510(k) · Cleared
ClearedMotility Probe Model Numbers P31 Thru P38, P40 Thru P43 and P50
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Konigsberg Instruments, Inc. · FFX System, Gastrointestinal Motility (Electrical)
Cleared on Jun 15, 1998 after a 90-day review. FDA’s file for it is a 510(k) statement, which names no predicate.
- Decided
- Jun 15, 1998
- Review
- 90 days
- Class
- Class II
- Product code
- FFX
- Recalls
- None
- Predicates
- 0
FDA’s file for it is a 510(k) statement, which names no predicate.
Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in FFX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new FFX device
- #1 K262621 Rapid Barostat Bag (RBB) Pump and Catheter…score 12.4 · 2 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA’s file for it is a 510(k) statement, which names no predicate.
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All FFX devicesFFX System, Gastrointestinal Motility (Electrical): FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · FFX
1in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · FFX
123in 2023
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · FFX
2so far in 2026, the most since 2007
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · FFX
32in 2025
MAUDE reports naming product code FFX, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 2 | — | 0 | 0 |
| 2008 | 1 | — | 0 | 0 |
| 2009 | 2 | — | 1 | 2 |
| 2010 | 2 | — | 0 | 6 |
| 2011 | 0 | — | 1 | 6 |
| 2012 | 4 | 120 | 0 | 4 |
| 2013 | 1 | — | 0 | 4 |
| 2014 | 0 | — | 0 | 4 |
| 2015 | 0 | — | 0 | 10 |
| 2016 | 3 | 145 | 0 | 15 |
| 2017 | 2 | — | 0 | 10 |
| 2018 | 1 | — | 0 | 17 |
| 2019 | 4 | 240 | 0 | 27 |
| 2020 | 1 | — | 0 | 20 |
| 2021 | 0 | — | 0 | 26 |
| 2022 | 0 | — | 0 | 31 |
| 2023 | 3 | 123 | 0 | 51 |
| 2024 | 1 | — | 0 | 59 |
| 2025 | 1 | — | 0 | 32 |
| 2026 | 1 | — | 2 | — |
What is it indicated for?
The Koni’gsberg Instruments’ Motility Probe is manufactured for use in the evaluation and diagnosis of gastrointestinal dysfunction related to muscle tonus and the coordination of contractions between muscle groups.
The Motility Probe provides several types of information which may be used in these diagnoses. Primary among these is pressure information at many of the sensor sites. Secondary to the pressure information is the ability of the probe to measure pH in the stomach and esophagus. This can reveal the presence of gastric reflux from the stomach into the esophagus.
Indications for use read by OCR from a scanned FDA 510(k) statement, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K980980 · printed Nov 6, 2026
Cite this page
510(k) Report. “K980980: Motility Probe Model Numbers P31 Thru P38, P40 Thru P43 and P50.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K980980
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)