510(k) · Cleared
ClearedTFR
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Ramco Laboratories, Inc. · JNM Immunochemical, Transferrin
Cleared on Oct 21, 1998 as substantially equivalent to K970718 (R&D Systems, Inc., 1997) after a 202-day review. Its family tree reaches back 2 generations to 1993.
- Decided
- Oct 21, 1998
- Review
- 202 days
- Class
- Class II
- Product code
- JNM
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 2 generations to K926221 (1993). No later device cites it as a predicate yet.
View FIG. 1 as a table
Line of descent and top descendants
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JNM? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K970718 | Quantikine Ivd STFR Enzyme Linked Immunosorbent Assay (Elisa)Summary page 1…ceptor Assay IR TfR Assay sTfR Immunological Test System Quantikine IVD sTfR Immunoassay R&D Systems, Inc. 614 McKinley Place N.E. . Minneapolis, MN 55413 ™ 510(k) #K970718 The TfR assay is an in vitro enzyme immunoassay based upon the double antibody sandwich method. Plasma or serum samples are dilu… | 1997 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 5 years and passes through 3 companies; a new generation was cleared every 4.4 years on median.
- 2 of the 2 ancestors have a recall of any class.
- 3 other devices also cite its predicate K970718.
How does its category compare?
All JNM devicesJNM Immunochemical, Transferrin: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · JNM
FDA has decided no JNM device since 2007.
Median 510(k) review, days · JNM
Too few JNM 510(k)s in any year since 2007 to give a median.
Recalls per year · JNM
1in 2018
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · JNM
1in 2011
MAUDE reports naming product code JNM, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 0 | — | 0 | 0 |
| 2009 | 0 | — | 0 | 0 |
| 2010 | 0 | — | 0 | 0 |
| 2011 | 0 | — | 0 | 1 |
| 2012 | 0 | — | 0 | 0 |
| 2013 | 0 | — | 0 | 0 |
| 2014 | 0 | — | 0 | 0 |
| 2015 | 0 | — | 0 | 0 |
| 2016 | 0 | — | 0 | 0 |
| 2017 | 0 | — | 0 | 0 |
| 2018 | 0 | — | 1 | 0 |
| 2019 | 0 | — | 0 | 0 |
| 2020 | 0 | — | 0 | 0 |
| 2021 | 0 | — | 0 | 0 |
| 2022 | 0 | — | 0 | 0 |
| 2023 | 0 | — | 0 | 0 |
| 2024 | 0 | — | 0 | 0 |
| 2025 | 0 | — | 0 | 0 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
The TfR assay is an in vitro enzyme immunoassay for quantifying the concentration of transferrin receptor in human serum or plasma to aid in the diagnosis of iron deficiency anemia, particularly in the presence of other disease states.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K981208 · printed Nov 5, 2026
Cite this page
510(k) Report. “K981208: TFR.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K981208
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026