510(k) · Cleared
ClearedDatascope Percor Stat-DL 9.5 FR. 25, 34 and 40CC Intra-Aoric Balloons with Alternate B Membrane for Optional Sheathles
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Datascope Corp. · DSP System, Balloon, Intra-Aortic And Control
Cleared on May 29, 1998 as substantially equivalent to K905056 (Datascope Corp., 1991) and 9 other predicates after an 88-day review. Its family tree reaches back 2 generations to 1991. 5 of the 32 devices in its family, counting itself, have a Class I recall. 16 later devices descend from it.
- Decided
- May 29, 1998
- Review
- 88 days
- Class
- Class II
- Product code
- DSP
- Recalls
- None
- Predicates
- 11
Its longest line of descent runs back 2 generations to K905056 (1991). 15 ancestors in all, the oldest K790775 (1979). 16 later devices descend from it, 2 citing it directly. 5 of the 32 devices in this family, counting this one, have a Class I recall.
- Root · 2 generations backK905056 Percor Stat-DL 9.5 FR W/Opt Insert W/O Intro SheatDatascope Corp. · 1991
- 1 generation backK960166 Percor Stat-DL 9.5 FR. 34 & 40CCDatascope Corp. · 1996
- This deviceK980780 Datascope Percor Stat-DL 9.5 FR. 25, 34 and 40CC Intra-Aoric…Datascope Corp. · 1998
- Descendant · cites it directly · 15 of its ownK994157 Datascope's 8FR. Polymide 25CC,34CC and 40CC Iab and Accessories…Datascope Corp. · 2000
- Descendant · 2 generations on · 14 of its ownK013326 Modification to: Datascope 8FR. Polyimide Alt B Iab, 25CC, 34CC…Datascope Corp. · 2001
- Descendant · 3 generations on · 12 of its ownK031569 Datascope CA 40 8FR. Iabs, Model 0684-00-04XXDatascope Corp. · 2003
- Descendant · 3 generations on · 11 of its ownK041281 Datascope 7.5FR. Iab Catheter and AccessoriesDatascope Corp. · 2004 · Recalled
- Descendant · 3 generations on · 8 of its ownK063525 Datascope Fiber Optic Pressure Sensor Intra-Aortic Balloon Catheter…Datascope Corp. · 2007 · Recalled (Class I)
Showing 5 of 16 descendants. See all descendants
Descendants cleared per year
Class I recalls in this family
Most influential descendants
Showing 5 of 16 · See all- K994157Datascope's 8FR. Polymide 25CC,34CC and 40CC Iab and Accessories, Models 0684-00-0327…Datascope Corp. · 2000 · cites it directly15descendants
- K013326Modification to: Datascope 8FR. Polyimide Alt B Iab, 25CC, 34CC, 40CC, Datascope…Datascope Corp. · 2001 · 2 generations on14descendants
- K031569Datascope CA 40 8FR. Iabs, Model 0684-00-04XXDatascope Corp. · 2003 · 3 generations on12descendants
- K041281Datascope 7.5FR. Iab Catheter and AccessoriesDatascope Corp. · 2004 · 3 generations on11descendants
- K063525Datascope Fiber Optic Pressure Sensor Intra-Aortic Balloon Catheter and CS300…Datascope Corp. · 2007 · 3 generations on8descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −2 | K905056 | Percor Stat-DL 9.5 FR W/Opt Insert W/O Intro Sheat | Datascope Corp. | 1991 | — |
| −1 | K960166 | Percor Stat-DL 9.5 FR. 34 & 40CC | Datascope Corp. | 1996 | — |
| 0 (this device) | K980780 | Datascope Percor Stat-DL 9.5 FR. 25, 34 and 40CC Intra-Aoric Balloons with… | Datascope Corp. | 1998 | — |
