510(k) Report

510(k) · Cleared

Cleared

Sphincterotome

K973826510(k) TraditionalCleared Dec 5, 199759-day reviewClass II21 CFR 876.4300

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Boston Scientific Corp · KNS Unit, Electrosurgical, Endoscopic (With Or Without Accessories)

Cleared on Dec 5, 1997 after a 59-day review. The FDA summary names its predicate without a number. 1 later device descends from it.

Decided
Dec 5, 1997
Review
59 days
Class
Class II
Product code
KNS
Recalls
None
Predicates
0

1 later device descends from it, 1 citing it directly.

Descendants, by year cleared 2006: 1 descendant cleared1995200020052010201520202025
  1. This deviceK973826 SphincterotomeBoston Scientific Corp · 1997
  2. Descendant · cites it directly · 0 of its ownK061684 Medi-Globe Rota-Cut SphincterotomeMedi-Globe Corporation · 2006

Most influential descendants

Showing 1 of 1 · See all
  • K061684Medi-Globe Rota-Cut SphincterotomeMedi-Globe Corporation · 2006 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K973826SphincterotomeBoston Scientific Corp1997—
+1K061684Medi-Globe Rota-Cut SphincterotomeMedi-Globe Corporation2006—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200610
FIG. 1 — Lineage of K973826, 1997–2006Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KNS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KNS device

  1. #1 K241271 Aqua Medical RF Vapor Ablation Systemscore 17.2 · 20 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—Microvasive® Rapid Exchange Sphincterotome
Named without a submission number
—
*—Ultratome XL™ Triple Lumen Sphincterotome
Named without a submission number
—

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K061684Medi-Globe Rota-Cut SphincterotomeMedi-Globe Corporation20060

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K061684 (Medi-Globe Corporation, 2006) has gone furthest, with 0 descendants of its own.

How does its category compare?

All KNS devices

KNS Unit, Electrosurgical, Endoscopic (With Or Without Accessories): FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · KNS

11in 2025

2007: 12008: 32009: 32010: 42011: 12012: 22013: 22014: 12015: 32016: 32017: 32018: 52019: 72020: 42021: 42022: 32023: 92024: 32025: 112026 (partial year): 2
2007high 11 (2025) · low 1 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KNS

171in 2025

2008: 61 days median2009: 212 days median2010: 168 days median2015: 252 days median2016: 30 days median2017: 48 days median2018: 62 days median2019: 66 days median2020: 212 days median2021: 139 days median2022: 182 days median2023: 83 days median2024: 198 days median2025: 171 days median
2007high 252 (2015) · low 30 (2016)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KNS

14in 2024

2007: 32008: 52009: 22011: 22016: 62017: 12021: 412024: 142026 (partial year): 4
2007high 41 (2021) · low 0 (2010)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · KNS

1,504in 2025

2007: 1642008: 5872009: 1,0272010: 9082011: 8602012: 8482013: 4492014: 4052015: 4062016: 4572017: 4462018: 5632019: 6682020: 9062021: 8142022: 9132023: 9762024: 1,5332025: 1,504
2007high 1,533 (2024) · low 164 (2007)2025

MAUDE reports naming product code KNS, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—3164
20083615587
2009321221,027
201041680908
20111—2860
20122—0848
20132—0449
20141—0405
201532520406
20163306457
20173481446
20185620563
20197660668
202042120906
2021413941814
202231820913
20239830976
20243198141,533
20251117101,504
20262—4—

What is it indicated for?

The Microvasive® Needle Knife Sphincterotome is indicated for use in transendoscopic sphincterotomy of the Papilla of Vater and/or the Sphincter of Oddi. The Microvasive Needle Knife can also be used to cannulate and inject contrast medium.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K973826: Sphincterotome.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K973826

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026