IN-Check Inspiratory Flowmeter

K980960510(k) TraditionalCleared Jun 10, 199886-day reviewClass II21 CFR 868.1860

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Clement Clarke Intl., Ltd. · BZH Meter, Peak Flow, Spirometry

Cleared on Jun 10, 1998 after an 86-day review. The FDA summary names no predicate by number.

Decided
Jun 10, 1998
Review
86 days
Class
Class II
Product code
BZH
Recalls
None
Predicates
0

The FDA summary names no predicate by number.

FIG. 1 — Lineage of K980960Source: FDA 510(k) database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in BZH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new BZH device

  1. #1 K252802 Peak Flow Meter (PF-10(BR-PEF231))score 13.5 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

The FDA summary names no predicate by number.

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

How does its category compare?

All BZH devices

BZH Meter, Peak Flow, Spirometry: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · BZH

3in 2024

2009: 22010: 22013: 12014: 12016: 12017: 12018: 32019: 12020: 22021: 12023: 12024: 32026 (partial year): 2
2007high 3 (2018) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · BZH

371in 2024

2018: 115 days median2024: 371 days median
2007high 371 (2024) · low 115 (2018)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · BZH

No recall names BZH since 2007.

Adverse event reports per year · BZH

1in 2015

2007: 12011: 12013: 32014: 222015: 1
2007high 22 (2014) · low 0 (2008)2025

MAUDE reports naming product code BZH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—01
20080—00
20092—00
20102—00
20110—01
20120—00
20131—03
20141—022
20150—01
20161—00
20171—00
2018311500
20191—00
20202—00
20211—00
20220—00
20231—00
2024337100
20250—00
20262—0—

What is it indicated for?

The IN-CHECK is one of a family of simple devices used for monitoring respiratory conditions, and is suitable for use by the Health Care Professional or for home monitoring of nasal or oral inspiratory flow by the patient. Some uses for the device are :- 1. Diagnosis of Nasal Obstruction In some patients who complain of nasal obstruction, nasal airway patency is quite normal, and the symptom is due to consciousness of some other abnormality of the nasal…

Read the full statement (387 words)

The IN-CHECK is one of a family of simple devices used for monitoring respiratory conditions, and is suitable for use by the Health Care Professional or for home monitoring of nasal or oral inspiratory flow by the patient.

Some uses for the device are :-

1. Diagnosis of Nasal Obstruction

In some patients who complain of nasal obstruction, nasal airway patency is quite normal, and the symptom is due to consciousness of some other abnormality of the nasal cavity such as a prominent turbinate. In some cases, surprisingly low readings are obtained in some patients who are unaware of nasal obstruction, because they have got used to it. Quiet breathing through the nose can in such cases be achieved in spite of a peak nasal inspiratory flow readings as low as 50.

Such patients are often unaware that they breath through the mouth for much of the time.

Reversibility of nasal obstruction can be assessed by measuring PNIF after application of a nasal decongestant such as ephedrine by spray or drops. If the PNIF is not raised to a reading of over 100 by such treatment, then the obstruction may be associated with mucosal oedema, extensive polyps or anatomical abnormality. A trial of topical or systemic steroids may also bring the PNIF into the normal range (100 to 300 L/min.).

2. Assessment of Response to Nasal Provocation

Allergen or pharmocological mediator (e.g. histamine) application to the nasal mucosa in doses halving PNIF is usually associated with only minor and transient discomfort. Details of a simplified allergen provocation test using PNIF measurement have been published.

3. Home Monitoring of PNIF

This may be useful in drug or immunotherapy trials in rhinitis, or for assessing the importance of environmental factors at home or work in individual patients with rhinitis. Cyclic changes in nasal airway patency can also be investigated, as can late responses to allergen provocation.

4. Oral Inspiratory Flow Measurement

Measurements of sub-maximal inspiratory flows are valuable when training patients in the correct use of medical inhaler devices. Recent studies have indicated target inspiratory flows for many of the inhaled medication devices commonly used to deliver medication in respiratory diseases.

Feedback to the patient from IN-CHECK measurement enables the patient to adjust their inhalation technique to best suit their own inhaler.

Note: PNIF = Peak Nasal Inspiratory Flow

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K980960: IN-Check Inspiratory Flowmeter.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K980960

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Page last updated Nov 3, 2026