510(k) Report

510(k) · Cleared

Cleared

Karl Storz Endovision XL Endoscopic Camera System

K974391510(k) TraditionalCleared Jan 30, 199870-day reviewClass II21 CFR 876.1500

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Karl Storz Imaging, Inc. · GCJ Laparoscope, General & Plastic Surgery

Cleared on Jan 30, 1998 as substantially equivalent to K950862 (Karl Storz Imaging, Inc., 1995) and 1 other predicate after a 70-day review. Its family tree reaches back 1 generation to 1988. 4 later devices descend from it.

Decided
Jan 30, 1998
Review
70 days
Class
Class II
Product code
GCJ
Recalls
None
Predicates
2

Its longest line of descent runs back 1 generation to K883943 (1988). 2 ancestors in all. 4 later devices descend from it, 3 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1995: 1 other ancestor2008: 1 descendant cleared1999: 1 descendant cleared2002: 1 descendant cleared2003: 1 descendant clearedK883943 · CCM-1 Video Camera System · Medical Concepts, Inc. · 19881990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor 1 generation forward: 3 descendants2 generations forward: 1 descendant K883943 · CCM-1 Video Camera System · Medical Concepts, Inc. · 19880
  1. Root · 1 generation backK883943 CCM-1 Video Camera SystemMedical Concepts, Inc. · 1988
  2. This deviceK974391 Karl Storz Endovision XL Endoscopic Camera SystemKarl Storz Imaging, Inc. · 1998
  3. Descendant · cites it directly · 1 of its ownK020336 Endoscopic Camera MC404/C3World of Medicine Lemke GmbH · 2002
  4. Descendant · cites it directly · 0 of its ownK080809 Iec Medsight and MedbrightInnovative Endoscopy Components, LLC · 2008
  5. Descendant · 2 generations on · 0 of its ownK032544 VP-1000; Med Cam 100; VP-3000A; Med Cam 300Mgb Endoskopische Gerate GmbH (Berlin) · 2003
  6. Descendant · cites it directly · 0 of its ownK991416 Endoscopic CameraGenzyme Surgical Product (Genzyme Biosurgery) · 1999

Most influential descendants

Showing 4 of 4 · See all
  • K020336Endoscopic Camera MC404/C3World of Medicine Lemke GmbH · 2002 · cites it directly1descendant
  • K080809Iec Medsight and MedbrightInnovative Endoscopy Components, LLC · 2008 · cites it directly0descendants
  • K032544VP-1000; Med Cam 100; VP-3000A; Med Cam 300Mgb Endoskopische Gerate GmbH (Berlin) · 2003 · 2 generations on0descendants
  • K991416Endoscopic CameraGenzyme Surgical Product (Genzyme Biosurgery) · 1999 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K883943CCM-1 Video Camera SystemMedical Concepts, Inc.1988—
0 (this device)K974391Karl Storz Endovision XL Endoscopic Camera SystemKarl Storz Imaging, Inc.1998—
+1K020336Endoscopic Camera MC404/C3World of Medicine Lemke GmbH2002—
+1K080809Iec Medsight and MedbrightInnovative Endoscopy Components, LLC2008—
+2K032544VP-1000; Med Cam 100; VP-3000A; Med Cam 300Mgb Endoskopische Gerate GmbH (Berlin)2003—
+1K991416Endoscopic CameraGenzyme Surgical Product (Genzyme Biosurgery)1999—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199510

Descendants by year cleared

Year clearedDevicesWith a Class I recall
199910
200210
200310
200810
FIG. 1 — Lineage of K974391, 1988–2008Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GCJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GCJ device

