510(k) Report

510(k) · Cleared

Recalled · Class I · 2016

Manual Resuscitator with Ace

K982215510(k) TraditionalCleared Sep 18, 199887-day reviewClass II21 CFR 868.5915Recalls 8 (2 Class I)

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Medical Marketing Concepts · BTM Ventilator, Emergency, Manual (Resuscitator)

Cleared on Sep 18, 1998 after an 87-day review. FDA’s file for it is a 510(k) statement, which names no predicate. It has a Class I recall. It has been recalled 8 times, including 2 Class I recalls.

Decided
Sep 18, 1998
Review
87 days
Class
Class II
Product code
BTM
Recalls
8 (2 Class I)
Predicates
0

FDA’s file for it is a 510(k) statement, which names no predicate.

FIG. 1 — Lineage of K982215Source: FDA 510(k) database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new BTM device

  1. #1 K243861 butterflyBVMscore 9.5 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (1 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Mar 15, 2016Class IIZ-1880-2016Process controlStat-check CO2 indicators are non-functional. The indicator is yellow when not in use and should be purple when not in use. The yellow indicates a 5% CO2 level, cardiac massage and ventiliation being performed correctly. The color will…
May 16, 2014Class IZ-1948-2014Process change controlThe pop-off valve in the defective devices remain open and a squeeze of the bag may not generate enough force to force the duck bill valve open and therefore no air will be delivered to the victim.
Jul 11, 2012Class IZ-0172-2013Component design/selectionPossible volume leakage through the inlet valve during compressions of the resuscitator bag.
Mar 26, 2004Not classifiedZ-0893-04OtherIn some cases the device may develop small cracks that could expand over time and result in reduced shelf life or other failure.
Mar 26, 2004Not classifiedZ-0895-04OtherIn some cases the device may develop small cracks that could expand over time and result in reduced shelf life or other failure.
Mar 26, 2004Not classifiedZ-0891-04OtherIn some cases the device may develop small cracks that could expand over time and result in reduced shelf life or other failure.
Mar 26, 2004Not classifiedZ-0892-04OtherIn some cases the device may develop small cracks that could expand over time and result in reduced shelf life or other failure.
Mar 26, 2004Not classifiedZ-0894-04OtherIn some cases the device may develop small cracks that could expand over time and result in reduced shelf life or other failure.

No ancestor or descendant has a Class I recall.

How does its category compare?

All BTM devices

BTM Ventilator, Emergency, Manual (Resuscitator): FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · BTM

2in 2025

2007: 22008: 32010: 22011: 22012: 12015: 12016: 12018: 22021: 12022: 12023: 12025: 22026 (partial year): 1
2007high 3 (2008) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · BTM

83in 2008

2008: 83 days median
2007high 83 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · BTM

9in 2024

2009: 232010: 32012: 13, 13 Class I2013: 3, 1 Class I2023: 92024: 9, 9 Class I2026 (partial year): 1, 1 Class I
2007high 23 (2009) · low 0 (2007)2026

Class I (24 since 2007) Class II/III not classified

Adverse event reports per year · BTM

36in 2025

2007: 652008: 312009: 212010: 232011: 482012: 692013: 442014: 1082015: 362016: 922017: 562018: 562019: 462020: 262021: 422022: 352023: 462024: 332025: 36
2007high 108 (2014) · low 21 (2009)2025

MAUDE reports naming product code BTM, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—065
2008383031
20090—2321
20102—323
20112—048
20121—13 (13)69
20130—3 (1)44
20140—0108
20151—036
20161—092
20170—056
20182—056
20190—046
20200—026
20211—042
20221—035
20231—946
20240—9 (9)33
20252—036
20261—1 (1)—

What is it indicated for?

Manual ventilation and assist in verification of endotracheal tube placement

Indications for use read by OCR from a scanned FDA 510(k) statement, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K982215: Manual Resuscitator with Ace.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K982215

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Page last updated Nov 3, 2026