Aeroset System

K980367510(k) TraditionalCleared Apr 1, 199862-day reviewClass II21 CFR 862.1170Recalls 34

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Abbott Laboratories · CGZ Electrode, Ion-Specific, Chloride

Cleared on Apr 1, 1998 as substantially equivalent to K872494 (Boehringer Mannheim Corp., 1987) after a 62-day review. Its family tree reaches back 1 generation to 1987. 7 later devices descend from it. It has been recalled 34 times.

Decided
Apr 1, 1998
Review
62 days
Class
Class II
Product code
CGZ
Recalls
34
Predicates
1

Its longest line of descent runs back 1 generation to K872494 (1987). 7 later devices descend from it, 3 citing it directly.

Descendants, by year cleared 2010: 1 descendant cleared2017: 2 descendants cleared2012: 1 descendant cleared2022: 1 descendant cleared2023: 2 descendants clearedK872494 · Hitachi 717 Chemistry Analyzer · Boehringer Mannheim Corp. · 19871990200020102020
Descendants, by generation 1 generation forward: 3 descendants2 generations forward: 3 descendants3 generations forward: 1 descendant K872494 · Hitachi 717 Chemistry Analyzer · Boehringer Mannheim Corp. · 19870
  1. Root · 1 generation backK872494 Hitachi 717 Chemistry AnalyzerBoehringer Mannheim Corp. · 1987
  2. This deviceK980367 Aeroset SystemAbbott Laboratories · 1998
  3. Descendant · cites it directly · 3 of its ownK093318 Accelerator ApsAbbott Laboratories · 2010 · Recalled
  4. Descendant · 2 generations on · 1 of its ownK213486 GLP systems TrackAbbott Laboratories · 2022
  5. Descendant · cites it directly · 1 of its ownK170320 Alinity c ICT Sample DiluentAbbott Laboratories · 2017
  6. Descendant · cites it directly · 1 of its ownK170316 Alinity C Glucose Reagent Kit, Alinity C SystemAbbott Laboratories · 2017 · Recalled
  7. Descendant · 3 generations on · 0 of its ownK230937 Alinity i Total ß-hCG Reagent Kit, GLP systems TrackAbbott Laboratories · 2023

Showing 5 of 7 descendants. See all descendants

Descendants cleared per year

2010: 12012: 12017: 22022: 12023: 2
2010high 2 (2017) · low 0 (2011)2026

Most influential descendants

Showing 5 of 7 · See all
  • K093318Accelerator ApsAbbott Laboratories · 2010 · cites it directly3descendants
  • K213486GLP systems TrackAbbott Laboratories · 2022 · 2 generations on1descendant
  • K170320Alinity c ICT Sample DiluentAbbott Laboratories · 2017 · cites it directly1descendant
  • K170316Alinity C Glucose Reagent Kit, Alinity C SystemAbbott Laboratories · 2017 · cites it directly1descendant
  • K230937Alinity i Total ß-hCG Reagent Kit, GLP systems TrackAbbott Laboratories · 2023 · 3 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K872494Hitachi 717 Chemistry AnalyzerBoehringer Mannheim Corp.1987—
0 (this device)K980367Aeroset SystemAbbott Laboratories1998—
+1K093318Accelerator ApsAbbott Laboratories20102
+2K213486GLP systems TrackAbbott Laboratories2022—
+1K170320Alinity c ICT Sample DiluentAbbott Laboratories2017—
+1K170316Alinity C Glucose Reagent Kit, Alinity C SystemAbbott Laboratories20171
+3K230937Alinity i Total ß-hCG Reagent Kit, GLP systems TrackAbbott Laboratories2023—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201010
201210
201720
202210
202320
FIG. 1 — Lineage of K980367, 1987–2023Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in CGZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K872494Hitachi 717 Chemistry Analyzer
Summary page 3
…stantial Equivalence: Substantial equivalence has been demonstrated between the AEROSET System and the Boehringer Mannheim Diagnostics' Hitachi® 717 Chemistry Analyzer (K872494). Both systems utilize monochromatic and bichromatic spectrophotometry to perform quantitative kinetic and endpoint clinical che…
Boehringer Mannheim Corp.1987—