  1. #1 K214046 780 nm 1688 4K Camera System, 780 nm L11 LED…score 21.4 · 21 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K950862Karl Storz Endovision Tricam, Model 20221101 (20221001, Pal Format) Color Television…
Summary page 2
…on XL endoscopic camera system, is substantially equivalent to several other systems currently on the market including the KSI Tricam Color Endoscogic Television System (K950862) and the KSI Telecam Color Endoscopic Television System (K883943). The proposed new KSI Endovision XL is unique only in thatitisa…
Karl Storz Imaging, Inc.1995—
*K883943CCM-1 Video Camera System
Summary page 2
…veral other systems currently on the market including the KSI Tricam Color Endoscogic Television System (K950862) and the KSI Telecam Color Endoscopic Television System (K883943). The proposed new KSI Endovision XL is unique only in thatitisa smaller, lighter, more portable camera system. Signed: _\ a‘mfi/…
Medical Concepts, Inc.1988—

Also cleared against K950862: 5 other devices →

What descends from it? (4)

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K020336Endoscopic Camera MC404/C3World of Medicine Lemke GmbH20021
K080809Iec Medsight and MedbrightInnovative Endoscopy Components, LLC20080
K991416Endoscopic CameraGenzyme Surgical Product (Genzyme Biosurgery)19990

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • None of the 2 ancestors has a recall.
  • Of its descendants, K020336 (World of Medicine Lemke GmbH, 2002) has gone furthest, with 1 descendant of its own.
  • 5 other devices also cite its predicate K950862.

How does its category compare?

All GCJ devices

GCJ Laparoscope, General & Plastic Surgery: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · GCJ

21in 2025

2007: 182008: 192009: 212010: 242011: 152012: 172013: 152014: 192015: 262016: 272017: 202018: 212019: 152020: 282021: 182022: 202023: 312024: 292025: 212026 (partial year): 26
2007high 31 (2023) · low 15 (2011)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GCJ

108in 2025

2007: 42 days median2008: 73 days median2009: 85 days median2010: 122 days median2011: 113 days median2012: 88 days median2013: 93 days median2014: 90 days median2015: 76 days median2016: 99 days median2017: 77 days median2018: 88 days median2019: 60 days median2020: 61 days median2021: 116 days median2022: 103 days median2023: 109 days median2024: 90 days median2025: 108 days median2026 (partial year): 122 days median
2007high 122 (2010) · low 42 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GCJ

5in 2025

2007: 122008: 162009: 62010: 302011: 92012: 12013: 7, 1 Class I2014: 22016: 52017: 12018: 12022: 12023: 12025: 52026 (partial year): 1
2007high 30 (2010) · low 0 (2015)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · GCJ

5,860in 2025

2007: 1,6392008: 1,3192009: 1,9952010: 2,6572011: 2,1332012: 1,5262013: 1,5652014: 1,7142015: 1,7102016: 2,0802017: 3,4682018: 2,5622019: 2,5782020: 2,6182021: 3,4312022: 3,9452023: 6,0022024: 6,0472025: 5,860
2007high 6,047 (2024) · low 1,319 (2008)2025

MAUDE reports naming product code GCJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071842121,639
20081973161,319
2009218561,995
201024122302,657
20111511392,133
2012178811,526
201315937 (1)1,565
2014199021,714
2015267601,710
2016279952,080
2017207713,468
2018218812,562
2019156002,578
2020286102,618
20211811603,431
20222010313,945
20233110916,002
2024299006,047
20252110855,860
2026261221—

What is it indicated for?

The Karl Storz Imaging (KSI) Endovision XL Camera System is a color, television camera system designed for attachment to endoscopic visioning systems.

The camera head is suitable for atachment to any rigid or flexible endoscope, including, such as sinoscopes, colonoscopes, sigmoidoscopes, bronchoscopes, gastroscopes, laparoscopes, choledoscopes, nreteroscopes, hysteroscopes and arthroscopes. The camera head is coupled to the endoscope with a V-mount adapter. The camera is connected to the video processor via cable. The endoscopic image can be displayed on any standard operating room video monitor.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K974391: Karl Storz Endovision XL Endoscopic Camera System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K974391

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026