| +1 | K994157 | Datascope's 8FR. Polymide 25CC,34CC and 40CC Iab and Accessories, Models… | Datascope Corp. | 2000 | — |
| +2 | K013326 | Modification to: Datascope 8FR. Polyimide Alt B Iab, 25CC, 34CC, 40CC… | Datascope Corp. | 2001 | — |
| +3 | K031569 | Datascope CA 40 8FR. Iabs, Model 0684-00-04XX | Datascope Corp. | 2003 | — |
| +3 | K041281 | Datascope 7.5FR. Iab Catheter and Accessories | Datascope Corp. | 2004 | 7 |
| +3 | K063525 | Datascope Fiber Optic Pressure Sensor Intra-Aortic Balloon Catheter and CS300… | Datascope Corp. | 2007 | Class I |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1979 | 1 | 0 |
| 1989 | 1 | 0 |
| 1991 | 1 | 0 |
| 1993 | 1 | 0 |
| 1994 | 2 | 0 |
| 1995 | 3 | 0 |
| 1996 | 2 | 0 |
| 1997 | 2 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2000 | 1 | 0 |
| 2001 | 1 | 0 |
| 2002 | 1 | 0 |
| 2003 | 1 | 0 |
| 2004 | 1 | 0 |
| 2007 | 1 | 1 |
| 2009 | 2 | 0 |
| 2011 | 2 | 1 |
| 2012 | 1 | 0 |
| 2013 | 1 | 0 |
| 2015 | 1 | 1 |
| 2017 | 2 | 1 |
| 2018 | 1 | 1 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
5 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DSP device
- #1 K250542 AC3™ Range™ Intra-Aortic Balloon Pumpscore 11.2 · 8 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (11)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary; numbers the summary cites that cannot be its predicate are marked – and kept off the family tree.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K905056 | Percor Stat-DL 9.5 FR W/Opt Insert W/O Intro SheatSummary page 1…535 Product Code: 74DSP PREDICATE DEVICE INFORMATION Datascope’s Percor STAT-DL® Intra-Aortic Balloon is substantially equivalent to the following marketed devices: - K905056- Datascope Percor STAT-DL 9.5Fr. with Optional Insertion without an Introducer Sheath - K910997- Datascope Percor STAT IABs with… | 1991 |
| * | K910997 | Datascope Percor Stat Intra-Aortic BalloonSummary page 1…alloon is substantially equivalent to the following marketed devices: - K905056- Datascope Percor STAT-DL 9.5Fr. with Optional Insertion without an Introducer Sheath - K910997- Datascope Percor STAT IABs with Alternate Coating - K940178- Datascope Percor STAT-DL®9.5Fr. 34 & 40cc IABs - K940231- Datasco… | 1991 |
| * | K940178 | Percor Stat-DL 9.5 FR.34CC & 40CC /Percor Stat-DL 10.5 FR.40CC & 50CC Intra-Aortic…Summary page 1…evices: - K905056- Datascope Percor STAT-DL 9.5Fr. with Optional Insertion without an Introducer Sheath - K910997- Datascope Percor STAT IABs with Alternate Coating - K940178- Datascope Percor STAT-DL®9.5Fr. 34 & 40cc IABs - K940231- Datascope Percor STAT-DL 9.5Fr. 40cc IAB Page 25 Sum… | 1994 |
| * | K940231 | Intra-Aortic Balloon for Optional Sheathless InsertionSummary page 1…tional Insertion without an Introducer Sheath - K910997- Datascope Percor STAT IABs with Alternate Coating - K940178- Datascope Percor STAT-DL®9.5Fr. 34 & 40cc IABs - K940231- Datascope Percor STAT-DL 9.5Fr. 40cc IAB Page 25 Summary of Safety & Effectiveness/Datascope Percor STAT-DL®9.5… | 1994 |