Also cleared against K872494: 4 other devices →

What descends from it? (7)

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K093318Accelerator ApsAbbott Laboratories20103
K170320Alinity c ICT Sample DiluentAbbott Laboratories20171
K170316Alinity C Glucose Reagent Kit, Alinity C SystemAbbott Laboratories20171

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
May 1, 2019Class IIZ-1671-2020Device DesignMixer blade may separate from mixer due to the screw and nut failure and detachment. As a result of the mixer blade missing, the sample and reagent are inadequately mixed.
Aug 28, 2018Class IIZ-1296-2019Under Investigation by firmThere is a potential to generate falsely elevated serum or plasma chloride results when using the product.
Jul 17, 2018Class IIZ-1102-2019Software designThere is a potential to generate incorrect results on the instrument if particular error codes are not resolved before transitioning to the Running status.
Jul 17, 2018Class IIZ-1104-2019Software designThere is a potential to generate incorrect results on the instrument if particular error codes are not resolved before transitioning to the Running status.
Jul 17, 2018Class IIZ-1103-2019Software designThere is a potential to generate incorrect results on the instrument if particular error codes are not resolved before transitioning to the Running status.
Dec 8, 2017Class IIZ-0922-2018Device DesignThere is a potential to generate falsely depressed patient results in the cuvettes adjacent to the detached segment post for any assay run on the c4000, c8000, and c16000 instrument.
Dec 8, 2017Class IIZ-0921-2018Device DesignThere is a potential to generate falsely depressed patient results in the cuvettes adjacent to the detached segment post for any assay run on the c4000, c8000, and c16000 instrument.
Dec 8, 2017Class IIZ-0923-2018Device DesignThere is a potential to generate falsely depressed patient results in the cuvettes adjacent to the detached segment post for any assay run on the c4000, c8000, and c16000 instrument.
Sep 29, 2017Class IIZ-0165-2018Component design/selectionThe Peristaltic Head tubing placed on the ARCHITECT c4000, c8000, and c16000 has the possibility to leak due to a manufacturing issue associated with the tubing connector.
Sep 29, 2017Class IIZ-0166-2018Component design/selectionThe Peristaltic Head tubing placed on the ARCHITECT c4000, c8000, and c16000 has the possibility to leak due to a manufacturing issue associated with the tubing connector.
Sep 9, 2015Class IIZ-0163-2016Nonconforming Material/ComponentIncorrect tubing.
Jun 11, 2015Class IIZ-2202-2015Mixed-up of materials/componentsThe ARCHITECT c8000 instrument contains tubing that does not meet specifications and has the potential to leak.
May 11, 2015Class IIZ-1725-2015Under Investigation by firmThe product is leaking from the cap and crystallization was noted as present around the cap.
Jan 15, 2015Class IIZ-0011-2018Device DesignThere is a potential to generate falsely-depressed patient results in the cuvettes adjacent to the detached segment post for any assay run on the c4000 instrument.
Jul 22, 2014Class IIZ-1932-2015Process controlICT Serum Calibrator may generate lower than expected Potassium Quality Control (QC) and patient results on the Abbott Architect cSystem.
May 23, 2008Not classifiedZ-2231-2008Software designSoftware defect can allow tests ordered for one sample to be aspirated from a different sample, reporting erroneous results for the affected sample.
Sep 26, 2007Not classifiedZ-1166-2008Component design/selectionQuality Control (Out of Range)- ICT Calibrator lot number: 0505017, may contain an interferent. Not all vials within a kit are affected. The investigation determined that the interferent affects Potassium (K+) only. Use of the affected…
Sep 5, 2007Not classifiedZ-0146-2008Software change controlIncorrect Sample/Test Identification: Due to a software timing defect with certain versions of ARCHITECT cSystem Software, test results may be incorrectly associated to a Sample Identification during specific sample-processing conditions…
Apr 30, 2007Not classifiedZ-0952-2007OtherOne or more of four software issues : 1) calculation error for Architect cSystem assays using the Spline math model. 2) The system configuration option, Run controls onboard reagents by Kit, does not function correctly for assays…
Dec 8, 2005Not classifiedZ-0398-06OtherSystem software assigns a calibrator default volume of 2.0uL when field is left empty by operator at time assay parameters set. Patient results could be affected if the volume required is not 2.0 uL.
Sep 14, 2005Not classifiedZ-0010-06OtherSoftware deficiency causing potential shift in absorbance readings for test results.
Feb 28, 2005Not classifiedZ-0008-06OtherDevice has incorrect notation associated with therapeutic drug monitoring assays.
Sep 24, 2004Not classifiedZ-0016-05OtherChanges to the printer default settings made by users/operators cause printed data to be truncated and misidentified.
Jun 10, 2004Not classifiedZ-1341-04OtherProcess change in the manufacturing of the AC/DC driver board used on the analyzer may result in one or more of the solid state relays to fail during use.
Mar 22, 2004Not classifiedZ-0846-04OtherChange of level 3 error log messages to level 1 to prevent suspect assay results.
Mar 19, 2004Not classifiedZ-0818-04OtherWhen using a LIS the software system will send up a test result of up to 20 characters although the field is set to display only 15 characters per the RS-232 Manual.
Nov 17, 2003Not classifiedZ-0263-04OtherSample Identification (SID) numbers of a bar coded sample may be truncated, or shortened, after being scanned by the bar code reader (e.g. an actual SID of 123456 is shortened to 1234)
Sep 30, 2003Not classifiedZ-0091-04OtherAudible alarm occurs before aspiration potentially resulting in operator injury or results assigned to wrong patient for STAT samples.
Feb 24, 2003Not classifiedZ-0725-03OtherUnder certain operating conditions, smart wash feature disables with multiple samples.
Feb 24, 2003Not classifiedZ-0788-03OtherSoftware failure to detect error in reference solution set-up can cause inaccurate results for Sodium, Potassium, and Chloride.
Jan 27, 2003Not classifiedZ-0796-03OtherExternal waste pump has metal edge around perimeter sharp enough to cause scratch or cut.
Aug 15, 2002Not classifiedZ-0844-03OtherDesign of high concentration waste line causes formation of a precipitate in the waste line causing overflow of waste.
Oct 2, 2001Not classifiedZ-0843-03OtherExtensive use of cuvettes causes inaccurate results. Preventative maintenance did not specify replacement schedule.
Dec 29, 2000Not classifiedZ-1142-03OtherICT assays run using a manual dilution will not be calculated correctly by the software.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • Of its descendants, K093318 (Abbott Laboratories, 2010) has gone furthest, with 3 descendants of its own.
  • 4 other devices also cite its predicate K872494.

