510(k) · Cleared
ClearedBranemark System Dec 600 Drilling Unit
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Nobel Biocare Uas, Inc. · DZE Implant, Endosseous, Root-Form
Cleared on May 26, 1998 as substantially equivalent to K905436 (Nobelpharma USA, Inc., 1991) after a 204-day review. Its family tree reaches back 1 generation to 1991.
- Decided
- May 26, 1998
- Review
- 204 days
- Class
- Class II
- Product code
- DZE
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 1 generation to K905436 (1991). No later device cites it as a predicate yet.
- Root · 1 generation backK905436 Nobelpharma Drilling Equipment Dec 500Nobelpharma USA, Inc. · 1991
- This deviceK974123 Branemark System Dec 600 Drilling UnitNobel Biocare Uas, Inc. · 1998
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K905436 | Nobelpharma Drilling Equipment Dec 500 | Nobelpharma USA, Inc. | 1991 | — |
| 0 (this device) | K974123 | Branemark System Dec 600 Drilling Unit | Nobel Biocare Uas, Inc. | 1998 | — |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DZE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DZE device
- #1 K211090 ZENEX Implant Systemscore 25.4 · 15 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K905436 | Nobelpharma Drilling Equipment Dec 500Summary page 1…Predicate Product The predicate product used in this Premarket Notification is the Branemark System® Drill Equipment DEC 500 handpiece subject to premarket Notification K905436. D. Description of the Device The Nobel Biocare Branemark System® DEC 600 Drilling Unit is intended for use in oral and maxillo… | 1991 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Its one ancestor has no recall.
How does its category compare?
All DZE devicesDZE Implant, Endosseous, Root-Form: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · DZE
31in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DZE
184in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DZE
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · DZE
465,788in 2025
MAUDE reports naming product code DZE, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 43 | 107 | 11 | 225 |
| 2008 | 61 | 118 | 4 | 393 |
| 2009 | 41 | 110 | 3 | 164 |
| 2010 | 34 | 162 | 3 | 360 |
| 2011 | 26 | 194 | 0 | 362 |
| 2012 | 39 | 174 | 11 | 358 |
| 2013 | 42 | 195 | 1 | 391 |
| 2014 | 36 | 265 | 7 | 1,124 |
| 2015 | 36 | 215 | 3 | 2,894 |
| 2016 | 40 | 219 | 15 | 1,116 |
| 2017 | 48 | 223 | 4 | 9,719 |
| 2018 | 41 | 200 | 4 | 12,892 |
| 2019 | 31 | 231 | 8 | 167,016 |
| 2020 | 41 | 230 | 0 | 255,524 |
| 2021 | 34 | 182 | 6 | 479,618 |
| 2022 | 34 | 243 | 0 | 483,224 |
| 2023 | 35 | 248 | 0 | 537,585 |
| 2024 | 40 | 222 | 1 | 473,629 |
| 2025 | 31 | 184 | 1 | 465,788 |
| 2026 | 15 | 194 | 2 | — |
What is it indicated for?
The Nobel Biocare’s Branemark System® DEC 600 Drilling Unit is intended to be used in oral and maxillo facial surgery including placement of the Branemark System endosseous implants. It is intended to be used to drill into the upper or lower jaw to prepare placement of an endosseous fixture, in the treading and mounting of fixtures, while drilling measure and record torque resistance for bone quality, as well as to tighten cover and abutment screws.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K974123 · printed Nov 6, 2026
Cite this page
510(k) Report. “K974123: Branemark System Dec 600 Drilling Unit.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K974123
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026