510(k) Report

510(k) · Cleared

Cleared

Short Straight-in Bone Screw Fixation System

K982155510(k) TraditionalCleared Aug 31, 199874-day reviewClass II21 CFR 888.3040

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Influence, Inc. · MBI Fastener, Fixation, Nondegradable, Soft Tissue

Cleared on Aug 31, 1998 as substantially equivalent to K972622 (Influence, Inc., 1997) after a 74-day review. Its family tree reaches back 4 generations to 1992. 12 later devices descend from it.

Decided
Aug 31, 1998
Review
74 days
Class
Class II
Product code
MBI
Recalls
None
Predicates
1

Its longest line of descent runs back 4 generations to K920213 (1992). 7 ancestors in all. 12 later devices descend from it, 2 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1994: 1 other ancestor1996: 1 other ancestor1995: 1 other ancestor1999: 1 descendant cleared2006: 2 descendants cleared2008: 1 descendant cleared2018: 1 descendant cleared2009: 1 descendant cleared2010: 1 descendant cleared2021: 1 descendant cleared2011: 1 descendant cleared2012: 1 descendant cleared2024: 1 descendant cleared2023: 1 descendant clearedK920213 · Mitek Anchor, Mitek Anchor II · Mitek Surgical Products, Inc. · 1992K962372 · Urotac Bone Anchor Inserter · Influence, Inc. · 1996K970292 · IN-Fast Bone Screw System/in-Fast Bone Screw Inserter/in-Fast Bone Screw · Influence, Inc. · 1997 · recalledK972622 · Straight-in Bone Screw Fixation System · Influence, Inc. · 19971990200020102020
Other ancestors, by generationDescendants, by generation 2 generations back: 1 other ancestor3 generations back: 2 other ancestors 1 generation forward: 2 descendants2 generations forward: 3 descendants3 generations forward: 3 descendants4 generations forward: 3 descendants5 generations forward: 1 descendant K972622 · Straight-in Bone Screw Fixation System · Influence, Inc. · 1997K970292 · IN-Fast Bone Screw System/in-Fast Bone Screw Inserter/in-Fast Bone Screw · Influence, Inc. · 1997 · recalledK962372 · Urotac Bone Anchor Inserter · Influence, Inc. · 1996K920213 · Mitek Anchor, Mitek Anchor II · Mitek Surgical Products, Inc. · 19920+5
  1. Root · 4 generations backK920213 Mitek Anchor, Mitek Anchor IIMitek Surgical Products, Inc. · 1992
  2. 3 generations backK962372 Urotac Bone Anchor InserterInfluence, Inc. · 1996
  3. 2 generations backK970292 IN-Fast Bone Screw System/in-Fast Bone Screw Inserter/in-Fast Bone…Influence, Inc. · 1997 · Recalled
  4. 1 generation backK972622 Straight-in Bone Screw Fixation SystemInfluence, Inc. · 1997
  5. This deviceK982155 Short Straight-in Bone Screw Fixation SystemInfluence, Inc. · 1998
  6. Descendant · cites it directly · 10 of its ownK053371 Ams Male Transobturator Sling SystemAmerican Medical Systems, Inc. · 2006 · Recalled
  7. Descendant · 2 generations on · 5 of its ownK082640 Virtue Ventral Urethral Elevation Sling SystemColoplast Manufacturing Us, LLC · 2008
  8. Descendant · 3 generations on · 4 of its ownK091152 Virtue Ventral Urethral Elevation Sling System, Model 50020Coloplast A/S · 2009
  9. Descendant · 3 generations on · 3 of its ownK101297 Virtue Ventral Urethral Elevation Sling System Model 50020Coloplast A/S · 2010
  10. Descendant · 2 generations on · 2 of its ownK182169 AdVance XP Male SlingBoston Scientific Corporation · 2018

Showing 5 of 12 descendants. See all descendants

Descendants cleared per year

1999: 12006: 22008: 12009: 12010: 12011: 12012: 12018: 12021: 12023: 12024: 1
1999high 2 (2006) · low 0 (2000)2026

