?

All HWC devices

HWC Screw, Fixation, Bone: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · HWC

15in 2025

2007: 352008: 332009: 272010: 232011: 352012: 202013: 252014: 312015: 412016: 262017: 402018: 202019: 302020: 282021: 262022: 262023: 242024: 172025: 152026 (partial year): 21
2007high 41 (2015) · low 15 (2025)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HWC

111in 2025

2007: 77 days median2008: 76 days median2009: 113 days median2010: 110 days median2011: 88 days median2012: 99 days median2013: 90 days median2014: 88 days median2015: 85 days median2016: 131 days median2017: 127 days median2018: 106 days median2019: 108 days median2020: 75 days median2021: 84 days median2022: 167 days median2023: 104 days median2024: 90 days median2025: 111 days median2026 (partial year): 125 days median
2007high 167 (2022) · low 75 (2020)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · HWC

1in 2025

2007: 252008: 332009: 292010: 72011: 122012: 302013: 142014: 22015: 52016: 42017: 42018: 12019: 52020: 42021: 22022: 132025: 12026 (partial year): 2
2007high 33 (2008) · low 0 (2023)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · HWC

2,893in 2025

2007: 6692008: 6602009: 6512010: 7652011: 1,1042012: 3,3392013: 3,8502014: 2,5492015: 2,7112016: 2,2852017: 2,5612018: 3,6622019: 5,4632020: 4,8202021: 4,4462022: 3,9342023: 3,7182024: 3,5752025: 2,893
2007high 5,463 (2019) · low 651 (2009)2025

MAUDE reports naming product code HWC, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007357725669
2008337633660
20092711329651
2010231107765
20113588121,104
20122099303,339
20132590143,850
2014318822,549
2015418552,711
20162613142,285
20174012742,561
20182010613,662
20193010855,463
2020287544,820
2021268424,446
202226167133,934
20232410403,718
2024179003,575
20251511112,893
2026211252—

What is it indicated for?

1. The BioScrew is used to provide interference fixation of patellar bone-tendon-bone grafts in anterior cruciate ligament reconstruction.

2. The BioScrew is used to provide interference fixation during femoral and/or tibial fixation in anterior cruciate ligament reconstruction using a soft tissue graft (semitendinosus, gracilis).

3. The BioScrew is used to provide interference fixation during posterior cruciate ligament reconstruction.

Implantation of the interference screw is accomplished through arthroscopy or arthrotomy. This device is a single-use device.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K973758: Bioscrew Absorbable Interference Srew.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K973758

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026