CCA-220

K982441510(k) TraditionalCleared Oct 9, 199887-day reviewClass II21 CFR 874.1050

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Benson Medical Instruments Co. · EWO Audiometer

Cleared on Oct 9, 1998 after an 87-day review. FDA’s file for it is a 510(k) statement, which names no predicate.

Decided
Oct 9, 1998
Review
87 days
Class
Class II
Product code
EWO
Recalls
None
Predicates
0

FDA’s file for it is a 510(k) statement, which names no predicate.

FIG. 1 — Lineage of K982441Source: FDA 510(k) database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in EWO? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new EWO device

  1. #1 K234095 OtoNova/OtoNova Proscore 9.4 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

How does its category compare?

All EWO devices

EWO Audiometer: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · EWO

2in 2024

2007: 52008: 12009: 22010: 22011: 32012: 42013: 22014: 12015: 42017: 22018: 22019: 12022: 12023: 12024: 2
2007high 5 (2007) · low 0 (2016)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · EWO

173in 2015

2007: 69 days median2011: 151 days median2012: 137 days median2015: 173 days median
2007high 173 (2015) · low 69 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · EWO

4in 2023

2008: 12023: 4
2007high 4 (2023) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · EWO

13in 2025

2007: 12008: 12009: 12010: 42011: 22015: 12019: 62020: 72021: 32022: 62023: 32024: 22025: 13
2007high 13 (2025) · low 0 (2012)2025

MAUDE reports naming product code EWO, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200756901
20081—11
20092—01
20102—04
2011315102
2012413700
20132—00
20141—00
2015417301
20160—00
20172—00
20182—00
20191—06
20200—07
20210—03
20221—06
20231—43
20242—02
20250—013
20260—0—

What is it indicated for?

The CCA-220 Audiometer is an air-conduction audiometer designed to provide automatic hearing testing. A series of tones is presented by the CCA-220 through a Telephonics TDH-39 headset. The test subject then presses a hand switch to indicate to the CCA-200 that the tone has been heard. The CCA-220 proceeds with the hearing testing, and records the subject's responses. The resultant test data are available to print on an integral printer or to store in…

Read the full statement (195 words)

The CCA-220 Audiometer is an air-conduction audiometer designed to provide automatic hearing testing. A series of tones is presented by the CCA-220 through a Telephonics TDH-39 headset. The test subject then presses a hand switch to indicate to the CCA-200 that the tone has been heard. The CCA-220 proceeds with the hearing testing, and records the subject's responses. The resultant test data are available to print on an integral printer or to store in the CCA-220's hard drive.

The CCA-220 has an integral computer which provides all of the capabilities of the instrument. The instrument's display panel shows the setup and control screens that are used to perform the test functions. The instrument is based on an integral PC compatible computer with a Pentium processor, running the operating system of Microsoft Windows 95. Control of the CCA-220 is handled by selecting the desired test elements on the touch screen monitor. The instrument also incorporates an internal printer for printing test results.

The CCA-220 has a range of options for both computer interfacing and automatic testing, such as error detection and multilingual voice instruction. These options are selected using the setup screen on the touch-screen monitor.

Indications for use read by OCR from a scanned FDA 510(k) statement, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K982441: CCA-220.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K982441

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Page last updated Nov 3, 2026