Most influential descendants

Showing 5 of 12 · See all
  • K053371Ams Male Transobturator Sling SystemAmerican Medical Systems, Inc. · 2006 · cites it directly10descendants
  • K082640Virtue Ventral Urethral Elevation Sling SystemColoplast Manufacturing Us, LLC · 2008 · 2 generations on5descendants
  • K091152Virtue Ventral Urethral Elevation Sling System, Model 50020Coloplast A/S · 2009 · 3 generations on4descendants
  • K101297Virtue Ventral Urethral Elevation Sling System Model 50020Coloplast A/S · 2010 · 3 generations on3descendants
  • K182169AdVance XP Male SlingBoston Scientific Corporation · 2018 · 2 generations on2descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K920213Mitek Anchor, Mitek Anchor IIMitek Surgical Products, Inc.1992—
−3K962372Urotac Bone Anchor InserterInfluence, Inc.1996—
−2K970292IN-Fast Bone Screw System/in-Fast Bone Screw Inserter/in-Fast Bone ScrewInfluence, Inc.19971
−1K972622Straight-in Bone Screw Fixation SystemInfluence, Inc.1997—
0 (this device)K982155Short Straight-in Bone Screw Fixation SystemInfluence, Inc.1998—
+1K053371Ams Male Transobturator Sling SystemAmerican Medical Systems, Inc.20063
+2K082640Virtue Ventral Urethral Elevation Sling SystemColoplast Manufacturing Us, LLC2008—
+3K091152Virtue Ventral Urethral Elevation Sling System, Model 50020Coloplast A/S2009—
+3K101297Virtue Ventral Urethral Elevation Sling System Model 50020Coloplast A/S2010—
+2K182169AdVance XP Male SlingBoston Scientific Corporation2018—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199410
199510
199610

Descendants by year cleared

Year clearedDevicesWith a Class I recall
199910
200620
200810
200910
201010
201110
201210
201810
202110
202310
202410
FIG. 1 — Lineage of K982155, 1992–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MBI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MBI device

  1. #1 K203268 Arthrex FiberTak Suture Anchorscore 21.4 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K972622Straight-in Bone Screw Fixation System
Summary page 1
…from prostatectomy). The Short Shaft Straight-In Bone Screw Fixation System is substantially equivalent to Influence, Inc.’s Straight-In Bone Screw System cleared under K972622. The design and materials of the Short Shaft Straight-In and Straight-In systems are identical. The only difference is that the I…
Influence, Inc.1997—

Also cleared against K972622: 1 other device →

What descends from it? (12)

See all 12

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K053371Ams Male Transobturator Sling SystemAmerican Medical Systems, Inc.200610
K990095Straight-in-Orthopedic Bone Screw Fixation SystemInfluence, Inc.19990

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 6 years and passes through 2 companies; a new generation was cleared every 11 months on median.
  • 2 of the 7 ancestors have a recall of any class.
  • Of its descendants, K053371 (American Medical Systems, Inc., 2006) has gone furthest, with 10 descendants of its own.
  • 1 other device also cites its predicate K972622.

How does its category compare?

All MBI devices

MBI Fastener, Fixation, Nondegradable, Soft Tissue: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · MBI

27in 2025

2007: 162008: 102009: 192010: 172011: 302012: 242013: 312014: 232015: 232016: 172017: 172018: 162019: 312020: 352021: 182022: 192023: 522024: 222025: 272026 (partial year): 30
2007high 52 (2023) · low 10 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MBI

58in 2025

2007: 80 days median2008: 69 days median2009: 82 days median2010: 76 days median2011: 75 days median2012: 94 days median2013: 100 days median2014: 101 days median2015: 85 days median2016: 94 days median2017: 70 days median2018: 91 days median2019: 90 days median2020: 83 days median2021: 107 days median2022: 64 days median2023: 57 days median2024: 30 days median2025: 58 days median2026 (partial year): 63 days median
2007high 107 (2021) · low 30 (2024)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MBI

1in 2025

2007: 242008: 62009: 22010: 32011: 232012: 62013: 22017: 42018: 22020: 12023: 12024: 12025: 1
2007high 24 (2007) · low 0 (2014)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MBI

3,826in 2025

2007: 2402008: 3382009: 3552010: 2912011: 3282012: 3712013: 4422014: 5042015: 5072016: 7952017: 6752018: 1,0722019: 1,3032020: 1,4542021: 1,8902022: 1,5912023: 2,5032024: 3,7792025: 3,826
2007high 3,826 (2025) · low 240 (2007)2025

MAUDE reports naming product code MBI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007168024240
200810696338
200919822355
201017763291
2011307523328
201224946371
2013311002442
2014231010504
201523850507
201617940795
201717704675
2018169121,072
2019319001,303
2020358311,454
20211810701,890
2022196401,591
2023525712,503
2024223013,779
2025275813,826
202630630—

What is it indicated for?

The Short Shaft Straight-In Bone Screw Fixation System is intended for soft tissue fixation to bones in the pelvic region (e.g., pubic, sacral, etc.) by means of bone screws threaded with suture. It is indicated for use during open surgical procedures where soft tissue fixation to bones in the pelvic region is needed (e.g., bladder neck suspension and urethral sling procedures for female stress urinary incontinence resulting from urethral hypermobility and/or intrinsic sphincter deficiency, sling procedure for male stress urinary incontinence resulting from prostatectomy).

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K982155: Short Straight-in Bone Screw Fixation System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K982155

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026