510(k) Report

510(k) · Cleared

Recalled · 2007

Clearstar Enteral Nutrition Pump

K981541510(k) TraditionalCleared Aug 13, 1998106-day reviewClass II21 CFR 880.5725Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Frantz Medical Development, Ltd. · LZH Pump, Infusion, Enteral

Cleared on Aug 13, 1998 after a 106-day review. The FDA summary names no predicate by number. 1 later device descends from it. It has been recalled once.

Decided
Aug 13, 1998
Review
106 days
Class
Class II
Product code
LZH
Recalls
1
Predicates
0

1 later device descends from it, 1 citing it directly.

Descendants, by year cleared 2006: 1 descendant cleared1995200020052010201520202025
  1. This deviceK981541 Clearstar Enteral Nutrition PumpFrantz Medical Development, Ltd. · 1998
  2. Descendant · cites it directly · 0 of its ownK060316 Compat GO Enteral Feeding Pump and Administration SetsFresenius Kabi Deutschland GmbH · 2006

Most influential descendants

Showing 1 of 1 · See all
  • K060316Compat GO Enteral Feeding Pump and Administration SetsFresenius Kabi Deutschland GmbH · 2006 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K981541Clearstar Enteral Nutrition PumpFrantz Medical Development, Ltd.1998—
+1K060316Compat GO Enteral Feeding Pump and Administration SetsFresenius Kabi Deutschland GmbH2006—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200610
FIG. 1 — Lineage of K981541, 1998–2006Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LZH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LZH device

  1. #1 K253558 Luminoah FLOW™ Enteral Nutrition Systemscore 13.0 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

The FDA summary names no predicate by number.

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K060316Compat GO Enteral Feeding Pump and Administration SetsFresenius Kabi Deutschland GmbH20060

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jun 21, 2007Not classifiedZ-1142-2007Equipment maintenanceThe transducer adapter bracket on the pump could crack or break and potentially result in under delivery of the enteral product.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K060316 (Fresenius Kabi Deutschland GmbH, 2006) has gone furthest, with 0 descendants of its own.

How does its category compare?

All LZH devices

LZH Pump, Infusion, Enteral: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · LZH

1in 2023

2012: 12014: 22015: 12016: 12020: 12022: 22023: 12026 (partial year): 1
2007high 2 (2014) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LZH

Too few LZH 510(k)s in any year since 2007 to give a median.

Recalls per year · LZH

2in 2020

2007: 22008: 32009: 12011: 12012: 22020: 2
2007high 3 (2008) · low 0 (2010)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LZH

376in 2025

2007: 1,1502008: 8582009: 1242010: 2202011: 2742012: 3982013: 3492014: 1192015: 832016: 1,2482017: 2,6202018: 1,6522019: 7422020: 1,4602021: 1,2182022: 5262023: 2842024: 3192025: 376
2007high 2,620 (2017) · low 83 (2015)2025

MAUDE reports naming product code LZH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—21,150
20080—3858
20090—1124
20100—0220
20110—1274
20121—2398
20130—0349
20142—0119
20151—083
20161—01,248
20170—02,620
20180—01,652
20190—0742
20201—21,460
20210—01,218
20222—0526
20231—0284
20240—0319
20250—0376
20261—0—

What is it indicated for?

The ClearStar pump can be used for adult and pediatric patients provided the patients can tolerate a feeding range within the pump operational specifications. Those specifications are: * The flow rate range is 1-300 mL/hr in 1 mL/hr increments * The flow rate accuracy is ± 10% or ± 0.5 mL/hr, whichever is greater * The occlusion pressure limit is 26-30 psi. If these specifications are not appropriate for a given patient, the ClearStar pump should not be…

Read the full statement (191 words)

The ClearStar pump can be used for adult and pediatric patients provided the patients can tolerate a feeding range within the pump operational specifications. Those specifications are:

* The flow rate range is 1-300 mL/hr in 1 mL/hr increments

* The flow rate accuracy is ± 10% or ± 0.5 mL/hr, whichever is greater

* The occlusion pressure limit is 26-30 psi.

If these specifications are not appropriate for a given patient, the ClearStar pump should not be used.

Precautions

All enteral pumps have the potential to bolus-feed or over deliver, which is an important consideration in feeding volume-sensitive patients. In these patients, a volume of product no more than four times the hourly feeding rate should be hung.

Confirm proper placement and function.

Confirm proper placement and function of patient’s enteral feeding tube (nasogastric, jejunostomy, gastrostomy, etc.), and verify the following before initiating feeding:

A ClearStar Pump Set is being used.

Cassette is properly seated in pump.

When on AC power, pump is fully seated in charger.

Flow rate is set at the prescribed mL/hr.

Pump dial is turned to RUN.

Note: The Power Supply Cord is the DISCONNECT DEVICE.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K981541: Clearstar Enteral Nutrition Pump.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K981541

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026