| Kept off the family tree | K943846 | Datascope’s Staged Guidewire Not in FDA’s 510(k), De Novo or PMA lists as we hold them (a misreading, a typo, or a number FDA does not list), so it is kept off the family tree Summary page 2…40cc IABs - K940231- Datascope Percor STAT-DL 9.5Fr. 40cc IAB Page 25 Summary of Safety & Effectiveness/Datascope Percor STAT-DL®9.5 Fr. IAB Page 2 - K943846 - Datascope’s Staged Guidewire - K960166- Datascope Percor STAT-DL 9.5Fr. 34 & 40cc IABs for Optional Sheathless Insertion - K9… | |
| * | K960166 | Percor Stat-DL 9.5 FR. 34 & 40CCSummary page 2…AT-DL 9.5Fr. 40cc IAB Page 25 Summary of Safety & Effectiveness/Datascope Percor STAT-DL®9.5 Fr. IAB Page 2 - K943846 - Datascope’s Staged Guidewire - K960166- Datascope Percor STAT-DL 9.5Fr. 34 & 40cc IABs for Optional Sheathless Insertion - K964987- Datascope Percor STAT DL 9.5Fr. 25… | 1996 |
| * | K964987 | Datascope Percor Stat - DL 9.5 FR. 25 and 40CC Intra-Aortic Balloon for Optional…Summary page 2…rcor STAT-DL®9.5 Fr. IAB Page 2 - K943846 - Datascope’s Staged Guidewire - K960166- Datascope Percor STAT-DL 9.5Fr. 34 & 40cc IABs for Optional Sheathless Insertion - K964987- Datascope Percor STAT DL 9.5Fr. 25 & 40cc IABs for Optional Sheathless Insertion - K960713 - Arrow International 8 Fr. 40 Narro… | 1997 |
| * | K960713 | 8 FR.-40CC Arrow Flex Intra-Aortic Balloon Catheter with Blue Flex Tip, Product Number…Summary page 2…pe Percor STAT-DL 9.5Fr. 34 & 40cc IABs for Optional Sheathless Insertion - K964987- Datascope Percor STAT DL 9.5Fr. 25 & 40cc IABs for Optional Sheathless Insertion - K960713 - Arrow International 8 Fr. 40 NarrowFlex™ IAB - K892799 - Arrow International 8 Fr. 30cc IAB - K945230 - Arrow International Kin… | 1996 |
| * | K892799 | 8 FR Percutan Double Lumen Intra-Aortic BalloonSummary page 2…thless Insertion - K964987- Datascope Percor STAT DL 9.5Fr. 25 & 40cc IABs for Optional Sheathless Insertion - K960713 - Arrow International 8 Fr. 40 NarrowFlex™ IAB - K892799 - Arrow International 8 Fr. 30cc IAB - K945230 - Arrow International Kink Resistant 9.5 Fr. Flexi-Cath IAB - K963104 - Arrow Int… | 1989 |
| * | K945230 | Arrow Kink Resistant Flexi-Cath Intra-Aortic BalloonSummary page 2…TAT DL 9.5Fr. 25 & 40cc IABs for Optional Sheathless Insertion - K960713 - Arrow International 8 Fr. 40 NarrowFlex™ IAB - K892799 - Arrow International 8 Fr. 30cc IAB - K945230 - Arrow International Kink Resistant 9.5 Fr. Flexi-Cath IAB - K963104 - Arrow International 9.5 Fr. Flexi-Cath IAB D. DEVIC SCR… | 1995 |
| * | K963104 | 9.5 FR.- Flexi-Cath Intra-Aortic and Control SystemSummary page 2…13 - Arrow International 8 Fr. 40 NarrowFlex™ IAB - K892799 - Arrow International 8 Fr. 30cc IAB - K945230 - Arrow International Kink Resistant 9.5 Fr. Flexi-Cath IAB - K963104 - Arrow International 9.5 Fr. Flexi-Cath IAB D. DEVIC SCRIPTION/INTENDED USE The intra-aortic balloon is placed in the descendin… | 1997 |
What descends from it? (16)
See all 162 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (5 Class I)
No FDA recall names this device.
