510(k) · Cleared
ClearedCoda MPX30 Motion Analysis System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Pinsco Inc. Dba B & L Engineering · LXJ Interactive Rehabilitation Exercise Devices
Cleared on Oct 7, 1998 as substantially equivalent to K890076 (Motion Analysis Corp., 1989) after an 86-day review. Its family tree reaches back 1 generation to 1989. 13 later devices descend from it.
- Decided
- Oct 7, 1998
- Review
- 86 days
- Class
- Class II
- Product code
- LXJ
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 1 generation to K890076 (1989). 13 later devices descend from it, 2 citing it directly.
- Root · 1 generation backK890076 OrthotrakMotion Analysis Corp. · 1989
- This deviceK982425 Coda MPX30 Motion Analysis SystemPinsco Inc. Dba B & L Engineering · 1998
- Descendant · cites it directly · 10 of its ownK033514 Coda CX1 Motion Analysis SystemCharnwood Dynamics, Ltd. · 2004
- Descendant · cites it directly · 10 of its ownK030714 Peak MotusPeak Performance Technologies, Inc. · 2003
- Descendant · 2 generations on · 6 of its ownK130847 Jintronix Rehabilitation System (JRS)Jintronix, Inc. · 2014
- Descendant · 3 generations on · 1 of its ownK151446 Recovr Rehabilitation SystemRecovr,Inc · 2015
- Descendant · 2 generations on · 1 of its ownK131660 Smart (Smart-D, Smart-DX)Bts S.P.A. · 2014
Showing 5 of 13 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 13 · See all- K033514Coda CX1 Motion Analysis SystemCharnwood Dynamics, Ltd. · 2004 · cites it directly10descendants
- K030714Peak MotusPeak Performance Technologies, Inc. · 2003 · cites it directly10descendants
- K130847Jintronix Rehabilitation System (JRS)Jintronix, Inc. · 2014 · 2 generations on6descendants
- K151446Recovr Rehabilitation SystemRecovr,Inc · 2015 · 3 generations on1descendant
- K131660Smart (Smart-D, Smart-DX)Bts S.P.A. · 2014 · 2 generations on1descendant
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K890076 | Orthotrak | Motion Analysis Corp. | 1989 | — |
| 0 (this device) | K982425 | Coda MPX30 Motion Analysis System | Pinsco Inc. Dba B & L Engineering | 1998 | — |
| +1 | K033514 | Coda CX1 Motion Analysis System | Charnwood Dynamics, Ltd. | 2004 | — |
| +1 | K030714 | Peak Motus | Peak Performance Technologies, Inc. | 2003 | — |
| +2 | K130847 | Jintronix Rehabilitation System (JRS) | Jintronix, Inc. | 2014 | — |
| +3 | K151446 | Recovr Rehabilitation System | Recovr,Inc | 2015 | — |
| +2 | K131660 | Smart (Smart-D, Smart-DX) | Bts S.P.A. | 2014 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2003 | 1 | 0 |
| 2004 | 1 | 0 |
| 2009 | 1 | 0 |
| 2014 | 2 | 0 |
| 2015 | 3 | 0 |
| 2016 | 1 | 0 |
| 2017 | 1 | 0 |
| 2018 | 2 | 0 |
| 2019 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LXJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K890076 | OrthotrakSummary page 1…em 6. Common Name: Motion Analysis System 7. Classification Name: System / Optical Position / Movement Recording 8. Identification of Predicate Device(s): OrthoTrak IT (K 890076) 9. Device Description: CODA mpx30 is an optical/electronic system which measures and analyses the 3D position and movement of m… | 1989 |
What descends from it? (13)
See all 132 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Its one ancestor has no recall.
- Of its descendants, K033514 (Charnwood Dynamics, Ltd., 2004) has gone furthest, with 10 descendants of its own.
How does its category compare?
All LXJ devicesLXJ Interactive Rehabilitation Exercise Devices: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · LXJ
3in 2019
2026 to Oct 25, outlined.
Median 510(k) review, days · LXJ
224in 2019
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LXJ
No recall names LXJ since 2007.
Adverse event reports per year · LXJ
1in 2018
MAUDE reports naming product code LXJ, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 0 | — | 0 | 0 |
| 2009 | 1 | — | 0 | 0 |
| 2010 | 0 | — | 0 | 0 |
| 2011 | 0 | — | 0 | 0 |
| 2012 | 0 | — | 0 | 0 |
| 2013 | 0 | — | 0 | 0 |
| 2014 | 2 | — | 0 | 0 |
| 2015 | 3 | 182 | 0 | 0 |
| 2016 | 1 | — | 0 | 0 |
| 2017 | 2 | — | 0 | 0 |
| 2018 | 3 | 231 | 0 | 1 |
| 2019 | 3 | 224 | 0 | 0 |
| 2020 | 0 | — | 0 | 0 |
| 2021 | 0 | — | 0 | 0 |
| 2022 | 0 | — | 0 | 0 |
| 2023 | 0 | — | 0 | 0 |
| 2024 | 0 | — | 0 | 0 |
| 2025 | 0 | — | 0 | 0 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
The Coda mpx30 system has general application to measurement and recording of 3D position and movement, including human movement. It is appropriate for use in assessment of the 3D motion of the limbs and body of patients who have some impairment of movement functions of either a neurological or orthopaedic cause.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K982425 · printed Nov 3, 2026
Cite this page
510(k) Report. “K982425: Coda MPX30 Motion Analysis System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K982425
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026