510(k) Report

510(k) · Cleared

Cleared

Biopak Measurement System

K981563510(k) TraditionalCleared Sep 15, 1998137-day reviewClass II21 CFR 890.1375

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Bio-Research Associates, Inc. · KZM Device, Muscle Monitoring

Cleared on Sep 15, 1998 after a 137-day review. FDA’s file for it is a 510(k) statement, which names no predicate.

Decided
Sep 15, 1998
Review
137 days
Class
Class II
Product code
KZM
Recalls
None
Predicates
0

FDA’s file for it is a 510(k) statement, which names no predicate.

FIG. 1 — Lineage of K981563Source: FDA 510(k) database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KZM? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

How does its category compare?

All KZM devices

KZM Device, Muscle Monitoring: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · KZM

1in 2016

2009: 12012: 12013: 12016: 1
2007high 1 (2009) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KZM

Too few KZM 510(k)s in any year since 2007 to give a median.

Recalls per year · KZM

No recall names KZM since 2007.

Adverse event reports per year · KZM

No MAUDE report names KZM since 2007.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20091—00
20100—00
20110—00
20121—00
20131—00
20140—00
20150—00
20161—00
20170—00
20180—00
20190—00
20200—00
20210—00
20220—00
20230—00
20240—00
20250—00
20260—0—

What is it indicated for?

At the present time, comparisons between patients of electromyograms, sonograms and / or jaw traces should not be made. Sufficient normative data have not been collected to support such population-based measurements as “mean electromyographic clench,” “standard deviation (Jaw Tracking) of freeway space,” “integral (sonograph) of sound intensity,” “average jaw tracing of chewing,” etc., for non diseased individuals as well as for patients having various…

Read the full statement (328 words)

At the present time, comparisons between patients of electromyograms, sonograms and / or jaw traces should not be made.

Sufficient normative data have not been collected to support such population-based measurements as “mean electromyographic clench,” “standard deviation (Jaw Tracking) of freeway space,” “integral (sonograph) of sound intensity,” “average jaw tracing of chewing,” etc., for non diseased individuals as well as for patients having various disease entities that are now lumped within the terminology known as ‘Temporomandibular Disorders and Associated Orofacial Pain (TMD/MPD)."

Jaw Tracking

1. To track mandibular movement and position

2. To aid in the diagnosis of TMJ/ MPD syndrome, muscle tension and bruxing [instability of occlusion]

3 To identify mandibular rest position and to identify interocclusal distance and freeway space

4. To monitor the position of the jaw in three dimensions

5. To represent the spatial position of the mandibular incisal edge relative to the skull

To provide Baseline measurements for future reference

Electromyography

1. To record electrical activity of muscles of the stomatognathic system, especially temporalis, masseter and digastric

2. To clinically monitor up to eight different muscles as an aid in diagnosis and treatment evaluation by recording the electrical activity of the muscles of the stomatognathic system.

3. To determine the degree of relaxation (intra-patient) of a single muscle / group of muscles at rest

4. To measure relative (intra-patient) levels of activity of several muscles during a functional act

To provide Baseline measurements for future reference

Sonography, joint vibration (sound) recording

1. To record and display sounds / vibrations from the temporomandibular joint

2. To aid the clinician in his analysis of a joint sound / vibration by allowing him to see the waveform in various standard plots

3. To aid the clinician in comparing a patient’s current standard plots to previous recordings before, during and after treatment

4 To provide numerical values that can be used to quantify the physical characteristics of the sounds

5. To provide Baseline measurements for future reference

Indications for use read by OCR from a scanned FDA 510(k) statement, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K981563: Biopak Measurement System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K981563

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Page last updated Nov 3, 2026