510(k) Report

510(k) · Cleared

Cleared

Disetronic Penfine Injection Pen Needle

K982399510(k) TraditionalCleared Aug 6, 199827-day reviewClass II21 CFR 880.5570

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Disetronic Medical Systems · FMI Needle, Hypodermic, Single Lumen

Cleared on Aug 6, 1998 as substantially equivalent to K973339 (Disetronic Medical Systems, 1997) and 1 other predicate after a 27-day review. Its family tree reaches back 1 generation to 1997. 18 later devices descend from it.

Decided
Aug 6, 1998
Review
27 days
Class
Class II
Product code
FMI
Recalls
None
Predicates
2

Its longest line of descent runs back 1 generation to K970737 (1997). 2 ancestors in all. 18 later devices descend from it, 2 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1997: 1 other ancestor2001: 1 descendant cleared1999: 1 descendant cleared2010: 2 descendants cleared2012: 3 descendants cleared2013: 2 descendants cleared2015: 2 descendants cleared2019: 1 descendant cleared2022: 4 descendants cleared2020: 1 descendant cleared2026: 1 descendant clearedK970737 · B-D Ultra-Fine II Short 31G X 5/16 Pen Needle · Bd Becton Dickinson Vacutainer Systems Preanalytic · 19971995200020052010201520202025
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor 1 generation forward: 2 descendants2 generations forward: 2 descendants3 generations forward: 3 descendants4 generations forward: 2 descendants5 generations forward: 2 descendants6 generations forward: 2 descendants7 generations forward: 4 descendants8 generations forward: 1 descendant K970737 · B-D Ultra-Fine II Short 31G X 5/16 Pen Needle · Bd Becton Dickinson Vacutainer Systems Preanalytic · 19970+5
  1. Root · 1 generation backK970737 B-D Ultra-Fine II Short 31G X 5/16 Pen NeedleBd Becton Dickinson Vacutainer Systems Preanalytic · 1997
  2. This deviceK982399 Disetronic Penfine Injection Pen NeedleDisetronic Medical Systems · 1998
  3. Descendant · cites it directly · 17 of its ownK994197 Disentronic Penfine Injection Pen NeedleDisetronic Medical Systems · 1999
  4. Descendant · 2 generations on · 13 of its ownK102108 Clickfine Pen NeedleYpsomed AG · 2010
  5. Descendant · 3 generations on · 9 of its ownK110312 Clickfine Autoprotect Pen NeedleYpsomed AG · 2012
  6. Descendant · 4 generations on · 8 of its ownK131123 Clickfine Autoprotect Pen NeedleYpsomed AG · 2013
  7. Descendant · 5 generations on · 7 of its ownK152514 Clickfine AutoProtect Pen NeedleYpsomed AG · 2015

Showing 5 of 18 descendants. See all descendants

Descendants cleared per year

1999: 12001: 12010: 22012: 32013: 22015: 22019: 12020: 12022: 42026: 1
1999high 4 (2022) · low 0 (2000)2026

Most influential descendants

Showing 5 of 18 · See all
  • K994197Disentronic Penfine Injection Pen NeedleDisetronic Medical Systems · 1999 · cites it directly17descendants
  • K102108Clickfine Pen NeedleYpsomed AG · 2010 · 2 generations on13descendants
  • K110312Clickfine Autoprotect Pen NeedleYpsomed AG · 2012 · 3 generations on9descendants
  • K131123Clickfine Autoprotect Pen NeedleYpsomed AG · 2013 · 4 generations on8descendants
  • K152514Clickfine AutoProtect Pen NeedleYpsomed AG · 2015 · 5 generations on7descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K970737B-D Ultra-Fine II Short 31G X 5/16 Pen NeedleBd Becton Dickinson Vacutainer Systems Preanalytic1997—
0 (this device)K982399Disetronic Penfine Injection Pen NeedleDisetronic Medical Systems1998—
+1K994197Disentronic Penfine Injection Pen NeedleDisetronic Medical Systems1999—
+2K102108Clickfine Pen NeedleYpsomed AG2010—
+3K110312Clickfine Autoprotect Pen NeedleYpsomed AG2012—
+4K131123Clickfine Autoprotect Pen NeedleYpsomed AG2013—
+5K152514Clickfine AutoProtect Pen NeedleYpsomed AG2015—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199710

