510(k) · Cleared
ClearedMicroalbustix Reagent Strips
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Bayer Corp. · JIR Indicator Method, Protein Or Albumin (Urinary, Non-Quant.)
Cleared on Aug 12, 1998 after a 49-day review. The FDA summary names its predicate without a number.
- Decided
- Aug 12, 1998
- Review
- 49 days
- Class
- Class I
- Product code
- JIR
- Recalls
- None
- Predicates
- 0
The FDA summary names its predicate without a number.
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JIR? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new JIR device
- #1 K210069 Minuteful - kidney testscore 7.5 · 4 generations · no Class I recall
- #2 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | — | CLINITEK® Microalbumin Reagent Strips Named without a submission number | |
| * | — | Micral-Test® strips Named without a submission number |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
How does its category compare?
All JIR devicesJIR Indicator Method, Protein Or Albumin (Urinary, Non-Quant.): FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · JIR
1in 2023
2026 to Oct 25, outlined.
Median 510(k) review, days · JIR
Too few JIR 510(k)s in any year since 2007 to give a median.
Recalls per year · JIR
2so far in 2026, the most since 2007
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · JIR
2in 2025
MAUDE reports naming product code JIR, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 1 | — | 0 | 1 |
| 2008 | 0 | — | 0 | 0 |
| 2009 | 0 | — | 0 | 0 |
| 2010 | 0 | — | 0 | 1 |
| 2011 | 0 | — | 0 | 1 |
| 2012 | 0 | — | 0 | 0 |
| 2013 | 0 | — | 0 | 9 |
| 2014 | 0 | — | 0 | 0 |
| 2015 | 1 | — | 0 | 4 |
| 2016 | 0 | — | 0 | 5 |
| 2017 | 0 | — | 0 | 2 |
| 2018 | 0 | — | 0 | 0 |
| 2019 | 0 | — | 0 | 1 |
| 2020 | 0 | — | 0 | 2 |
| 2021 | 0 | — | 0 | 1 |
| 2022 | 1 | — | 0 | 0 |
| 2023 | 1 | — | 0 | 2 |
| 2024 | 0 | — | 0 | 4 |
| 2025 | 0 | — | 0 | 2 |
| 2026 | 0 | — | 2 | — |
What is it indicated for?
MICROALBUSTIX Reagent Strips are firm plastic strips that contain two reagent areas to test for small amounts of albumin in urine (microalbuminuria), creatinine in urine, and also determine the albumin-to-creatinine ratio in urine. The strips are read visually by comparing the color of the reacted strip to the color chart on the bottle label. MICROALBUSTIX Reagent Strips provide semi-quantitative results and can be used for screening urine specimens for microalbuminuria as an aid in the detection of persons at risk for developing kidney damage. MICROALBUSTIX Reagent Strips are for professional use.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K982219 · printed Nov 6, 2026
Cite this page
510(k) Report. “K982219: Microalbustix Reagent Strips.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K982219
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Page last updated Nov 3, 2026