Relatives with a Class I recall
Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.
- K063525Datascope Fiber Optic Pressure Sensor Intra-Aortic Balloon Catheter and CS300 Intra-Aortic Balloon Pump…Datascope Corp. · 2007 · 3 generations on · ◆ in the 2007 descendants bar of FIG. 11 Class I recall
- K112372Cardiosave Hybrid Intra-Aortic Balloon PumpCardiac Assist, Maquet Cardiovascular, LLC · 2011 · 4 generations on · ◆ in the 2011 descendants bar of FIG. 110 Class I recalls
- K181122CARDIOSAVE Intra-Aortic Balloon PumpDatascope Corp. · 2018 · 5 generations on · ◆ in the 2018 descendants bar of FIG. 127 Class I recalls
- K151254CARDIOSAVE Hybrid Intra-Aortic Balloon PumpDatascope Corp. · 2015 · 5 generations on · ◆ in the 2015 descendants bar of FIG. 112 Class I recalls
- K163542CARDIOSAVE Hybrid and Rescue Intra-Aortic Balloon Pump, CARDIOSAVE Li-Ion Battery Transport and Storage CaseDatascope Corp. · 2017 · 6 generations on · ◆ in the 2017 descendants bar of FIG. 17 Class I recalls
What does this lineage say?
- The line of descent spans 7 years and passes through 1 company; a new generation was cleared every 4.9 years on median.
- 1 of the 15 ancestors has a recall of any class.
- Of its descendants, K994157 (Datascope Corp., 2000) has gone furthest, with 15 descendants of its own.
- 2 other devices also cite its predicate K905056.
How does its category compare?
All DSP devicesDSP System, Balloon, Intra-Aortic And Control: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · DSP
1in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DSP
140in 2019
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DSP
4in 2025
Class I (47 since 2007) Class II/III not classified
Adverse event reports per year · DSP
7,422in 2025
MAUDE reports naming product code DSP, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 2 | — | 3 | 461 |
| 2008 | 0 | — | 0 | 617 |
| 2009 | 2 | — | 14 | 656 |
| 2010 | 0 | — | 8 | 1,019 |
| 2011 | 2 | — | 0 | 590 |
| 2012 | 2 | — | 3 | 490 |
| 2013 | 1 | — | 0 | 495 |
| 2014 | 0 | — | 1 | 1,738 |
| 2015 | 1 | — | 0 | 404 |
| 2016 | 0 | — | 9 (9) | 419 |
| 2017 | 3 | 73 | 0 | 2,164 |
| 2018 | 1 | — | 2 (2) | 3,331 |
| 2019 | 3 | 140 | 3 | 3,552 |
| 2020 | 2 | — | 0 | 3,393 |
| 2021 | 0 | — | 5 (3) | 4,345 |
| 2022 | 0 | — | 33 (33) | 5,113 |
| 2023 | 1 | — | 0 | 6,980 |
| 2024 | 0 | — | 1 | 7,317 |
| 2025 | 1 | — | 4 | 7,422 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
Refractory ventricular failure.
Cardiogenic shock.
Unstable refractory angina.
Impending infarction.
Mechanical complications due to acute myocardial infarction, i.e., ventricular septal defect, mitral regurgitation or papillary muscle rupture.
Ischemia related intractable ventricular arrhythmias.
Cardiac support for high risk general surgical patients and coronary angiography/angioplasty patients.
Septic shock.
Weaning from cardiopulmonary-bypass.
Intraoperative pulsatile flow generation.
Support for failed angioplasty and valvuloplasty
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K980780 · printed Nov 5, 2026
Cite this page
510(k) Report. “K980780: Datascope Percor Stat-DL 9.5 FR. 25, 34 and 40CC Intra-Aoric Balloons with Alternate B Membrane for Optional Sheathles.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K980780
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026