Descendants by year cleared

Year clearedDevicesWith a Class I recall
199910
200110
201020
201230
201320
201520
201910
202010
202240
202610
FIG. 1 — Lineage of K982399, 1997–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FMI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FMI device

  1. #1 K252886 Pen Needlescore 14.5 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K973339Disetronic Penfine Injection Pen Needle
Summary page 1
…ly Marketed Devices The 31 gauge Disetronic PenFine® Injection Pen Needles are substantially equivalent to the 29 and 30 gauge Disetronic PenFine® injection Pen Needies (K973339) and the Becton Dickinson B- ' D Ultra-Fine Il Injection Pen Needles (K970737). 8.5 Device Description The 31 gauge Disetronic…
Disetronic Medical Systems1997—
*K970737B-D Ultra-Fine II Short 31G X 5/16 Pen Needle
Summary page 1
…substantially equivalent to the 29 and 30 gauge Disetronic PenFine® injection Pen Needies (K973339) and the Becton Dickinson B- ' D Ultra-Fine Il Injection Pen Needles (K970737). 8.5 Device Description The 31 gauge Disetronic PenFine® Injection Pen Needles are the same sterile, non-pyrogenic, singie use…
Bd Becton Dickinson Vacutainer Systems Preanalytic1997—

What descends from it? (18)

See all 18

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K994197Disentronic Penfine Injection Pen NeedleDisetronic Medical Systems199917
K013782Disetronic Penfine Insulin Injection Pen NeedleDisetronic Medical Systems20014

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • None of the 2 ancestors has a recall.
  • Of its descendants, K994197 (Disetronic Medical Systems, 1999) has gone furthest, with 17 descendants of its own.

How does its category compare?

All FMI devices

FMI Needle, Hypodermic, Single Lumen: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · FMI

11in 2025

2007: 152008: 102009: 72010: 152011: 122012: 172013: 112014: 142015: 102016: 202017: 92018: 202019: 122020: 112021: 182022: 232023: 182024: 32025: 112026 (partial year): 12
2007high 23 (2022) · low 3 (2024)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FMI

141in 2025

2007: 71 days median2008: 85 days median2009: 177 days median2010: 119 days median2011: 113 days median2012: 107 days median2013: 87 days median2014: 155 days median2015: 89 days median2016: 217 days median2017: 253 days median2018: 176 days median2019: 186 days median2020: 263 days median2021: 143 days median2022: 189 days median2023: 112 days median2024: 90 days median2025: 141 days median2026 (partial year): 119 days median
2007high 263 (2020) · low 71 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FMI

1in 2024

2007: 22008: 42009: 32010: 792011: 52012: 12013: 12014: 32015: 12017: 162019: 52020: 32021: 72023: 22024: 12026 (partial year): 1, 1 Class I
2007high 79 (2010) · low 0 (2016)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · FMI

2,424in 2025

2007: 2082008: 1772009: 2632010: 2492011: 2402012: 2152013: 2552014: 2872015: 5672016: 9412017: 1,5472018: 2,3982019: 4,8962020: 4,2452021: 4,5322022: 4,8852023: 4,9862024: 4,0532025: 2,424
2007high 4,986 (2023) · low 177 (2008)2025

MAUDE reports naming product code FMI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200715712208
200810854177
200971773263
20101511979249
2011121135240
2012171071215
201311871255
2014141553287
201510891567
2016202170941
20179253161,547
20182017602,398
20191218654,896
20201126334,245
20211814374,532
20222318904,885
20231811224,986
202439014,053
20251114102,424
2026121191 (1)—

What is it indicated for?

The Disetronic PenFine® Injection Pen Needles are intended for the hypodermic injection of fluids into the body when attached to an injector pen.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K982399: Disetronic Penfine Injection Pen Needle.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K982399

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026