How does its category compare?

All CGZ devices

CGZ Electrode, Ion-Specific, Chloride: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · CGZ

1in 2018

2007: 12008: 22016: 12017: 12018: 1
2007high 2 (2008) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CGZ

Too few CGZ 510(k)s in any year since 2007 to give a median.

Recalls per year · CGZ

2in 2019

2007: 12008: 12009: 12011: 12019: 2
2007high 2 (2019) · low 0 (2010)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · CGZ

5in 2025

2007: 42009: 12010: 72011: 52012: 302013: 422014: 102015: 22016: 12017: 22018: 192019: 32020: 32022: 52023: 92024: 62025: 5
2007high 42 (2013) · low 0 (2008)2025

MAUDE reports naming product code CGZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—14
20082—10
20090—11
20100—07
20110—15
20120—030
20130—042
20140—010
20150—02
20161—01
20171—02
20181—019
20190—23
20200—03
20210—00
20220—05
20230—09
20240—06
20250—05
20260—0—

What is it indicated for?

Per 21 CFR 862.2160, the AEROSET System is a discrete photometric chemistry Analyzer for clinical use. The device is intended to duplicate manual analytical procedures by performing various steps such as pipetting, heating, and measuring color intensity. This device is intended for use in conjunction with certain materials to measure a variety of analytes. The AEROSET System also has a solid state Ion-Selective Electrode module, trademarked as Integrated Chip Technology™ (ICT), utilizing potentiometry, for electrolyte determinations (sodium, potassium, and chloride).

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K980367: Aeroset System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K980367

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026